Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q: What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
Electronic governor is for single-phase motor, by changing the access winding resistance and capacitance to adjust the motor speed, the speed of the power supply power for the output does not change, so this speed is not an energy Type of speed control methods, such as home for the use of fans and the like. Inverter speed is the original direct input three-phase asynchronous motor power first access to the inverter, in the inverter through the PWM and other electronic converter technology to rectify the frequency AC, inverter, become a frequency controllable AC In the input to the motor, in the motor running through the V / F control, output torque control, vector control and other control methods to adjust the frequency, change the loop current, to achieve energy-saving operation, especially in the light load energy efficiency is obvious, An energy-saving products that have been widely promoted and applied
Q: Can different brands of laptop power adapters be generic?
Power adapter can not use, the key to see two factors. First, the interface must first be the same interface or can not use. Second, the output current, the output current must be strictly consistent, otherwise it would be very dangerous, the laptop overload of the current is very fragile. The final output voltage I personally think can have a difference of type 5V. Because the battery on the voltage requirements up and down can have 5V floating. I have also used a high 5V adapter, has been no problem, but this is just my personal view. Strictly the same as the best. Oh, for reference only! Since you can plug in the normal use, indicating that the interface is consistent, and the output voltage and current are the same. Then I can responsibly tell you, rest assured to use it, there will be no problem.
Q: 65w adapter and 90w laptop power adapter What is the difference?
65W and 90W is mainly based on your laptop power configuration, the general integrated graphics with 65W, discrete graphics because of the need for additional power supply, so the general need 90W, of course, there are some low-power CPU, such as 25WCPU , 35W, 45W difference, these are the beginning of the manufacturer according to the notebook's power consumption count a maximum power, and then give your laptop with adapter 90W adapter can replace 65W, as long as the interface is the same, but 65W instead of 90W sometimes there may be insufficient power lead to automatic shutdown. In general, the greater the number of watts, the larger the head, because the adapter is actually a coil will be 220V into 19V, according to the power to determine the head, the larger the watt, the same 19V, then the output current will be greater
Q: How do I protect the inverter when the three-phase two-pole motor is running?
A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
Q: Acer laptop power adapter
If the computer on the trouble, it is safe on the motherboard, but not for the motherboard for another power on the line,
Q: Laptop power adapter how to detect?
After opening to see what is burned, Estimated to be insurance and the like
Q: Fuji inverter motor set the number of poles will not have any effect?
The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
Q: Can the four motors be tuned to 2900 rpm?
Will be affected, under normal circumstances overclocking is possible, but speed is not possible.
Q: Lenovo g450 laptop power adapter specifications is what?
Lenovo G450 power adapter Model: ADP-90RH B LENOVO P / N: 36001681 Input: 100-240V ~ 1.5A 50-60Hz Output: 19V $ 4.74
Q: Speed of 3000 r / min three-phase motor how to change its speed
Speed of 3000 r / min three-phase motor speed: Variable pole speed Change the motor stator winding wiring way to change the motor pole number, which can be level to change the synchronous speed, to achieve a variable speed motor speed. This type of speed motor currently has a series of products to choose from, such as single-winding multi-speed motor. Frequency Change the asynchronous motor stator terminal input power frequency, and make it continuously adjustable to change its synchronous speed, to achieve the motor speed control method known as frequency control. The most energy efficient is the frequency conversion motor, but the need to install the inverter in the power part of the cost is too high.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords