Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
- Electronic governor is for single-phase motor, by changing the access winding resistance and capacitance to adjust the motor speed, the speed of the power supply power for the output does not change, so this speed is not an energy Type of speed control methods, such as home for the use of fans and the like. Inverter speed is the original direct input three-phase asynchronous motor power first access to the inverter, in the inverter through the PWM and other electronic converter technology to rectify the frequency AC, inverter, become a frequency controllable AC In the input to the motor, in the motor running through the V / F control, output torque control, vector control and other control methods to adjust the frequency, change the loop current, to achieve energy-saving operation, especially in the light load energy efficiency is obvious, An energy-saving products that have been widely promoted and applied
- Q: Can different brands of laptop power adapters be generic?
- Power adapter can not use, the key to see two factors. First, the interface must first be the same interface or can not use. Second, the output current, the output current must be strictly consistent, otherwise it would be very dangerous, the laptop overload of the current is very fragile. The final output voltage I personally think can have a difference of type 5V. Because the battery on the voltage requirements up and down can have 5V floating. I have also used a high 5V adapter, has been no problem, but this is just my personal view. Strictly the same as the best. Oh, for reference only! Since you can plug in the normal use, indicating that the interface is consistent, and the output voltage and current are the same. Then I can responsibly tell you, rest assured to use it, there will be no problem.
- Q: 65w adapter and 90w laptop power adapter What is the difference?
- 65W and 90W is mainly based on your laptop power configuration, the general integrated graphics with 65W, discrete graphics because of the need for additional power supply, so the general need 90W, of course, there are some low-power CPU, such as 25WCPU , 35W, 45W difference, these are the beginning of the manufacturer according to the notebook's power consumption count a maximum power, and then give your laptop with adapter 90W adapter can replace 65W, as long as the interface is the same, but 65W instead of 90W sometimes there may be insufficient power lead to automatic shutdown. In general, the greater the number of watts, the larger the head, because the adapter is actually a coil will be 220V into 19V, according to the power to determine the head, the larger the watt, the same 19V, then the output current will be greater
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
- Q: Acer laptop power adapter
- If the computer on the trouble, it is safe on the motherboard, but not for the motherboard for another power on the line,
- Q: Laptop power adapter how to detect?
- After opening to see what is burned, Estimated to be insurance and the like
- Q: Fuji inverter motor set the number of poles will not have any effect?
- The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
- Q: Can the four motors be tuned to 2900 rpm?
- Will be affected, under normal circumstances overclocking is possible, but speed is not possible.
- Q: Lenovo g450 laptop power adapter specifications is what?
- Lenovo G450 power adapter Model: ADP-90RH B LENOVO P / N: 36001681 Input: 100-240V ~ 1.5A 50-60Hz Output: 19V $ 4.74
- Q: Speed of 3000 r / min three-phase motor how to change its speed
- Speed of 3000 r / min three-phase motor speed: Variable pole speed Change the motor stator winding wiring way to change the motor pole number, which can be level to change the synchronous speed, to achieve a variable speed motor speed. This type of speed motor currently has a series of products to choose from, such as single-winding multi-speed motor. Frequency Change the asynchronous motor stator terminal input power frequency, and make it continuously adjustable to change its synchronous speed, to achieve the motor speed control method known as frequency control. The most energy efficient is the frequency conversion motor, but the need to install the inverter in the power part of the cost is too high.
Send your message to us
Frequency Inverter Single-phase 200V class 0.37KW
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords