Specifications
Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:
1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,
2.It's apply to Chemical liquid(acid or alkali) transportation.
3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:
1. Model :MP
2.Pump Material:F-GFRPP A-CPVC P-CFRPVDF E-CFRETFE
3.Power:203-45W 204-65W 255-90W 257-150W 258-260W
4.Connection Type of inlet/outlet :S-screw type H- Straight pipe type
5.Pump spindle:C-CERAMIC T-TITANIUM(Ti) S-SIC
6.Rubber Material :E-EPDM V-VITON
7.Frequency :5-50Hz 6-60Hz
8.Voltage :V11-110V/220V/1ø V38-220V/380V/3 ø
- Q: What is the minimum continuous flow of a pump?
- At'-- the allowable temperature rise of pumping medium,C- pumping medium specific heat, kj/ (kg DEG C);Ho- off dead center lift, M.Minimum continuous flow minimum continuous stable flow and minimum continuous thermal flow and the maximum value in the selection, or use the pump process, the minimum continuous flow process requirements must be greater than the minimum flow rate of the pump, otherwise it will cause the pump cavitation, vibration and noise, so that the pump parts damaged. If the minimum continuous flow the pump can not meet the minimum requirement's process, can install the bypass reflux device or reflux system in the pump pipeline, to ensure that the minimum continuous flow pump.
- Q: Variable flow pumps are variable pumps
- Variable input speed, the pump out of the flow is variable, it can not be said that it is variable pump.In a word。 A variable pump is a variable displacement pump.
- Q: What does "anti pump" mean in pump operation?
- The pump again is the pump, the theory is the plugging problem can be solved, but if you are against the pump after pump has been plugging serious, and pump has been unable to solve the plugging problem, finally the worst solution is a split pipe, if the situation under enormous pressure will only exacerbate the plugging
- Q: What is cavitation, centrifugal pump cavitation phenomenon how to solve?
- First, what is cavitation?:When the centrifugal pump shell has air, it produces less centrifugal force because the density of the air is much smaller than the density of the liquid. Thus, suction pressure at the entrance to the top of the tank liquid level and pump is bad enough to the liquid storage tank into the pump, the centrifugal pump self suction capability, the centrifugal pump can not transport liquid, this phenomenon is called "cavitation".When a liquid drops at a certain temperature to the vapor pressure at that temperature, the liquid produces a bubble. The phenomenon of producing bubbles is called cavitation. When the cavitation bubbles, flow to the high pressure, the volume of reduced, so as to burst. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse.
- Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
- If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
- Q: The distance from the pump button to the ground
- A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
- Q: What's the meaning of the pump head in the water pump, please advise, thank you
- In general, the pump removes the motor, and all the fittings are part of the pump head.A pump is a machine that transports liquids or pumps liquids.
- Q: What is the function of the heating pump system for the water pump design?
- As the feed water temperature is higher, in the case of non warm pump start, will make the pump body is subject to greater thermal impact; in addition, the flow components with the pump contact heating fast, not contact with water directly heating slowly. This expansion due to uneven speed, it will inevitably produce thermal stress, deformation of the pump body, sealing surface, the joint surface is lax and leaking phenomenon. Therefore, the warm water pump system is designed for the water pump.
- Q: What should be used to pay attention to the use of mechanical pumps?
- When opening the pump, first close the outlet valve, lift the pressure, then open the outlet valve again, pay attention to the flow of the motor.
- Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
- Submersible pump cable or motor insulation is damaged.3) motor water solution