Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q:The emitter E of the inverter inverter module and the AC output U are not directly connected together
Pairs of modules are connected in a phase branch The phase output is derived from the neutral point between the modules
Q:Laptop adapter heat
In fact, as long as the power adapter temperature is within the design range, that is, the temperature in the normal range, the general is not dangerous! So why is the power supply hot? What kind of temperature range is the normal range? Switching power supply conversion efficiency can only reach 75% -85% or so. The answer is here. Switching power supply conversion efficiency is high enough, it is still difficult to find a better way to convert. Switching power supply in the voltage conversion, a part of the energy loss, in addition to a small part of the loss in the form of waves, the majority of the way out of the heat. Switching power supply power is missing, the loss of energy is also missing, the power of the heat is also large. This is why the desktop power supply to add a fan for cooling reasons. We may wish to count, a 100W switching power supply, in the use of how much energy loss in the above!
Q:Do not the laptop directly connected to the power adapter?
3, the notebook internal circuit using low-voltage direct current work, if the direct use of 220V AC and its connection will burn the circuit in the low-voltage devices, which is absolutely prohibited, but also basic common sense. At the same time, its external power jack is also dedicated, and the AC outlet is different;
Q:Octopus AC Servo motor can be driven with ordinary inverter?
First look at AC Servo motor motor type, synchronous motor or asynchronous motor;
Q:Lenovo laptop power adapter side of the feet which is positive
Lenovo laptop power adapter side of the mouth there are clear signs positive and negative, N on behalf of the positive, L on behalf of the negative, it is recommended to carefully look at that you can know.
Q:A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
Q:Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
The belt rotation is calculated by the speed ratio. The current transferred to the motor by the inverter is approximately equal to the rated current of the motor, ie the motor's power is maximized.
Q:Yaskawa inverter reported base blockade what is the reason?
This is the base block command, when the external input block command signal, the inverter will appear this code, the code appears, the motor will be free to rotate, does not affect the use.
Q:Who knows how the frequency converter works
Rectifier circuit The function of the rectifier circuit is to convert the AC power into a DC power supply. Rectifier circuit is generally a separate rectifier module.
Q:HP laptop power adapter how to open
That thing is not generally no screws, is sticky together. If you want to split, can only use the blade along the seam a little bit of open

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords