PVC insulated and sheathed power cable 0.6/1kV (unarmoured type)
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
500mm Power cable with single and Multi-core PVC Insulated and sheath 0.6/1kV
It applies to electrical power transmission and distribution lines with AC rated voltage Uo/U up to and including 0.6/1kV. For outdoor and indoor installation in damp and wet locations, laid directly in the ground (when well protected in ducts, in trenches and in steel support brackets).
Voltage rating: 0.6/1kV
Standard applied: IEC60502, BS7889, GB/T12706
Max. working temp.: 90°C, can be 110°C as per requirement
Max. Short-circuit temperature of the conductor shall not be exceeding 250°C (Max. sustaing period not exceeding 5S)
Conductor: Class 1/2 annealed bare copper solid or strands
Insulation: PVC
Outer sheath: PVC
Cores: 1C, 2C, 3C,4C,5C, 3C+1E,4C+1E,3C+2E
Cross section area: 1.5 ~ 630 sqmm
Color: Black or as per requirement
Bending radius: Not less than 15 times of the cable's OD
Test voltage: 3.5kV/5min
Packing: Wooden drum or as per requirement
Certification: ISO9001/ISO14001/OHSMS18001/CE/CB/CCC/SAA
OEM: Available
BDK cables has very good sales over the world, enjoying a very good reputation based on top quality and most competitive price and best service.
Remark: The cable can be of flame retardance, fire resistance and environment friendly or other property
Parameter sheet
Main manufacturing procedure
Copper wire drawing and annealing
Copper wire stranding
PVC insulation extruding
Cores twisting
Outer sheath extruding and labelling
Spooling
Main Quality Inspection Equipment
Sparker tester,Heating aging Chamber,High resistance machine, Oxygen index equipment, Partial ischarge inspection instruments, Fireproof testing device,High-power voltage withstand tester,No-rotor Vulkameter,Pull tester,Analytical balance,Direct current bridge,Plastic tester,Projector, Punch machine,Cross-linked cutting machine,etc.
Company Overview
Certificates
- Q: VV3 * 120 + 2 * 70 cable what does it mean
- YJV cable is cross-linked polyethylene insulation, VV cable is PVC insulation, the former temperature level higher than the latter, such as the former conductor temperature can be 90 degrees, while the latter can only to 70 degrees!
- Q: Cable yjv-0.6 / 1kv-4 * 120 + 1 * 70 What does it mean?
- Cable trench as a power construction project should be cable trench construction construction design, cable trench construction program, according to the previous design requirements and programs in order to develop cable trench construction quality acceptance procedures
- Q: Doesn't have to be super powerful, just lifting about 100 pounds, frequently. I've already looked at the normal places, and they are all DC powered (car battery). I suppose it could also be manual.
- With no offense to answer 1, but in agreement with answer 2, ONLY through experience with both big LOT outlets; I'd probably try Northern first. In fact I just had a discussion with someone yesterday comparing the two; but again; it's personal preference. It's likely they get their inventory from the same distributors. For 100 pounds, and if geared at all, manual could be fine. One issue might be your intended use; portability; possible access OR NOT, to a power source; etc.
- Q: I am trying to hook up a LCD display (CPU Temp, USB's in use, Memory Temp/usage, etc) and It came with a 5pin DIN connector for what I assume is the power. I am not sure what I need to do to connect it to the PSU. Any help or ideas?
- I think this device should have a power connector as well as a sensor cable (USB in use should have a connector running on to your motherboard.) can you provide me the make/mode number of the equipment. Also provide me with a link so that i could see the connectors and wires and the device. Else take a pic, upload it some image hosting site and provide with a link. (you can edit your question or add additional info and provide a link. Replace the
- Q: I looked on 3 of my friends plus mine and looked at the cord that comes from the big block power supply thing for the xbox 360 and every one of them looked differant. Why is that?
- so when they brake u cant but cheaper replacements . you have to buy the real thing so they make more money
- Q: I dont get any power to my amp. If something is pinching the line could that make it not get any power? Or could there be something else wrong?
- i would also check ur ground wire.no power means 2 things power wire not secure or the ground is not connected right
- Q: I'm installing my car audio system in the morning. I have a 650w 4 channel amp for my four interior speakers and a class D monoblock amp for my sub.I have an 8awg wiring kit. If I split that to use it on both amps, it would end up at 16awg going to the amps. Is this thick enough for my setup?
- 1. We can't answer without knowing more about your amplifiers. 650w 4 channel doesn't tell us anything useful, because the power rating may be a peak number that's only good for marketing, and you didn't tell us anything about the monoblock amplifier at all. Give us brand and model numbers and we might be able to help. 2. If I split that to use it on both amps, it would end up at 16awg going to the amps ....no. That's now how it works. (I'm not sure how you envision splitting the wire to make two wires that are half the size; are you cutting it down the middle with a razor?) You can use a distribution block to connect both amplifiers to the same main power wire, but you don't have to go to a smaller wire out of the d-block: you can run 8-gauge wire from the battery to the distribution block, then more 8-gauge from the d-block to each amp. 3. Even if you did cut the 8-gauge wire in half, a wire half the size of 8-gauge isn't 16-gauge. It's 11-gauge. If you put six 16-gauge wires together, you'd get a wire that's a little smaller than 8-gauge. Please edit your question with the brand and model numbers of both amplifier, along with the estimated length of the wire run (ie, how many feet of wire do you need to go between the amps and the battery?) Then we can tell you what gauge wire you need. Edit: thanks for the update. Based on the information about your amplifiers, I don't think you should run both of them from the single 8-gauge wire. I'd switch to a 4-gauge dual amp kit, or you can buy a second 8-gauge kit and run each amp with its own power wire to the battery rather than sharing a single wire.
- Q: Physically, I want to know what the cable looks like around the part that plugs into the laptop. I have a kink in the cable around that point, but don't know if cutting it and soldering is an option, depending on how complicated that part of the cable is. The rest of the cable is really simple (positive and negative) but does it get complex at the end?Note: I'm only talking about the cable, not the laptop jack itself. I'm talking about the end farthest away from the brick, that plugs into the laptop. I wanna know what that looks like, and how easy it would be to repair.
- If that is what you are trying to do,. just make sure you get one of the same size. =] EDIT: hour:32 minutes: OK!!! Then there should be no problem. Just cut the cable and solder it again. ie. lets say this is the cable: END__DAMAGE HERE_____Start Cut whre its damaged and solder it. You shold get somethng ike this: END___________Start =]
- Q: we need to feed power of 60kW to island villa
- the current will be about 87 Amps.You can use 3ph,4 or3 1/2 core, 400V,35 sq mm copper marine cable
- Q: So I use my laptop with power and only put in the battery when I take it around. So I sat my computer down and it abruptly just shut down. I powered it on and I set it down again and the same thing happened. The third time it went all the way to the desk top. I touched and moved around the power cable connected to it shut down. WTF