Description Of 0.4KW ~800KW DSP Chip Inverter Frequency
0.4KW ~800KW DSP Chip Inverter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of 0.4KW ~800KW DSP Chip Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of 0.4KW ~800KW DSP Chip Inverter Frequency
Application Of 0.4KW ~800KW DSP Chip Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of 0.4KW ~800KW DSP Chip Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
- If it is normal V / F control, then do not need to modify too many parameters to limit the frequency limit of 50%
- Q: Can the laptop power adapter be generic?
- Not common. Different computer adapter interface is not the same, and the voltage, current is not the same. If just the same, you can use, the voltage can also be used.
- Q: Pump frequency converter instantaneous restart and restart the problem
- How the frequency converter works: The frequency converter is a power control device that transforms the power frequency power supply into another frequency by the on-off function of the power semiconductor device. We are now using the inverter is mainly used to pay - straight - cross mode (VVVF frequency conversion or vector control frequency), the first frequency AC power through the rectifier into a DC power supply, and then convert the DC power supply frequency, voltage can be controlled AC power supply to the motor. The circuit of the inverter is usually composed of four parts: rectifier, intermediate DC link, inverter and control. Rectifier part of the three-phase bridge uncontrollable rectifier, inverter part of the IGBT three-phase bridge inverter, and the output for the PWM waveform, the middle of the DC link for the filter, DC energy storage and buffer reactive power.
- Q: My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
- If the frequency converter is selected according to the motor rated current, then the motor current exceeds the rated current, the inverter will become overcurrent protection In this case, that is, when the inverter began to select the amount of time to stay the lack of the same power, inverter general type than the fan pump type current capacity of a high grade If the inverter selection is no problem, then please see whether the inverter is working temperature is too high, too high will cause the electronic components to resist the decline in current. First, check the inverter to work the ambient temperature, the second Please check the inverter fan is damaged, clean down the inverter fan channel and fan to see if there is no plug
- Q: What is the base blockade in the drive?
- Base blockade is to deal with ul or ce such a special application of security agencies means that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop circuit more harsh they will directly disconnect the power
- Q: The Schneider inverter reports the nlp command
- 1, the inverter control circuit with an external 24V power supply, the main circuit did not power 2, PO and PA between the short film can not cause this failure.
- Q: What is the difference between AC and DC frequency converters?
- Inverter air conditioner is relatively speaking in terms of ordinary air conditioning, ordinary air conditioning compression motor using AC induction motor, speed unchanged, 50HZ when the speed is about 2880r / min. The inverter air conditioner is the first 220V, 50HZ single-phase AC into three-phase inverter AC (25 ~ 118HZ, 56 ~ 160), the supply of compressors, through the frequency changes to adjust the compressor speed, so that continuous cooling capacity to adapt to air conditioning Load needs. L inverter air conditioner works: inverter air conditioner compressor by the variable frequency motor drag, the power inverter output frequency changes in the alternating current to the motor, so that the motor speed can be based on the needs of indoor cooling and continuous change, the final compressor cooling capacity To achieve continuous changes in the automatic control. In order to meet the continuous changes in the cooling capacity, the refrigeration system uses an electronic expansion valve, the pulse motor switch valve core, rapid control into the evaporator refrigerant flow. Power frequency changes from the inverter to achieve, as shown in Figure 1: 220V, 50HZ of the mains input, the frequency converter A / D AC / DC conversion, D / A inverter, the output frequency required by the three-phase alternating current, Room switching power supply principle is similar.
- Q: Whether the inverter can control the start and stop of the horizontal monopole centrifugal pump
- Inverter general control object is the AC motor, you are the AC motor, then the general inverter will be able to achieve start and stop, select a reasonable power section, a reasonable set of start and stop time can be very good drop protection motor. Can also achieve speed control function.
- Q: Variable frequency conversion frequency difference characteristics based on,
- Whether it is variable speed control, or string resistance speed, are the cost of energy consumption.
- Q: Is the number of Amps of the notebook power adapter higher than the original number of security on the computer?
- There is no power adapter is not the number of clocks that the current output of the current frequency is the number of security in the case of the maximum number of output support the specific output current is the number of security is based on the current power consumption of the computer But please note that the power adapter output voltage must be consistent with the original agreement is now generally 20V
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
0.4KW ~800KW DSP Chip Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 8000 pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords