China Best Selling VFD Frequency Drive 3 phase 220V 380V
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate
220V Single Phase Variable Frequency Drive 2.2KW
General
CNBM frequency inverter is a high-quality, multi-function,
low-noise variable frequency drive which is designed, developed and manufactured according to international standards.
It can meet different needs of industrial conditions.
The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.
Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3
Application
Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
Plastic: extruder, hauling machine, decorating machine, etc.
Pharmacy: mixer, roaster, etc.
Woodworking: engraving machine, sander, veneer peeling lathe, etc.
Papermaking: single type papermaking machine, etc.
Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
Printing: cloth-washing machine, dye vat, etc.
Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
Fan and pump: kinds of fans, blowers and pumps
Specification
Item | Specification | |
Input | Input voltage | 220/380V±15% |
Input frequency | 47~63Hz | |
Output | Output voltage | 0~input voltage |
Output frequency | 0~600Hz | |
Peripheral interface characteristics | Programmable digital input | 4 switch input, 1 high-speed impulse input |
Programmable analog input | AI1: 0~10V input AI2: 0~10V input or 0~20mA input, | |
Programmable open collector output | 2 Output (3.7kW and above: 1 Open collector output) | |
Relay Output | 1 Output (3.7kW and above: 2 Relay output) | |
Analog output | 2 Output, one is 0~10V, another is 0~20mA or 0~10V | |
Keypad | Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer | |
Technical performance characteristics | Control mode | All digital space voltage vector SVPWM algorism |
Overload capacity | G purpose: 150% rated current 60s P purpose: 120% rated current 60s | |
Speed ratio | 1: 100 | |
Carrier frequency | 1.0~10.0kHz | |
Torque compensation | Linear, multi-point, 1.3th power, 1.7th power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10% | |
Automatic voltage adjustment | It can automatically maintain output voltage constant when grid voltage fluctuates. | |
Automatic current adjustment | When the current is over current limit, under clocking automatically limits output current. | |
Function characteristics | Frequency setting mode | Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes. |
Simple PLC, multi-step speed control | 16-step speed control | |
Special function | Traverse control, length control, time control | |
QUICK/JOG key | User-defined multi-function hot key | |
Protection function | Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load | |
Working condition | Installation site | Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight |
Application environment | -10°C~+40°C, 20~90%RH (no dew) | |
Vibration | Less than 0.5g | |
Storage temperature | -25°C~+65°C | |
Installation type | Wall-mounted type, floor cabinet type | |
Cooling mode | Air-forced cooling |
- Q: What does 0L1 stand for?
- The acceleration is generally overloaded during acceleration. Load inertia is too large, the inverter power is small, or the acceleration time is too short, and so on
- Q: What are the key points of frequency converter maintenance?
- Selection of frequency converter and installation noticeType selection of frequency converter in general should pay attention to the matters (such as input supply voltage, frequency, output power, load characteristics and so on), also requires a good match with the corresponding motor requirements during normal operation, giving full play to the advantage of energy saving at the same time, to avoid the overload operation, and try to avoid dragging equipment such as pumps the inefficient work area, to ensure the efficient and reliable operation.The installation environment of inverter must try to be clean and dust, and has good ventilation environment, ventilation conditions can be considered the side wall at the bottom of the inlet exhaust, and the inverter is installed, the top and side shall be sufficient for the minimum cooling distance, inverter inverter heat dissipation, in addition, there are certain requirements the environmental humidity, high humidity, electrical insulation to reduce the inverter itself, bar metal parts easy to corrosion, and the humidity is too low and easy to cause insulation damage, generally keep the humidity between 40%-90%.
- Q: 1, the frequency converter to the motor cable should be shielded cable? 2, whether there are specifications?
- 1, there are no special specifications, but each oneThe manual must have all the precautions required for good shielding.When the output of high frequency voltage pulse, the higher the frequency, the greater the external radiation interference. UseThe line is mostly blockedExternal interference.2, if there is no other equipment around (usually 5 meters as the boundary), then the shielded line can not be used, because there is no external interference.
- Q: How does the PLC process the inverter output signal?
- Depends on analog or switch volume, if it is analog, you can use analog input module, if it is the amount of switching, with ordinary IO on it
- Q: There is a feed and send system. Now due to the severity of the material is not the same as the two converters often change speed, the workers do not understand their own, often by, often bad now how to use the best way you can use a potentiometer or other method, control of the two frequency converter, synchronous operation. Is to adjust one, and the other also with the kind of frequency, so that you can let the workers themselves to open, and the two inverters, the same manufacturer, the same model, the same load,
- What kind of communication mode does the frequency converter support? Generally speaking, it is more accurate to communicate by means of synchronization. Expensive。The main transformer potentiometer, from the analog frequency converter, may be 1, the lag will be greater than 2, analog may have a larger error, 3, analog may be subject to interference. The cheapest。You can also use synchronous controller, analog input, the two roads as the same analog, cheaper, more reliable synchronization, may be disturbed.
- Q: Today, I was asked the question, and I also brought it to you to share the following Oh!
- Inverter inside the circuit is inverterIt is a control of communication -- direct current -- CommunicationDC alternating current is called inverter
- Q: Where is the frequency converter used?
- From the industry application: 1, chemical, petroleum, electric power, municipal, mining, cement, water treatment and other industries, the main use of 380V/690V/6-10kv inverter, these industries have a large fan pump power, the original AC operation, high energy consumption, the use of inverter speed regulation can be obtained after large energy saving, so it is the the main users of the main high power converter
- Q: The frequency converter works with sharp noises. What's the process of converting electrical energy into mechanical energy?. The mechanism of sound making. Thank you
- Frequency converter (Variable-frequency, Drive, VFD) is the application of frequency conversion technology and microelectronics technology, by changing the power supply frequency of the motor to control AC motor power control equipment.
- Q: I would like to ask, the inverter in use in the grid is very high?
- In the process of using inverter, grid voltage fluctuation requirements is not high, the general phase is to allow + 20% fluctuations, three-phase is allowed 15% fluctuations, so most of the grid voltage can be satisfied, unless it is in the countryside, or more remote areas, the voltage change will exceed the allowable value. In addition, the frequency converter on the power grid harmonics also have requirements, if the harmonic content of more than 20%, will lead to frequency converter misoperation, false alarm, more serious circumstances, will lead to inverter out of control, or damage. However, most of the current harmonics will not happen, unless a large number of individual factories use frequency converters, servo, intermediate frequency furnace, welding machine and other equipment.
- Q: If you don't plug in the PG card, do you use PLC's PID control?Plug in the PG card and the PLC PID control, which is reliable and precise?
- Using PG card of frequency converter to realize closed loop vector controlFor example, vertical motion loads, such as cranes and elevators, require closed-loop vector controlIn this case, the frequency converter must install the PG card, and the encoder signal will be connected to the PG card, using the frequency converterPID instruction.In this application, the PID function module of PLC can not realize the vector control function.
Send your message to us
China Best Selling VFD Frequency Drive 3 phase 220V 380V
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords