Introduction :
A high tech product with our own intellectual property rights and good performance, for the speed control of 3kv / 6kv/10kv medium voltage motor.
The advantage:
Perfect output waveform, harmonics free
High power factor, high efficiency
Motor speed control & soft start enabled
Reduce operation and maintenance cost
Easy operation
Perfect protection and auto-diagnosis for fault
Typical Application
Thermal powerindustry: induced draft fan, blower, dust collection fan, compressor, sewage pump, boiler feed pump etc.
Petrochemical industry: main pumps, submersible pumps, injection pumps, circulating pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, extrusion machine, etc Mining and metallurgy: slurry pump, induced draft fan, blower,, dust removal fan, descaling pump, centrifugal feed pump, etc Cement manufacturing: water pump, boiler feed pump, halogen water pump, fan, descaling pump, mixer, gas compressors, induced draft fan, preheat tower fan,
pressure blower fan, cooler dust cleaning fan, ball mill for raw material, kiln gas fan, cooler exhausting fan, classifier fan, the main dust collection fan, etc Water supply and wastewater treatment: main line pumps, submersible pumps, injection pumps, circulation pump, sewage pump, cleaning pump, biological processing tower pump Other industry: pulp beater, pumps, rotating machinery, wind turbines, wind tunnel, etc
Specification
Model | A03/050~ | A03/100~ | A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40°C | ||||
Storage/transport temperature | -40~70°C | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 | 4900×2480×1200 | 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
- Q: The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
- Can be used, but is being used in the motor replacement, you need to change the frequency conversion.
- Q: Is the laptop power adapter high temperature normal? Is there anything else?
- Normal, my power adapter is also very hot, generally ignore
- Q: What is the number of parameters of the motor frequency of the Siemens inverter?
- It is best to provide the model of the inverter Oh!
- Q: How does the spindle drive system of the inverter realize the positive and negative control of the main pole?
- The general inverter has an external terminal control and communication control two modes optional, select one of them can be completed ah
- Q: I have a 11KW-4 pole inverter, now with the 4KW-4 pole motor, what impact?
- 11KW the following can be brought, the inverter rectifier module may be broken,
- Q: Does the teacher know the working principle of the inverter?
- At present the main inverter is Mitsubishi you can go to their domestic sales site to find a specific inverter manual has a detailed explanation Also popular said that the inverter is to change the operating frequency of some mechanical equipment control devices, such as motors, pumps, etc.
- Q: A water supply project, how to choose electrodes and frequency converters, such as giving a 7-storey water supply
- 1. Select the pressure pump head: 7 * 2.5 (3) = 17.5 (21) meters; this is the number of theory, in fact, should be selected 40 meters, (0.4Mpa).
- Q: Laptop power adapter problem
- First, that is called the transformer, not called the charger, not with you bite the word, but you according to the charger to Taobao search, basically one hundred percent are not found.
- Q: Inverter 0.2KW, the motor speed requirements down to 4 turn, the motor pole 4 pole. Can the drive drive the motor?
- Can, but this is a test product, the application does not try!
- Q: Speed of 3000 r / min three-phase motor how to change its speed
- Only the frequency converter to achieve the purpose of speed, because the rated voltage and frequency, the three-phase motor speed is determined by the motor within the pole pairs of pole number, but the frequency down, the speed decreases, plus a frequency converter, Can achieve the purpose of stepless speed regulation. The speed is calculated as: speed = (50 Hz * 60 seconds) / (number of poles / 2), the result is synchronous speed, the general asynchronous motor slightly lower than the synchronous speed. There is a change for the electromagnetic speed of the motor, but also to achieve the purpose of stepless speed regulation. If you have a fixed number of revolutions, you can consider buying a reducer and motor integrated, such as cycloid reducer, can also be installed between the motor and equipment reducer to achieve the purpose of deceleration.