• Online UPS 15KVA System 1
Online UPS 15KVA

Online UPS 15KVA

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Online UPS 10-20KVA

The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.

Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.


Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.


Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.


Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.


High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.


Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1

minute in load of 125-150% . It also has the output short circuit protection capability.


MODELXPC 3110LXPC 3115LXPC 3120L
Rated Power10KVA/8KW15KVA/12KW20KVA/16KW
INPUT
Phase3W+N+G
Input Voltage(207-475)VAC
Input Frequency(46-54)Hz
Input PF>0.95
Bypass voltage(302-437)VAC
OUTPUT
Output Voltage220VAC±1%
Output Power Factor0.8
Output FrequencyNormal mode:same with utility power
Battery mode:49.9~50.1Hz
THDTHD<3% (linear load);THD<5% (non-linear load)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal : 0ms
Overload Capabilityload≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing
105±5%<load≤135±5%:60s
135%≤load≤150±5%:30s >150%:0.1s
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>92%
CommunicationLCD display+RS-232 + Intelligent slot
Restart FunctionAfter turning off due to cut off voltage of battery, UPS will restart
when voltage is in (302~437Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity0~95% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(WXDXH)248×500×616
Weight(kg)273535
Specification is subject to change without prior notice.


Q: Is ups computer hardware or software?
Hardware peripherals, ups. The external power supply is connected to the ups first, and the computer takes the electricity from the ups, so that the power cut will not stop the power suddenly
Q: How many loads can the UPS UPS supply?
The smallest tens of VA, the largest to hundreds of KVA have, mainly depends on your needs
Q: Can the power supply of the ups supply the lighting continuously?
It can always supply electricity.Matters needing attention1) UPS use environment should pay attention to good ventilation, is conducive to heat dissipation, and keep the environment clean.2) do not take inductive load, such as currency counting machine, fluorescent lamp, air conditioner, etc., so as to avoid damaging the uninterrupted power supply.3) the output load of UPS is controlled at about 60%, the highest and the highest reliability.4) UPS carries too light (such as 1000VA UPS band 100VA load), may cause deep battery discharge, will reduce battery life, should be avoided as far as possible.
Q: What's the difference between UPS and UP5?
All power supplies.UPS (Uninterruptible Power System/Uninterruptible Power Supply), namely, uninterruptible power supply, the battery is (for maintenance free lead-acid batteries) connected with the host, the host through the inverter module circuit of the direct current into power system equipment.UP5 micro DC power supply is also called distributed DC power supply, or embedded DC power supply and micro DC power supply". DC power supply is maintenance free lead-acid battery, intelligent high frequency charging module (self cooling type) and the input and output feeder circuit highly integrated as a whole rarely, the output of 220V (or 110V) DC operating power supply device, directly replacing the DC or AC power system operating system. Used in power plant, substation, open and close, and the user terminal and other occasions, as an equipment (such as circuit breaker operating mechanism) and two instruments (such as computer line protection device) to provide reliable uninterrupted DC power supply, installed in the switch cabinet inside the independent space, the DC power supply system composed of fault isolation to improve the reliability of the original DC power supply.
Q: How do you calculate the UPS power capacity?
For example: Santak C6KS, 6000VA (rated power) /4200W (useful power), the host DC voltage is 240V, and if extended 8 hours, the battery capacity is configured as follows:6000*8/240=200AH, according to this result, should theoretically configure 20 (240v/12v, the DC voltage of each battery is 12V) 200AH.
Q: What is the difference between inverters and UPS?
The term "voltage regulator" is also mentioned here. The voltage regulator can maintain the unstable power supply at a fixed voltage by means of a voltage stabilizing device, which is very beneficial to the normal use of the electric appliance.In civil use, voltage regulators are widely used, such as refrigerators and air conditioners, and many users install high-power regulators on the total incoming line, which makes all electrical appliances protected. We know that, especially after the power failure is resumed, the voltage will have an overload peak and the instantaneous voltage is too high. This is the reason why most of the electrical appliances are damaged.
Q: UPS model problem
The power factor is divided into the input power factor and the output power factor. Meaning is the cosine of the angle between the voltage waveform and the current waveform. The general input power factor, the bigger the better, the 0.7 is the general design standard (motor) to 0.99 (high frequency), the output power factor of the load and decide, not the bigger the better, the general design standard is (0.7, 0.8).
Q: Do not know why, the day before using a good, second days, plug in, found that the computer is not connected, UPS on the backup lights have been flashing, and has been "drip" ring. Unplug the ups plug and socket, the computer is energized. Is it UPS or something?.
If the charge is still a day, this problem may be a few reasons, the general possibility of the first two problems.First, voltage instability, the range of change is too large.Two, UPS input socket bad contact.Three, UPS's own problems.
Q: How should the UPS uninterruptible power supply be selected?
UPS battery configuration scheme and UPS uninterrupted power supply method:The battery power supply time is mainly affected by load size, battery capacity, environmental temperature, battery discharge, cut-off voltage and other factors. According to the delay capacity, determine the required size of the battery capacity, ah AH value to represent the number of hours to calculate discharge time given ampere time.
Q: What is UPS? What's the effect?
UPS is for some more important electrical equipment to provide uninterrupted power supply equipment, specific introduction, there are many online

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords