PVC insulated and sheathed power cable 0.6/1kV (unarmoured type)
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
500mm Power cable with single and Multi-core PVC Insulated and sheath 0.6/1kV
It applies to electrical power transmission and distribution lines with AC rated voltage Uo/U up to and including 0.6/1kV. For outdoor and indoor installation in damp and wet locations, laid directly in the ground (when well protected in ducts, in trenches and in steel support brackets).
Voltage rating: 0.6/1kV
Standard applied: IEC60502, BS7889, GB/T12706
Max. working temp.: 90°C, can be 110°C as per requirement
Max. Short-circuit temperature of the conductor shall not be exceeding 250°C (Max. sustaing period not exceeding 5S)
Conductor: Class 1/2 annealed bare copper solid or strands
Insulation: PVC
Outer sheath: PVC
Cores: 1C, 2C, 3C,4C,5C, 3C+1E,4C+1E,3C+2E
Cross section area: 1.5 ~ 630 sqmm
Color: Black or as per requirement
Bending radius: Not less than 15 times of the cable's OD
Test voltage: 3.5kV/5min
Packing: Wooden drum or as per requirement
Certification: ISO9001/ISO14001/OHSMS18001/CE/CB/CCC/SAA
OEM: Available
BDK cables has very good sales over the world, enjoying a very good reputation based on top quality and most competitive price and best service.
Remark: The cable can be of flame retardance, fire resistance and environment friendly or other property
Parameter sheet
Main manufacturing procedure
Copper wire drawing and annealing
Copper wire stranding
PVC insulation extruding
Cores twisting
Outer sheath extruding and labelling
Spooling
Main Quality Inspection Equipment
Sparker tester,Heating aging Chamber,High resistance machine, Oxygen index equipment, Partial ischarge inspection instruments, Fireproof testing device,High-power voltage withstand tester,No-rotor Vulkameter,Pull tester,Analytical balance,Direct current bridge,Plastic tester,Projector, Punch machine,Cross-linked cutting machine,etc.
Company Overview
Certificates
- Q: My car's stock stereo is pretty low power, probably less than 20 watts. I would like to replace the power wires with better ones, if not for any real benefit to sound quality then simply to satisfy a personal whim. 8 gauge wires would be too I think for the small spaces. Anyway, would a good quality speaker wire work just a good as a power wire of the same gauge?
- Yup, Power Wires and Speaker Wires... are simply coppper wires @ different guages. I've used speaker wires to draw power from the battery, to power a Sat Radio. Just make sure you add the correct fuse. You have to factor in two things to choose which gauge to use, amperage and distance.
- Q: What is the difference between an ordinary power cable for a dedicated cable?
- Inverter special cable General power cable difference shielding requirements higher, the number of cores is generally 3 +. three lines of the ground line of three symmetrical and phase line intersection. Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on. The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.
- Q: I have just bought the above SSD product and don't know what connection I need for power, I have a SATA cable but the other long slot doesn't fit any of my power adapters, what do I need?
- You can use splitters.
- Q: What is the safe carrying capacity of the power cable YJV22-10KV-3 * 400?
- Power cable YJV22-10KV-3 * 400 safe carrying capacity: in the air deposited capacity of 565A, buried 520A.
- Q: Hello guyzz, recently i have bought new card powercolor radeon hd 6770 1gb gddr5 .i installed it but it required a 6 pin power cable forbut i checked in my all pc..i cant fine any 6 pin power cable.so without any cable its not working wat i do plzzz help.......
- There okorder /... 2. Buy new Power Supply at least 450 Watt. ( I suggest it because that graphics card requires a strong source of power) * if your Power Supply is powerful, sufficient only buy VGA Power Adapter ~hope it help~
- Q: I know there is problem in the CPU, please suggest what is the problem and how much it is going to cost me?
- Power cable into CPU? I guess you must possibly still have some of those dual power connector Power Supply? Those one where you can connect both the Power to the monitor and the input power to the CPU? If this is the case, your Power supply is possibly dying slowly. You need to change the poer supply. However, if that is not the kind of power supply that you have, I guess what you are pssibly talking about is that your monitor data communication cable which you connect to the CPU so that the data can be transmitted through to your monitor? If this is the case, then your monitor is not having any problem, it is just responding to the fact that it is properrly connected. Put on your system and see if your monitor do come on... If it comes on then everything is fine.... Now finally, if all these is not the case, then it mean you have not put your question properly. Rephrase your question so that you can have an answer... except ofcourse you are just trying to fool around...
- Q: Basically i want to add another ssd using a power splitter cable, however i was wondering if you could use the power splitter cable with the optical drive instead of with the current hard drive, (im asking this as there's no room to place the ssd drive close to the hard drive)Thanks
- Yes it will work just fine.
- Q: I have been given a Toshiba flat screen tv - the product type is 20VL44G however the power cable has been lost. Does anyone know where I can get a replacement from as I have Googled this and cannot find anything? I am in the UK, thank you all.
- check the specs on the back of the tv. There could be some listings such as vdc or volts... or something like/close if not 20-Zoll/51cm call a tv repair person. but now that I'm looking at a pic of this square tele... are you sure that it isn't a self-powered tv?
- Q: Power cable casing buried what are the requirements
- 1 It is advisable to select the route to lay the cable in a suitable way: 1 Avoid the area where the corrosion of the acid, alkali, or stray current is seriously affected by electrochemical corrosion
- Q: i am hooking up my system tomorow and im really not sure where to drill a hole in the firewall to run my 4 AWG cable any suggestions any pictures would be helpful thanks!
- Check first for any factory made holes that are not in use or have extra space to be used. If you are explorer is anything like my Taurus I would say somewhere near where your steering wheel connects to the firewall. But it will be kinda risky around that area since you would have to be careful for your power steering.
Send your message to us