Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q: The parameters of the inverter is 4, 6 motor can be used
Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment.
Q: The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
Can be used, but is being used in the motor replacement, you need to change the frequency conversion.
Q: How does the laptop's power adapter open
Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled.
Q: How can a variable speed multi - speed three - phase asynchronous motor be controlled by a frequency converter?
With the inverter control, then you do not need multi-speed motor, because the inverter can directly control the motor speed, if the two together, the formation of a waste.
Q: 5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
Can not be exceeded Although the inverter can run out of the motor rated speed as the motor will soon burn You want your running speed of 2m / s you have to run 5m / s so go eggs do not pull the
Q: How to disassemble the notebook power adapter
. 2, the power adapter on the side of the lateral side of the white paper, with an electric knife blade along the power adapter under the cover between the gap cut, and then hit the electric knife knife with a hammer, so that the electric knife from the adapter between the upper and lower cover cut into. In the different positions of the gap between the upper and lower covers of the adapter, use the tip of the electric knife to be scratched along the gap. When the upper and lower covers are first split, the depth of the tool is deep and then the upper and lower covers of the adapter are separated
Q: There is no inverter comes with simple PLC programming function
Inverters are generally digital input, and analog input, a digital output, etc., can also be controlled by means of communication. Digital input can be used as a positive and negative and reset the alarm, the analog input can be given as a speed, and how to use the inverter to see the specific model. Take the Siemens inverter, MicroMaster420,567 terminal 3 digital input, 8 for the 24V, 9 for the 0V, you can usually open the point on the 8th 24V back to 567, as a digital input, you can also directly into the switching power supply Of the 24V, but the switch power supply 0V and 9 terminals connected to the potential, or the inverter may not be able to identify the outside world 24V. (DP communication, USS communication, etc.), with the terminal input on the P0700 = 1, the user can set the command source, the panel can be input, 2, P0701 to P0703 corresponding to the three digital functions: parameters set to 1 forward, 2 for the reverse ... ... a lot of features and control methods, see the corresponding product manual like
Q: Is the motor having a variable frequency motor and a variable voltage motor?
Motor with DC and AC motor, variable frequency motor and fixed frequency motor, string motor, that is, I have not heard of a transformer motor.
Q: On the laptop power adapter problem
Notebook power on the two specifications, one is 65W, one is 40W, 65W power supply is a discrete graphics notebook, 40W is integrated graphics notebook. Just connected to the use of power, then there is no problem. Just if you laptop battery with the light of the words, plug in the power can not be the same as with the 65W, immediately you can use the boot. Because the current is low, the charging speed is relatively slow. The other will not have any effect
Q: Speed of 3000 r / min three-phase motor how to change its speed
Speed of 3000 r / min three-phase motor speed: Variable pole speed Change the motor stator winding wiring way to change the motor pole number, which can be level to change the synchronous speed, to achieve a variable speed motor speed. This type of speed motor currently has a series of products to choose from, such as single-winding multi-speed motor. Frequency Change the asynchronous motor stator terminal input power frequency, and make it continuously adjustable to change its synchronous speed, to achieve the motor speed control method known as frequency control. The most energy efficient is the frequency conversion motor, but the need to install the inverter in the power part of the cost is too high.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords