Variable Frequency Drive 6KV 1250KW VFD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Introduction :
A high tech product with our own intellectual property rights and good performance, for the speed control of 3kv / 6kv/10kv medium voltage motor.
The advantage:
Perfect output waveform, harmonics free
High power factor, high efficiency
Motor speed control & soft start enabled
Reduce operation and maintenance cost
Easy operation
Perfect protection and auto-diagnosis for fault
Typical Application
Thermal powerindustry: induced draft fan, blower, dust collection fan, compressor, sewage pump, boiler feed pump etc.
Petrochemical industry: main pumps, submersible pumps, injection pumps, circulating pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, extrusion machine, etc Mining and metallurgy: slurry pump, induced draft fan, blower,, dust removal fan, descaling pump, centrifugal feed pump, etc Cement manufacturing: water pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, induced draft fan, preheat tower fan,
pressure blower fan, cooler dust cleaning fan, ball mill for raw material, kiln gas fan, cooler exhausting fan, classifier fan, the main dust collection fan, etc Water supply and wastewater treatment: main line pumps, submersible pumps, injection pumps, circulation pump, sewage pump, cleaning pump, biological processing tower pump Other industry: pulp beater, pumps, rotating machinery, wind turbines, wind tunnel, etc
Specification
Model | A03/050~ | A03/100~ | A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40°C | ||||
Storage/transport temperature | -40~70°C | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 | 4900×2480×1200 | 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
- Q:The laptop power adapter is hot
- Notebook power adapter in the power after the use of hot is a normal phenomenon, do not worry, no danger, it will not explode. The length of this time does not matter, in the use of one or two hours will become very hot, but will always keep this temperature. And the notebook's power adapter shell are high temperature, will not burn. Notebook power adapter in addition to hot, you may hear the sound, the sound is not, very small. This sound is not a big problem, it is the power adapter power after the power filter sound, so plug in the plug after. Any power adapter basically has a sound. You can listen carefully, the surrounding environment is particularly quiet when you can hear. Power adapter is a transformer, inside the transformer coil in the AC will produce Zizi sound. Some power adapter use a long time will have this sound, but no big problem, you can continue to use. As long as the sound is not high outrageous do not control. Laptop power adapter hot and sound basic are considered normal, unless the temperature is too high or even damage to the shell or the sound is very obvious, this is a problem. The general does not affect the use of the adapter bad to buy a can. Notebooks have to protect the isolation circuit, do not worry about damage to the notebook.
- Q:The laptop power adapter is burned
- To be sure, the power adapter has a problem ~ ~ I suggest you if the warranty period to go after the sale of a ~ ~ If the insurance on Taobao Amoy on a ~ ~ ~
- Q:Do you need to rectify before switching?
- There are two ways to convert frequency, that is, cross and cross the intersection, the latter need a direct current, need no rectification, depending on your DC situation.
- Q:Why G120 inverter to be equipped with 4-pole motor?
- On the upstairs that the motor parameters to be set on the possible, such as voltage, current, power, power factor, rated efficiency, rated frequency, rated speed, motor overload factor
- Q:The relationship between the power supply of the notebook and the battery
- 2, when the laptop turns on the power adapter, and the battery power is low, the charging circuit detects the battery power is lower than the set value, the power adapter will side of the host power supply, while the battery charge. After the charge is restored, it is restored to the power supply state directly from the adapter. Therefore, the relationship between the power supply of the notebook and the battery is that the battery is charged by the power adapter when the battery level is below the set value.
- Q:Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
- 1,2P refers to the number of motor poles, so it is certainly even 2, if the inverter is set to determine the number of motor poles, please write 2P value, if 2P = 4, please write 4 3, look at the nameplate on the motor rated speed for how much, you can confirm the number of motor poles. (N = 60f / p) P: pole pairs
- Q:Is the motor having a variable frequency motor and a variable voltage motor?
- Motor with DC and AC motor, variable frequency motor and fixed frequency motor, string motor, that is, I have not heard of a transformer motor.
- Q:What is the laptop power adapter? Is it the battery?
- Notebook power adapter, of course, is not referring to the laptop battery.
- Q:Inverter 0.2KW, the motor speed requirements down to 4 turn, the motor pole 4 pole. Can the drive drive the motor?
- Can, but this is a test product, the application does not try!
- Q:Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
- It should be the inverter problem, I have encountered before, followed by the inverter upgrade was resolved. Is to replace a set of power board, power board, CPU board.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Variable Frequency Drive 6KV 1250KW VFD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches