Water Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Production Introduction:
WQ blockage-free sewage submersible pump(hereinafter as pump) is untegrative motor and pump. Which is manufactured based on absorbing domestic and foreignadvanced technology and advantages. Impeller, designed with hydraulic model and made by precision casting, has the advantages of energy-saving, anti-winding and non-clogging,etc. At the same time, the pumps have a unique effect in the carriage of solid particles and long fibers garbage. Single or dual impeller structure ensures the pump has the higher efficiency when it has bigger flow. So this king of pump is a ideal drainage pumps for industries and cities.
Application:
1. Living waste water discharging
2.Sewage system of municipal works
3.Sewage system in factory and mine corporation
4.Other transportation of none orrosive and diluted medium
5.Temporary floodwater discharging
6.Waste water discharging of public facility
7.Various waterd is chharging system
Work Conditions:
1.Capacity scope:2-1500m³h;
2.System pressure:≤0.6mpa;
3.Medium consistency:≤1.3x10³kg/m³
4.Motor insulation class:IP68;
5.Rotation:clockwise rotation viewed from motor;
6.Rated Speed:970-2900r/min;
7.Head scope: 3-45;
8.Medium temperature:-15℃-+60℃;
9.Medium PH scope:5-9;
10.Motor insulation class:E Grode;
- Q: Know flow and lift how to calculate the pump power?
- N=Q.H.g. P / nN - motor power, kWH - pump head, MQ - pump flow, m^3/sG - gravity acceleration g=9.81
- Q: Working principle and diagram of axial piston pump with pressure compensation variable
- Adjust the flow characteristics, the first limit screw to the top, according to the flow and pressure changes in the required range, adjusting the spring set, the initial flow pressure began to change to meet the requirements, then the limit screw to the ultimate pressure when the flow is no longer changed, the relationship between flow and pressure the changes are determined by the pump itself.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
- Q: What does electromechanical vector pump mean?
- Commercial buildings: hotels, office buildings, department stores, large saunas, etc.Irrigation: such as parks, playgrounds, orchards, farms, etc.Manufacturing: such as manufacturing, washing equipment, food industry, factories and so on
- Q: Is the centrifugal pump large or small?
- Centrifugal pump, the smaller the better the cavitation.1, centrifugal pump cavitation less, anti cavitation performance is better, the pump cavitation is called the necessary cavitation margin or pump inlet dynamic pressure drop, the smaller the better. Generally speaking, the pump cavitation is the need for cavitation, the pump inlet pipe said effective cavitation margin, that is, the device cavitation margin. For a given pump, at a given speed and flow rate required NPSH is called pump necessary NPSH, also called NPSH, is required to achieve the performance parameters of the pump cavitation, the internal flow and the centrifugal pump is composed of pump head itself, its physical meaning is that liquid drop in pump inlet pressure part degree, is to guarantee the pump cavitation does not occur, with surplus energy exceeds the vaporization pressure head at the inlet of the pump unit weight of liquid. The cavitation must be independent of the device parameters. It is only related to the parameters of the inlet of the pump. These parameters are determined by the geometric parameters at a given speed and flow.
- Q: Why is the flow of the pump too small will occur cavitation phenomenon?
- Why is it easy to produce cavitation when the inlet flow of pump is lowered?This is because the main performance parameters such as the head, power and efficiency of the centrifugal pump are not fixed, but vary with the flow rate. The curve drawn on a coordinate paper is called the performance curve or characteristic curve of the centrifugal pump. What happens when the flow rate decreases? The disadvantage of throttling adjustment is that the pump flow is small, and the impeller is easy to cause cavitation
- Q: Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
- Unreasonable, easy to produce throttling loss, pressure loss, pressure reduction, easy to cause cavitation
- Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
- The worst case is that the pump is not automatic when it leaves the factory, and no one can say whose product is 100%.But there may be automatic control of this piece, not debugging (this depends on the specific product manual or manufacturer)
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Send your message to us
Water Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords