High Voltage 6KV Frequency Inverter is designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.

 

The series are compatible with all types of three-phase medium voltage asynchronous motors.

 

Application Filed of High Voltage 6KV Frequency Inverter

 

High Voltage 6KV Frequency Invertercan usually be applied in these fields:

 

Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .

 

Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill

 

Cement:  fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.

 

Oil & Gas: water injection pump, oil transfer pumps, air compressor.

 

Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.

 

Water: water supply pump, circulating pump.

 

Technology Data of High Voltage 6KV Frequency Inverter

6KV series VFD

Model

A06/050

 

 

A06/050~

 

A06/080

 

 

A06/080~

 

A06/100

 

 

A06/100~

 

A06/170

 

 

A06/170~

 

A06/220

 

 

A06/220~

 

A06/400

 

A06/400~

 

A06/610

 

Capacity(kVA)

≤500

500~800

800~1000

1000~1750

1750~2250

2250~4000

4000~6250

Rated output current (A)

≤50

50~80

80~100

100~170

170~220

220~400

400~610

Motor power (kW)

≤400

400~630

630~800

800~1400

1400~1800

1800~3250

3250~5000

Input frequency

45Hz~55Hz

Rated input voltage

6000V±10%

Power factor

0.95(>20%load)

Efficiency

0.96with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital input/output

expanded according to requirement

Ambience temperature

0~40℃

Storage/transport temperature

-40~70℃

Cooling

air cooling

Ambience humidity

<90%,without condensation

Altitude

<1000m

IP class

IP20

Size(mm)(W×H×D)

3600×2480×1200

3900×2480×1200

4200×2480×1200

 

5100×2480×1200

 

5200×2580×1200

6600×2580×1300

 

8700×2780×1400

 

Weight (kg)

3500~4000

4000~5000

5000~6000

6000~8000

8000~14000

 

 

10KV series VFD

Model

A10/080

A10/080~

 

A10/150

 

A10/150~

 

A10/210

 

A10/210~

 

A10/400

 

Capacity(kVA)

≤1250

1250~2500

2500~3500

3500~6250

Rated output current (A)

≤80Rated output current (A)

80~150

150~210

210~400

Motor power(kW)

≤1000

1000~2000

2000~2800

2800~5000

Input frequency

45Hz~55Hz

Rated input voltage

10000V±10%

Power factor

0.95(>20%load)

Efficiency

0.96with rated load

Output frequency

0.5Hz~120Hz

Frequency resolution

0.01Hz

Overload capacity

120% 1 min, 150% immediately

Analogue input

0~10V/4~20mA

Analogue output

0~10V/4~20mA

Acceleration/deceleration time

0.1~3000s

Digital input/output

expanded according to requirement

Ambience temperature

0~40℃

Storage/transport temperature

-40~70℃

Cooling

air cooling

Ambience humidity

<90%,without condensation

Altitude

 <1000m

IP class

IP20

Size(mm)(W×H×D)

4500×2480×1200

5700×2480×1200

6800×2580×1300

10600×2580×1300

Weight(kg)

3500~6000

6000~8000

8000~15000

15000~19000

 

System Principle of High Voltage 6KV Frequency Inverter

High Voltage 6KV Frequency Inverter&#13;&#10;

Q: 380V motor addition to the inverter, but also how to change its speed?
Use the star connection to reduce the speed by changing the torque
Q: Laptop power adapter current is not the same alternative?
so the output voltage, the same output polarity, the output current of the adapter can be used in smaller power notebook, and small power adapter can not be used to give Powerful notebooks,
Q: Three-phase asynchronous AC motor speed control method
First, variable pole alignment speed method This method is to change the way to change the stator winding red way to change the cage motor stator pole to achieve the purpose of speed, the characteristics are as follows: With a hard mechanical properties, good stability; No slip loss, high efficiency; Wiring is simple, easy to control, low prices; A level of speed, large difference, can not get smooth speed; Can be used with the regulator speed, electromagnetic slip clutch used to obtain a more efficient smooth speed control characteristics. This method is suitable for production machinery that does not need stepless speed regulation, such as metal cutting machine tools, lifts, lifting equipment, fans, pumps and so on.
Q: Laptop power adapter (no power supply, but indicator light)
Notebook power adapter can not charge, but the indicator light does not light the common reasons are: 1, the power adapter is broken or the connector is broken. 2, the power adapter output problem, no output or output is too low, can not give the computer charge. 3, the notebook charging interface is broken, not into the electricity charge. 4, the notebook power management circuit out of the fault, resulting in can not charge.
Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
This should be the meaning of the drive block, that is, the drive signal is locked, there is no drive signal, and start a frequency change but no voltage output, you find someone to repair the circuit board can be used normally, this is generally the circuit board Problem, the module is less likely to be bad
Q: Fuji inverter motor set the number of poles will not have any effect?
The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
Q: Do not the laptop directly connected to the power adapter?
4, but you can use the external 14 ~ 20V battery, connected to the matching power plug for the notebook power supply, the effect and the use of the same power adapter.
Q: Does the inverter set the number of poles to match the number of poles of the motor?
Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
Q: How to make the motor speed (control speed), can not use frequency
In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.
Q: 380V 2 pole motor can use the inverter?
Of course, the stator winding can be connected with concentric While enameled wire to be better, preferably 180 degrees or 155, and even dedicated enameled wire
As the leader in the field of medium Voltage Variable Frequency Drive, we have been focusing on providing the integrated solutions of automatic control and energy-saving technology etc. for customers, and its skill levels and market impact of medium voltage VFD are in the world-leading positions. We have provided products and services across more than twenty countries in six continents around the world, taking up the first market share (China) in the past nine years.

1. Manufacturer Overview

Location Beijing,China
Year Established 1998
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port TIANJIN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords