Permanent Magnet Water Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:
1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,
2.It's apply to Chemical liquid(acid or alkali) transportation.
3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:
1. Model :MP
2.Pump Material:F-GFRPP A-CPVC P-CFRPVDF E-CFRETFE
3.Power:203-45W 204-65W 255-90W 257-150W 258-260W
4.Connection Type of inlet/outlet :S-screw type H- Straight pipe type
5.Pump spindle:C-CERAMIC T-TITANIUM(Ti) S-SIC
6.Rubber Material :E-EPDM V-VITON
7.Frequency :5-50Hz 6-60Hz
8.Voltage :V11-110V/220V/1ø V38-220V/380V/3 ø
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q: What are the ways of hydraulic pumps?
- Hydraulic pump is a power component of hydraulic system. It is driven by an engine or an electric motor. It draws oil from the hydraulic tank to form a component of the pressure oil which is sent to the actuating element.
- Q: What is the pump, how to classify, mainly used in where?
- 2. other classification of pumpsThe pump can be divided into two parts according to the position of the pump shaft:1) vertical pump2) horizontal pumpDivided by the number of suction ports:1) single suction pump (single suction pump);2) double suction pump (double, suction, pump)According to the prime mover of the drive pump:1) electric pumps2) steam turbine pump3) diesel engine pump[other details]
- Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
- 1. submersible pumpsA very wide range of water treatment tools. Unlike ordinary water pumps, it works underwater, while the pump works mostly on the ground.The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.Basic parameters of submersible pumpIncluding flow, lift, pump speed, matching power, rated current, efficiency, diameter and so onSubmersible pump main application and scope of applicationIncluding construction, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on
- Q: Why should I pump the pump before starting the centrifugal pump?
- Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.
- Q: Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
- Then control the speed level, to achieve the purpose of regulating the speed and flow of the feed water pump.
- Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
- First of all, the performance curve of the centrifugal pump is similar to the track of the train, and the train can not run away from the track.Secondly, the performance curves of centrifugal pump mainly include flow head curve, efficiency flow curve, power flow curve. When the pump is ready, the curve is fixed. In practical application, after determining the flow rate, the corresponding lift head, efficiency and power (relative to density) are determined. General requirements for centrifugal pump operating in the vicinity at the highest point of efficiency, the efficiency of the flow curve is similar to parabola, so if the actual operation condition deviated from the rated point, whether large or small, will cause the decline in pump efficiency (generally rated value is less than 15%), increased operating costs.
- Q: Hydraulic pump displacement refers to the pump shaft what?
- Displacement of the hydraulic pump refers to the axis of each turn, the volume discharged, called displacement, the unit is ml (ML),
- Q: How accurate is the metering pump?
- In addition, when the oil supply is too large or the pipeline pressure rises unexpectedly, the volume of the liquid in the hydraulic chamber can be changed, thereby affecting the stability of the flow and reducing the metering accuracy of the pump. In order to solve the problem of how to stabilize the measurement accuracy of metering pump metering pump flow, how stable, the three valve device. The so-called actual refers to the combination of three functions including compensation, discharge and safety protection device or device supporting the hydraulic chamber, according to its action principle is different, is divided into automatic compensation and forced compensation two three valve device.
- Q: What does "dual purpose" of water pump mean? Please expert advice
- 2, the pump must pay attention to maintenance after use, for example, when the pump is used up, the water pump should be put clean, it is best to remove the water pipe, and then rinse with water.5, the water pump on the tape should be removed, and then rinse with water after drying in the light place, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.6, to carefully check whether there are cracks in the impeller, the impeller fixed to the bearing on whether there is loose, cracks and loose if the phenomenon to be timely maintenance, if the water pump impeller should also be above the earth clean.