Oil-filled Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product introduction:
QYOil-filled submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller. Motor which is triphase is at the upper part of pump and seal is used where pump and motor combine, which is a kind of double end mechanical seal"0"rings are applied to all static joints.
Axial flow impeller design can meet customer demand for big flow
Application:
This series pump because of wide range of flow and head, is extensively used for electrical irrigation, forest water spraying, pumping water from well, water tower deliver and urban construction water supply and discharge for farms, villages, industrial and mining enterprise.
Work Conditions:
The pump can work properly and continuously under following operational conditions:
1.Medium is not corrosive. Sand contents should be max. 0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40°C and PH should be 6.5-8.5.
3.The pumps should be operated within rated head.
4.The pumps should be fully submerged into water with depth of less than 3m and max. The pump should be min. 0.5m over (he water bottom and not be inserted into sludge.
5.Power frequency should be 50Hz,three-phase vollage 380V.and voltage fluctuation should be 0.9-1.1 limes than the rated.
- Q: How to adjust the flow of piston pump?
- The oil pan with oil liquid through the suction port and the piston cylinder; from 180 degrees to 360 degrees, the piston cylinder volume decreases, so the oil liquid in the pan with oil discharged from the outlet of the liquid. The pump works continuously as long as the drive shaft rotates.
- Q: What are the uses and precautions of magnetic pumps?
- Notice of use:1. prevent particles from enteringHas the ferromagnetic impurities and particles into the magnetic actuator and bearing friction is not allowed.The transport of crystallization or precipitation of the medium to the flushing (after pumping water, poured into the pump cavity drained after running 1min), in order to ensure the service life of bearing.The transport medium containing solid particles, the pump flow tube inlet filter.
- Q: What are the general water pump failure, how to repair?
- (4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
- Q: What are the important parameters of the pump?
- The head is the unit weight of liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid used, referred to as meters.Speed nThe speed is the number of revolutions per unit time of the pump shaft. It is indicated by the symbol n. The unit is r/min.Cavitation allowance NPSHCavitation margin, also called net positive suction head, is the main parameter to indicate the cavitation performance. The cavitation margin has been expressed by delta H at homePower and efficiencyThe power of water pump usually refers to the input power, that is, the power transferred by the prime mover to the pump shaft, so it is also called shaft power. It is expressed by P;The effective power of the pump, also known as the output power, is expressed in Pe. It is the effective energy obtained by pumping the liquid out of the pump in unit time
- Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
- Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".
- Q: There are second cutting, third cutting, why three times?
- I used to do this job before. After the impeller is cut, the flow and lift will decrease. Sometimes, the same pump will be cut according to the needs of the impeller, so as to meet the actual needs, at this time, with the power of the motor will also be reduced
- Q: What are the characteristics of a vertical multistage centrifugal pump?
- Vertical multi-stage centrifugal pump is cast iron, the advantage is that the price is cheap, the disadvantage is bulky and power consumption.
- Q: How is the pump level of submersible sewage pump determined?
- Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
- Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
- There should be the following reasons: 1) the setting value of the trip switch is too small, and the operating current of the submersible pump exceeds its setting value, and the switch is tripped
Send your message to us