• Online UPS 15KVA System 1
Online UPS 15KVA

Online UPS 15KVA

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Online UPS 10-20KVA

The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.

Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.


Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.


Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.


Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.


High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.


Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1

minute in load of 125-150% . It also has the output short circuit protection capability.


MODELXPC 3110LXPC 3115LXPC 3120L
Rated Power10KVA/8KW15KVA/12KW20KVA/16KW
INPUT
Phase3W+N+G
Input Voltage(207-475)VAC
Input Frequency(46-54)Hz
Input PF>0.95
Bypass voltage(302-437)VAC
OUTPUT
Output Voltage220VAC±1%
Output Power Factor0.8
Output FrequencyNormal mode:same with utility power
Battery mode:49.9~50.1Hz
THDTHD<3% (linear load);THD<5% (non-linear load)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal : 0ms
Overload Capabilityload≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing
105±5%<load≤135±5%:60s
135%≤load≤150±5%:30s >150%:0.1s
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>92%
CommunicationLCD display+RS-232 + Intelligent slot
Restart FunctionAfter turning off due to cut off voltage of battery, UPS will restart
when voltage is in (302~437Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity0~95% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(WXDXH)248×500×616
Weight(kg)273535
Specification is subject to change without prior notice.


Q: UPS's detailed knowledge?
What is "standard type" and "long-acting" UPS? Standard UPS refers to a single UPS has built-in small capacity batteries (installed in the main chassis), after breaking the power supply time is short (only a few minutes full load). The long acting UPS is equipped with a large capacity battery, need to use another battery box installed outside the UPS mainframe, the power supply time from 0.5 hours to 8 hours, according to user needs and configuration. In other words, the standard UPS is the manufacturer has set the discharge time of the UPS; and the long-term UPS is selected by the customer's discharge time UPS.
Q: The time of power supply market now sell UPS power to the power of the computer to provide not long (desktop), I want to make a now has 2 12V batteries (all 100) is a truck with the kind of, can be converted into computer for power supply by? What are the other equipment can supply thanks how long? + computer display.
Buy a second-hand UPS, the circuit is good, of course, the battery can be changed ~ ~ ha ha!Downstairs is right, my master has tried, a very old UPS changed two big dry batteries, and together, it is not the same as ~!
Q: Why does the banking system need UPS power?
The utility model is mainly used for providing stable and uninterrupted power supply for a single computer, a computer network system or other power electronic equipment, such as an electromagnetic valve, a pressure transmitter, etc..
Q: UPS what does "uninterruptible power OEM" mean?
OEM is a package word, which is the product you want to help you process, OEM is the UPS power supply.
Q: Do not know why, the day before using a good, second days, plug in, found that the computer is not connected, UPS on the backup lights have been flashing, and has been "drip" ring. Unplug the ups plug and socket, the computer is energized. Is it UPS or something?.
UPS power alarm, power supply has not enough... With computer..... Let it plug 10 minutes, plug in the computer can boot.... remember to open the power switch UPS.... otherwise it really bad... Is the simple point that you just give it a separate charge, does not go bad the...
Q: What is UPS for?
Uninterruptible power supplies also have overload protection. When overloaded (150% load), skip to bypass and return automatically when load is normal. When a severe overload (over 200% of the rated load) occurs, the uninterruptible power supply immediately stops the inverter output and jumps to the bypass state, when the input air switch at the front may also trip. After the trouble is removed, the switch is switched on and restarted to resume operation.
Q: What are the features of the UPS uninterruptible power supply?
UPS is not only a standby power supply, but also has the functions of voltage regulation, anti-interference, lightning resistance and isolation from the power system. The UPS serves as the power source of the equipment, making the device an independent electrical system, free from external influences.
Q: UPS technical index
What is UPS?UPS is the abbreviation of Uninterruptible Power Supply, which is an important external equipment to provide continuous, stable and uninterrupted power supply.In principle, the UPS is a power electronics device incorporating digital and analog circuits, automatic control inverters, and maintenance free storage devices;Functionally, UPS can effectively purify the city power when the city power is abnormal. It can also supply power to the computer and other equipment for a certain period of time when the city power breaks suddenly, so that you can have enough time to cope with it;From the use, with the coming of information society, UPS is widely used in the information collection, transmission, processing, storage and application to each link, its importance is increased with the increasing importance of information applications.
Q: There are several ups
The characteristics of online is that the inverter has been in working condition, the switching time of the power supply is zero; the output voltage and frequency stability, UPS battery used in Hercules power quality requirements of very high, because there is no switching time delay, it is reliable; the online can improve the quality of power supply, so the price is relatively expensive.
Q: Excuse me: how long is the service life of the UPS power supply?
The host can twenty years can, but some capacitance some accessories to click, lead-acid battery design life with the environment has great relationship. Then the general battery is 7 to 8 years, but the general use of 3 to 4 years will be changed, then the general gel battery can be used 6 or 7 years life, a great relationship with your maintenance. Specific, you can go to www.gdbaykee this website to check

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords