• China Best Selling VFD Frequency Drive 3 phase 220V 380V System 1
China Best Selling VFD Frequency Drive 3 phase 220V 380V

China Best Selling VFD Frequency Drive 3 phase 220V 380V

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate

    220V Single  Phase Variable Frequency Drive 2.2KW

 

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Q: The functions of frequency converter and UPS are similar, especially the power frequency UPS?
The inverter is actually an inverter. It is the first AC into DC. And then use the electronic element to switch DC power into AC inverter. In general. Large power SCR. And an adjustable frequency. The device can be adjusted in a certain range of frequency is used to control the motor speed. The speed can be adjusted. In a certain range. The inverter is widely used in AC motor speedThe UPS power supply is also called an uninterruptible power supply. An inverter with an adjustable frequency. Battery powered. For short time power supply of computer and other equipment in case of power failure. Prevents sudden power loss and file loss.
Q: How does the PLC process the inverter output signal?
Depends on analog or switch volume, if it is analog, you can use analog input module, if it is the amount of switching, with ordinary IO on it
Q: What's the function of this brake unit?
When the motor is fast stopping, the motor will feedback the energy to the converter, causing the DC bus voltage to rise or even damage the IGBT. Therefore, it is necessary to use the braking unit to save the part of the energy to protect the converter.Inverter braking a lot, can refer to:
Q: What is the frequency converter through function?
Frequency converter is an ideal motor stepless speed regulating device. It is mainly used in three-phase and two-phase asynchronous motors. It has the advantages of small start-up current, smooth operation and complete protection facilities. The utility model is suitable for stepless speed regulation of various equipment.
Q: What's the role of an electric car, the part of a traditional car?
Optimal energy utilization.The optimal utilization of energy is another basic requirement of electric vehicle, the control system can be as much as possible the use of energy, including the use of overheating and regenerative braking energy, make full use of limited energy. Ability feedback can implement this function. It includes two kinds of vehicle braking capability feedback and vehicle coasting ability feedback. In our state, the drive motor according to the operation of the generator, the vehicle kinetic energy into electricity, can play 3 roles: auxiliary braking; energy recovery to the power battery, thereby prolonging the vehicle mileage; in vehicle heating demand, can directly use this energy heating.
Q: If you don't plug in the PG card, do you use PLC's PID control?Plug in the PG card and the PLC PID control, which is reliable and precise?
There are several kinds of closed loop, speed closed loop, temperature / pressure / flow closed loop.Since you're talking about PG cards, then obviously you have to control speed.Generally speaking, the control precision is related to the hardware, and the PLC can also output pulses.If you are small system, simple control, it is recommended that you use PG card + encoder to save the cost, you can inverter internal PID, and control accuracy is also ok.My feeling, as if the speed control precision is high, is PG card.
Q: Can a power converter be used in a motor with small power? Will it burn the motor?
Yes, the motor will not burn, if it is a small power converter, with large power motor, frequency converter will burn point
Q: I would like to ask vector control of the frequency converter, how the motor does not turn. What parameters are set up
No PG vector control (motor with encoder), set the motor parameters self-learning, rated voltage, rated current, fundamental frequency (50, 33.3, 20 HZ motor should pay attention to what kind of), pole number, frequency speed, rated power, the maximum output frequency, etc., set the end after the rotation form self-learning (motor without load), or stop shape self-learning. Even the self-learning control model parameter to the external terminal control, analog voltage is changed to external control, can be CNC, PLC or PC to control its operation.
Q: What is the main harmonic produced by a transducer? How about the degree?
To reduce the influence of harmonics, various measures can be taken, but for the inverter, the main circuit is to install an AC reactor.The input side of the inverter generates the harmonic mechanism: for the inverter, as long as there is a rectifier circuit on the power supply side, it will produce harmonics caused by nonlinearity. Based on the three-phase bridge rectifier circuit for example, AC grid voltage for a sine wave, square wave AC input current waveform, the waveform, according to Fourier series can be decomposed into fundamental and harmonics, usually containing 6m + 1 (m=1,2) harmonics, the harmonics in power grid. A single fundamental wave, combined with several harmonic waves, is called an abnormal wave
Q: Electronic governor for single-phase motor speed control, frequency converter for three-phase motor speed regulation, what are their differences in speed control effect? How does the frequency converter adjust speed? Can you give me an example?
The electronic governor for single-phase motor, by changing the access winding resistance and capacitance to adjust the motor speed, the speed of the output power supply for power has not changed, so the speed is not a kind of energy-saving control methods, such as the electric fan like for home.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords