• Frequency Inverter Single-phase 380V class 75KW System 1
Frequency Inverter Single-phase 380V class 75KW

Frequency Inverter Single-phase 380V class 75KW

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

Specifications

1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

 

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Q:What is the frequency converter AVR?
Automatic adjustment function: AVR voltage inverter based on voltage feedback, automatically adjust the output voltage, which is not affected by the grid voltage and load change, to protect the motor from excessive voltage caused by long-term insulation damage or high magnetic density caused by excessive heating core.
Q:What's the frequency converter for? What does it look like?
The inverter is mainly used in industrial equipment, such as power plants, water plants, water supply equipment, large pumping station, it is basically a cuboid, a digital display control panel; and in the English show types into the universal type, fan pump type, vector control, different types should be used in different working conditions, voltage grade from 220V-10 million volts.
Q:What are the modes of operation of a frequency converter?
If the inverter is still protected within a specified period of time, the running curve of the starting P should be changed, from the straight line to the S, U, or reverse, S, and U lines. When the motor load is large, a longer start stop time should be adopted, and the operation curve type should be set according to its load characteristics. 41 If the inverter is still running failure, try to increase the maximum current protection value, but can not cancel the protection, there should be at least 10% to 20% of the protection margin. 51, if the frequency converter operation failure or replacement, should be replaced by a larger power converter. 61 If the inverter drives the motor in the start-up process can not reach to the preset speed, there may be two cases:
Q:A control panel I received a photoelectric switch, through the 232 interface connected to the computer, control with a 220V power supply board, computer and inverter when the inverter after the start of the photoelectric switch either do not work or turn off the flash chaos, frequency converter or 232 line open photoelectric switch will be back to normal work. In addition, when the photoelectric switch is powered separately, if the ground wire is connected to the control board, the photoelectric switch does not work. Excuse me, is this interference from the power cord? How to solve?
A) PE inverter main circuit terminals (E, G) must be grounded, the motor can be grounded and the inverter with the common ground, but not with other equipment, must play ground pile, and the ground should take place far away from electrical equipment. At the same time, the cross-sectional area of the grounding wire of the converter shall be no less than 4mm2, and the length shall be within 20m.(b) in the ground wire of other electromechanical equipment, the protective earthing and the work earthing shall be separately provided with grounding electrodes, and finally shall be imported to the electrical position of the distribution cabinet. The shield of the control signal and the shielding of the main circuit wire shall also be separately provided with earth electrodes, and finally shall be incorporated into the electrical junction of the distribution cabinet.
Q:That is, some parameters of the inverter, such as torque, current, frequency, etc., are displayed on the Kingview software interface, but not through the PLC. The idea that the MODBUS protocol between SIEMENS and 200PLC has never been successful before, so that's the idea of the ABB. If it can be achieved,Is it necessary to write the script program on the Kingview, and what problems should I pay attention to when using the MODBUS protocol in Kingview software?The problem is a little bit more, I hope the experts teach me this rookie! Thank you
As long as there are 485 communications can be, the frequency converter manual on the MODBUS protocol, the address of each parameter, in the king view on the link can do, and I hope to adopt.
Q:Knowledge, principle and operation method of frequency converter.
Basic classification of the working principle of frequency converter:Frequency converter working principle has been, so there are so many converters in the world for Mao is not the same? If you cry in this case, I can only say sorry, yes, but they can also do the classification (please open up the brain to process OCD pattern): classification according to the working mode of the main circuit, can be divided into voltage type inverter and current source inverter; switching mode in accordance with the classification, can be divided into PAM control inverter PWM control frequency converter and high frequency PWM inverter control; in accordance with the principle of classification, can be divided into V/f control inverter, slip frequency control inverter and vector control inverter; according to use classification, can be divided into general high performance frequency converter, inverter, high frequency inverter, single-phase inverter and three-phase inverter.
Q:Application of ABB frequency converter
What is the starting current and starting torque of the motor when the inverter is in operation?Using frequency converter operation, with the acceleration of the motor, accordingly improve the frequency and voltage, the starting current is limited to 150% rated current (according to the type of machine is 125%~200%). The starting current is 6~7 times of direct starting with the mains frequency power supply, so the mechanical and electrical impact will be produced. It can start smoothly with frequency converter (longer starting time). The starting current is 1.2~1.5 times the rated current, the starting torque is 70%~120%, the rated torque; for the inverter with automatic torque enhancement, the starting torque is above 100%, and the full load can start.
Q:What are the precautions for frequency converter wiring installation?
First understand the instructions, do not take the control line wrong, power line into the wire outlet is connected, you can debug it
Q:I do mining equipment, recently I used ABB frequency converter to put into our equipment, but the problem of interference really gives me a headache! We have two pieces of equipment of SIEMENS S7-200 PLC, and is used in point to point protocol communication with each other, when the converter work PLC communication interference! There are monitoring equipment, converter work, there are a large number of snowflakes on the screen, simply do not see! Not even an internal phone! I've done well in grounding, but I still can't do it! Is there any master who can teach me a trick?
You can try using the following methods:Solution of interference caused by circuit coupling:The PLC and monitoring equipment are powered by isolated transformers.
Q:Schneider 303 4KW frequency converter F 013 trouble shooting method
If the converter is overloaded, it is recommended to check the set acceleration time and whether the load is blocked or not.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords