Frequency Inverter Single-phase 200V class 0.75KW
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
- Q: Laptop power adapter bad what is the phenomenon?
- Either the power is bad or the machine on the power supply module is bad to repair service
- Q: Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
- Change 6 will only be slower, the fan is no longer role. The frequency converter has a power parameter, as long as the motor is less than or equal to this power can be.
- Q: On the notebook power adapter output current and voltage issues
- This current is the maximum current value of the adapter output, Voltage matching, of course, can be charged. It is recommended to select an adapter with an output current value that is slightly larger than the original.
- Q: Is the laptop power adapter long-haul?
- This is not good, If you need to shut down, then it is recommended that the power adapter plug from the board to pull down. Because if only pull the adapter and the computer plug so that the adapter will still have the internal current through, hear the small sound is actually the sound of the current. So it is recommended that the power adapter from the outlet on the unplugged, and the computer connected to the one do not have to pull, so that will not cause the power adapter power and convenient computer to open.
- Q: Why the number of motor poles increased, the inverter capacity will increase
- The power of the three-phase motor is equal to the root number of 3 times the line current and the line voltage of the product again good with the power factor. Can also be 3 times the phase current and phase voltage of the good product and then good to power factor. The frequency converter should match the rated current of the motor, not the power of the motor.
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- First, the inverter is no problem, I used so much to meet your needs ????? But to see if your motor can run at high speed, or whether the load is small, the power to have a general amount of redundancy. 6-pole motor synchronous speed of 1000, to meet your use to be transferred between 2000 or 1900, that is to say the frequency converter output frequency to be transferred to 90 to 100HZ. ????? Constant torque load is no problem, but the fan torque load to be a small job.
- Q: Do not the laptop directly connected to the power adapter?
- 4, but you can use the external 14 ~ 20V battery, connected to the matching power plug for the notebook power supply, the effect and the use of the same power adapter.
- Q: What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
- First of all you have to understand the difference between variable frequency motor and ordinary asynchronous motor. 1, inverter motor cooling fan is not connected with the motor spindle, is independent, the fan rotation from the motor speed, to ensure that the motor cooling.
- Q: How to learn the inverter debugging and design parameters
- Personally think it is relatively simple, and now the inverter has been more intelligent, and some simple applications, and even do not need to set the parameters.