• NA2XSEYRGbY 3.6/6 kV-20.3/35 kV , xlpe insulated round steel wire armoured, three-core cables System 1
NA2XSEYRGbY 3.6/6 kV-20.3/35 kV , xlpe insulated round steel wire armoured, three-core cables

NA2XSEYRGbY 3.6/6 kV-20.3/35 kV , xlpe insulated round steel wire armoured, three-core cables

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
1000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:


Brand Name:


Model Number:


Insulation Material:

XLPE

Type:

Medium Voltage

Application:

Industrial

Conductor Material:

Aluminum

Jacket:

PVC



Packaging & Delivery

Packaging Detail:DRUM
Delivery Detail:4-5 WEEKS

Specifications

1-Stranded aluminium cconductor 
2-XLPE insulation 
3-Copper wire screen 
4-Galvanized round steel wire 
5-Galvanized steel tape


Q: I had a power outage and I fixed it and now my cable wont work. The cable box is on it's just that there is no picture and not even the control can make it work. Can anyone figure out a way to help me with this?
Comcast Power Outage
Q: What is the safe carrying capacity of the power cable YJV22-10KV-3 * 400?
Depending on how much of the 24 switches that U ah, 1U, then up to 42 slightly, but still empty position good heat dissipation, 2U, then installed a 20 up to the bar.
Q: Basically i want to add another ssd using a power splitter cable, however i was wondering if you could use the power splitter cable with the optical drive instead of with the current hard drive, (im asking this as there's no room to place the ssd drive close to the hard drive)Thanks
Yes it will work just fine.
Q: HiIs it advisable to run 110VAC cable from the sub stationa and 110VAC cable from generator (clean) in the same conduit ; one of them for lighting and the other for CCTV; the concern is if the one for lighting is not clean (not consisting of a pure sine wave or carrying interference) would that effect the power line of the CCTV and has an effect on the picture? even though both are 110VAC.the installation is over seas where the power from the station is not consistence.
If both are simple power lines, then you won't have a problem. The only time you need to be cautious is when you are running a high-voltage power cable and a signal cable alongside each other e.g. a 110VAC cable alongside a 4-20ma signal line from a transmitter. The reason for the potential interference is that the power cable emits an electro-magnetic field which can potentially cause induction in the cable alongside it and effect the signal with an induced EMF. The likelihood of this depends on the cable type, screening and correct earthing measures. It's a good bet to never run a power and signal cable alongside each other, and if you have no other choice, seperate them by means of a makeshift Faraday Cage. If both are doing nothing other than supplying power to the system though, then any induced EMF will be so minute, it will not likely affect the system in any way.
Q: I got two hard drives. The cable connecting the hard drive has 2 connectors, does it matter which connector goes to the master drive and which goes to the slave drive? same question regarding the power supply. 2 connectors on the power cable, the order matters?
Master HDD connects to the end of the ribbon cable. Slave drive connects to the mid-connector. It is best to connect master to the power connector closest to power supply (less wire resistance).
Q: So my computer monitor keeps flickering on and off and I'm pretty sure the cable just needs to be replaced. My concerns or questions are,-Are all power cables compatible, or do I need a specific one for my model?-If not compatible, how do I tell what type of monitor I have or what it's model is?Deeply appreciated,Lauren
Hi Lauren, Dell monitors use the same power cable as the system tower does. They are interchangeable. You may try swapping the power cables of the monitor and the tower to be sure that the cable is faulty. Hope this helps. Regards, GauravS
Q: what does it mean by 4 core cable, 35 mm. can it be used for DC and AC as well. can it be used for a 3 phase AC. what are its advantages and disadvantages? is one core means one phase? can we use 2 core cable for 3 phase AC? am really confused please explain.
A 4 core cable has 4 conductors in an overall sheath. The 35 mm indicates the area of each conductor's copper is 35 square mm. You can use the 4 core cable for 3-phase power (3 wires with a spare or ground). You cant use a 2-core cable for three phase service, unless you are using three 2-core cables with the 2 wires connected in parallel to provide one of the phases. It can be used for AC or DC. TexMav
Q: Hey guys I have a compaq sr5550f desktop the power light under the cable is flicking green but the computer will not turn on or off yesterday it was fine but unable to connect to the monitor I have saying no signal? whats up with it it was fine two days ago I unplugged all cables and let it rest and still the same result even if i unplug all the cables it still flickers green the dies off then if i plug it back it does it again help?
hi: All solutions above talking approximately battery backup are almost comparable, yet with differing terminology. the object you choose is definitely referred to as an Uninterruptible potential furnish. APC is a sturdy sort. I even have 2. to boot to protecting the laptop from potential outage, they help shelter against potential line spikes. besides the shown fact that, they do no longer often final for hours, in ordinary terms a jiffy (10 to 30, counting on load). A united statesthat keeps your laptop on for a pair of hours could value you over a $one thousand money (US). an excellent one which will artwork for a jiffy, offering you with lots of time to shutdown if the potential is off for a whilst, will run decrease than $one hundred. i've got seen them for extra or less $40. There ought to be some much extra decrease priced. a extra effective plug strip isn't the respond. you are going to be making use of a united stateswith a pc besides... Too undesirable they are no longer purely offered with them! LOL Cheers!
Q: What does the cable ZR-YJV22-4 * 16 mean?
Copper core flame retardant XLPE insulated PVC sheathed power cable, three core, 6 square
Q: One day, all of a sudden my amp stopped working. I inspected the battery terminal and noticed their was corrosion on both terminals, cleaned it off, and I inspected the fuse in my positive wire for my amp and noticed the fuse was blown, replaced it and the amp would still not power on, I reinspected the fuse again and it had already blown, I replaced it once more and it did the same thing.
Theres a short either in the power cable or in the amp internally. Make sure theres in no portion of the cable thats rubbed through. Its more than likely a short to ground, or something internal to the amp. Make sure the fuse has the proper amp rating too. good luck