• Permanent Magnet Water Pumps System 1
Permanent Magnet Water Pumps

Permanent Magnet Water Pumps

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:

1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,

2.It's apply to Chemical liquid(acid or alkali) transportation.

3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:


1. Model :MP


2.Pump Material:F-GFRPP  A-CPVC  P-CFRPVDF  E-CFRETFE


3.Power:203-45W  204-65W  255-90W  257-150W  258-260W


4.Connection Type of inlet/outlet :S-screw type   H- Straight pipe type


5.Pump spindle:C-CERAMIC  T-TITANIUM(Ti)  S-SIC


6.Rubber Material :E-EPDM  V-VITON


7.Frequency :5-50Hz  6-60Hz

8.Voltage :V11-110V/220V/1ø  V38-220V/380V/3 ø


Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
That is impossible. The suction height of the pump is caused by the centrifugal force of the vacuum. The water is sucked into the vacuum
Q:What are the characteristics of the piston pump?
1 、 built in overvoltage protection and flow correction system.6 、 large screen LCD display.7. The well designed exhaust device can effectively remove the bubbles in the liquid.8, flow and pressure settings can be memory, and PLC communication (custom).
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:What's the pump? Where can I use it?
Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.
Q:Pump unloading in hydraulic transmission,
Unloading is pumping oil directly back to the tank, the pressure is very low, energy saving
Q:What is the minimum continuous flow of a pump?
Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
Q:Know flow and lift how to calculate the pump power?
P: the density of refrigerant, when the working fluid is water, P =1ETA - pump efficiency, can not find desirable value =0.8N=30x (200/3600) x9.81x1/0.8=20.44 = 20 (kW)(that is, 20kW motors)
Q:Fire hydrant pump button, under what circumstances do not need to install?
The installation of hydrant pump buttons depends on the type of water supply:(1) municipal water supply; (in this case, do not have to install)(2) there is a fire pump; (must be installed)
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Because the characteristic curves of the two are different.The power of centrifugal pump decreases with the decrease of flow rate. When the flow rate is zero, the power is minimum, so the centrifugal pump is started with a closed valve.
Q:What are the general water pump failure, how to repair?
Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords