Permanent Magnet Water Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:
1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,
2.It's apply to Chemical liquid(acid or alkali) transportation.
3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:
1. Model :MP
2.Pump Material:F-GFRPP A-CPVC P-CFRPVDF E-CFRETFE
3.Power:203-45W 204-65W 255-90W 257-150W 258-260W
4.Connection Type of inlet/outlet :S-screw type H- Straight pipe type
5.Pump spindle:C-CERAMIC T-TITANIUM(Ti) S-SIC
6.Rubber Material :E-EPDM V-VITON
7.Frequency :5-50Hz 6-60Hz
8.Voltage :V11-110V/220V/1ø V38-220V/380V/3 ø
- Q: Working principle and diagram of axial piston pump with pressure compensation variable
- Working principleThe main part (see section structure) the transmission shaft drives the rotating cylinder, the plunger seven uniform distribution on the cylinder to rotate around the shaft center line through the center of the spring will be slippery boots column components in the variable pressure in the head (or swash plate). In this way, with the rotation of the plunger cylinder for reciprocating motion complete, oil absorption and oil pressure action.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q: How does the centrifugal pump pump and cut the pump?
- Turn on the motor, observe the motor current, turn from high to low, observe the pump outlet pressure, and the pressure rise;Slowly open the outlet valve, so that the pressure drop slowly, the current slowly rising to the stable, the outlet valve to the maximum;Check the pump operation, stuffing box leakage, current, whether or not the rated current, motor, bearing temperature is normal, whether or not abnormal sound.
- Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
- Q: Suction stroke and lift of water pump
- The absorption process is also called the "largest self-priming height" (also can be understood as "the degree of self suction). Micro pumps do not add water at the circumstances, can automatically water suction pump up the maximum height (the vertical distance from the pump to be pumped from the mouth of pumping liquid).Generally lower than the water pump positioned equal when there is self-priming pump required capacity. For example, outdoor tourism, need to extract the water in the river, with the best micro pump self-priming ability (impossible to people ran to the river water inlet pipe with water. It) or pumping the liquid corrosion, easy to add water and so on occasions.
- Q: What is a feed pump?
- In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
- Q: What is the difference between the ground pump and the pump in the commercial concrete?
- What you should say here is the concrete pump.Ground pump: the pump will be placed in a position on the site, the pipeline will be sent to the construction of concrete surface,
- Q: What is the cause of the damage of pump bearings?
- Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
- Q: Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
- Submersible pump is best in the water, if dry pumping will cause burns.
- Q: How to maintain and repair the booster pump of pipeline pump?
- Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.
Send your message to us
Permanent Magnet Water Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords