Permanent Magnet pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:
1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,
2.It's apply to Chemical liquid(acid or alkali) transportation.
3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:
1. Model :MP
2.Pump Material:F-GFRPP A-CPVC P-CFRPVDF E-CFRETFE
3.Power:203-45W 204-65W 255-90W 257-150W 258-260W
4.Connection Type of inlet/outlet :S-screw type H- Straight pipe type
5.Pump spindle:C-CERAMIC T-TITANIUM(Ti) S-SIC
6.Rubber Material :E-EPDM V-VITON
7.Frequency :5-50Hz 6-60Hz
8.Voltage :V11-110V/220V/1ø V38-220V/380V/3 ø
- Q: What are the meanings of the vacuum pump, the front pump and the main pump?
- The main pump can be understood as a booster pump, used to improve the vacuum mechanical pump with pumping quantity. As the roots pump, diffusion pumps, molecular pump. These can not use (too much pressure) so the need for mechanical pump drainage, the vacuum chamber is pumped into the rough vacuum, then the main pump starts to work.
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- (1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
- Q: What are the general water pump failure, how to repair?
- Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.
- Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
- The elevator is mainly used by the power grid through the rectifier, filter, inverter and other transmission to the motor. The motor in high speed when the brake suddenly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power, the reverse voltage and torque original electric state torque instead, and the motor with brake strong torque, forcing the rotor to stop fast but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible and therefore cannot go back to the grid, energy will be accumulated in the filter capacitor, produce pump voltage, this phenomenon of pump voltage converter has great destructive power.
- Q: What is the dry running protector of screw pump? What's the principle and function? Thank you
- The utility model relates to a screw pump dry running protector, which is used for protecting the stator and the rotor of the screw pump from being transported by air
- Q: How many kinds of pumps are available and the operating principles of various pumps?
- The volume type pump, depending on the periodic change of sealing liquid containing space volume, the energy is periodically transmitted to the liquid, the liquid pressure increased to force the liquid discharge, according to the motion form of work elements can be divided into reciprocating pump and rotary pump. Other types of pumps transmit energy in other forms. As the jet pump work on high-speed jet of fluid will be required to transport fluid suction pump after mixing for momentum exchange in order to transfer energy; water hammer pump by water when braking in the flow of energy transfer is to rise to a certain height; the electromagnetic pump is energized to make the liquid metal in the electromagnetic forces generated in the flow and transport. In addition, the pump can also be classified according to the nature of the transmission fluid, driving methods, structure, use and so on.
- Q: What are the characteristics of a vertical multistage centrifugal pump?
- Vertical multistage centrifugal pump system using the latest international advanced IS type hydraulic model based design for high efficiency centrifugal pump with multi segment, the soft packing or mechanical seal, has the characteristics of high efficiency, large flow, high lift, no leakage, a wide range of performance, safe operation, stable operation and long service life and small area.
- Q: Rules for operation of centrifugal pumps
- 3, start the pump, wait until the speed reaches the normal speed, slowly open the outlet valve, observe the ammeter at the same time, and control the current in the rated current range of the motor.4, the operation requires smooth operation of water pumps, no abnormal noise, no pressure fluctuations. The abnormal situation should be stopped in time.
- Q: What's the difference between a concrete pump and a concrete pump truck?
- Concrete pump is a pumping machine used in the field, while the concrete pump truck is a truck mounted pump.
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system: