Description of Fans and  Pump use 55KW Converter Frequency

Fans and  Pump use 55KW Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse

 

Features of Fans and  Pump use 55KW Converter Frequency

1).Adopts 16 bit microprocessor, sine wave PWM control

2).Automatic torque ascension and automatic sliding compensation function

3).Output frequency 0.1-400 Hz

4).8 period of speed setting and 7 period can be running the program

5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment

6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration

7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA

8).The built-in serial communication interface RS-485(baud rate can reach 38400)

9).Save energy running and automatic voltage stabilizing section function (AVR)

10).Adjustable V/F curve Acceleration and automatic and deceleration function

11).Simple vector control and built-in PID control, and the simple positioning function

12).Sleep/wake up function and zero velocity keep function

 

Structure of Fans and  Pump use 55KW Converter Frequency

Converter Frequency

 

Application of  Fans and  Pump use 55KW Converter Frequency

★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

★Plastic: extruder, hauling machine, decorating machine, etc.

★Pharmacy: mixer, roaster, etc.

★Woodworking: engraving machine, sander, veneer peeling lathe, etc.

★Papermaking: single type papermaking machine, etc.

★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

★Printing: cloth-washing machine, dye vat, etc.

★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

★Fan and pump: kinds of fans, blowers and pumps

Converter Frequency

 

Performance of Fans and  Pump use 55KW Converter Frequency

Item Specification
Input Rated voltage T4 series: Three phase 380v, ±15%
Frequency  S/T2 series: Three/single phase 220V, ±15%
50/60Hz  ±5%
Output Voltage T4 series: Three phase 0-380V
Frequency S/T2 series: Three phase 0~220v
0-400Hz
Overload ability 150% rated current for 30s; 180% rated current for 1s;
Dissipation Cooling type  Forced Cooling
Temperature protection  Heatsink temperature >85℃ trip protection against overheat
Fan control Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work
Control Control mode Open-loop vector control, V/F control
Performance Start torque Open-loop vector control: 0.5Hz 180%; 
VF control: 0.5Hz 150%
Speed range Open-loop vector control:1:150; 
VF control:1:100
Speed control precision Open-loop vector control: ±0.2%; 
VF control:±0.5%
Function Channel of operation command Keyboard control,terminal control,communication control
Start mode Direct start, DC injection braking before start, speed tracking before start
DC injection braking Start DC injection braking, stop DC injection braking
Dynamic braking Built-in braking unit
Frequency source choice Keyboard digital frequency setting, analog AVI setting
PID control setting, telecommunications setting
Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1%
Carrier frequency 1Khz~12Khz,
Acc/Dec time 0.1~6000.0s or 0.01~600.00s
Signal Analog input AVI:0~10V
ACI:4~20mA 
Keyboard potentiometer input: 0~10V
Analog output AFM:0~10V or 0~20mA, Select through JP1 jumper
Digital input A total of 28 kinds of function could be selected from S0 ~S5.
Digital output 1 channel open collector output(MO1-MCM)
1 channel relay output( TA-TC normally open, TB-TC normally closed;
Communication Port Communication protocol Based on RS485 hardware, support standard MODBUS protocol. 
Display Functions Four digital tube display Can monitor the operation state of frequency inverter flexibly and conveniently.
Installation                                 Humidity Less than 90%RH
condensation
Vibration Less than0.6G
Elevation 0~1000m, reduce the rated specification 10% when lift 1000m for each. 
Storage temperature -20~60℃          
Structure Defend degree IP20

Q: Can different brands of laptop power adapters be generic?
1, strictly speaking, different brands of laptop power adapter is not common. Even if the logo on the voltage and current are the same should not be mixed, will cause the power interface or motherboard failure or even damage. 2, with the same brand of different models of the power can be used temporarily, but should not be used for too long. 3, the cottage power adapter is best not to buy the use of hidden dangers, including spontaneous combustion and explosion, try to use the original power adapter.
Q: How do I protect the inverter when the three-phase two-pole motor is running?
Three-phase two-pole motor running inverter protection, should be based on the protection of tips, check the corresponding manual to deal with. When the inverter protection has a corresponding protection tips (such as over-current, over-voltage, speeding, stall ... ... etc.), the product manual will generally give the corresponding protection tips. According to these measures to check, deal with, you can solve the problem.
Q: Is the speed of the motor controlled?
Slip motor is composed of ordinary squirrel cage asynchronous motor, electromagnetic slip clutch and electrical control device composed of three parts. Asynchronous motor, the stepper motor is used as the prime mover, and when it rotates, the armature of the clutch is rotated together. The electric control device is a device that provides the excitation current of the slip clutch excitation coil. Electromagnetic slip clutch, which includes armature, magnetic pole and excitation coil three parts.
Q: The Schneider inverter reports the nlp command
Current transformers are also possible, or power supplies
Q: Can the HP laptop's power adapter be universal?
Power supply low-voltage plug to the same, the voltage to the same, the current is greater than or equal to can be used
Q: Is the laptop power adapter AC and DC?
In the power adapter has a nameplate, marked above the power, input and output voltage and current and other indicators, with particular attention to the input voltage range, if the nameplate indicates that the input voltage is AC 110V, then in China's 220V mains voltage Plug it will burn.
Q: Delta VFD-A frequency converter motor number of poles set
Variable frequency Drive, VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly rectified (AC variable DC), filter Wave, inverter (DC variable AC), the braking unit, the drive unit, the detection unit micro-processing unit and so on. The inverter is used to adjust the voltage and frequency of the output power by breaking the internal IGBT.
Q: Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q: 90KW inverter start 90KW, 4-pole motor and 6-pole motor j What is the difference? The inverter can be used for it?
Three-phase AC induction motor, 4-pole speed is generally 1480 rpm, 6-pole speed was 980 rpm
Q: The emitter E of the inverter inverter module and the AC output U are not directly connected together
Corresponding to a phase of the branch of the IGBT inverter module generally appear in pairs
We are a Hi-Tech enterprise establishing the networks of development, production, logistics and service extending to all over the world from Shenzhen and Dalian. Integrating the advanced technology from Europe, America, Japan and Taiwan,.We supply customers automatic and driving products with multi-functions, such as frequency inverter, servo motor and drive, soft starter, AC Choke, EMI filter, brake Units, Brake resistor etc.

1. Manufacturer Overview

Location Liaoning,China
Year Established 2001
Annual Output Value US$5 Million - US$10 Million
Main Markets North America
South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Company Certifications ISO9001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port DALIAN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b) Factory Information
Factory Size: 5,000-10,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords