Excellent Quality Electro Galvanized Hanger Wires
- Loading Port:
- Tianjin
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m.t
- Supply Capability:
- 10000 m.t/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Excellent Quality Electro Galvanized Hanger Wires
1. Structure of Electro Galvanized Hanger Wires Description:
Electro Galvanized Hanger Wires is made with choice mild steel, through wire drawing, wire galvanizing and other processes. Galvanized iron wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc.
Electro Galvanized Hanger Wires can be supplied in the form of coil wire, spool wire or further processed into straightened cut wire or U type wire. It is mainly used in construction, express way fencing, binding of flowers and wire mesh weaving.
2. Main Features of Electro Galvanized Hanger Wires:
• Antirust
• Shiny silvery color
• High strength
• Durable
• Versatile
• Good visual effect
3. Electro Galvanized Hanger Wires Images
4. Electro Galvanized Hanger Wires Specification
5. FAQ
We have organized several common questions for our clients,may help you sincerely:
① How about your products?
One of the most biggest manufacturer & supplier of wires and wire mesh,is a large-scale professional Electro Galvanized Hanger Wires factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world.Different kinds of wires and mesh are available according to customer’s requirements.
②How to guarantee the quality of the products?
We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;Our company has good marketing network and abundant operation experience. Galvanized Iron Wire are sold to all parts of the country, at the same time, exported to Southeast Asia,The management theory is based on sincerity, keeping forging ahead. We have accumulated a whole set of marketing experience, having already become a local leader engaged in steel products.
③How long can we receive the product after purchase?
In the purchase of Electro Galvanized Hanger Wires within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.
- Q: I found an old Karavan flatbed utility trailer and am currently converting it into a snowmobile trailer (2 place). Me and a friend riped all the wire off of the trailer and completely rewired it. No matter how we configure it, the lights aren't coordinated. If we hit the left blinker in the car, all the lights flash(like the hazards are on). Right blinker works fine. we wired it first from the diagram on the karavan site. Now once we think about it, they have us wiring the ground into the light. so we searched the web and found this layout.
- The problem is the difference in 4 to 6 wire . Go to an auto parts store and get the converter . It wires into your car between the plug and the tail-lights .After that , no problem with older trailer wiring .
- Q: How do current carrying wires produce magnetism... Explain, give sites and clarify.
- dear any wire that having a moving charges (electrons) are having a magnetic field around this wire in loop and u can know the direction of the loops by the right hand role that if we cauch the wire in our right hand as the thumb pointing to the direction of the current then the other fingers which arounding the wire is pointing to the direction of the magnetic lines
- Q: I am trying to take 4 lights in the basement that currently all have to be turned on independently and wire them all in series to a single switch. I just took the wires and put them to the switch and then to the first light. it came on but when i held the silver metal shielding piece that houses the wires, I got a tingle. I think that would mean I need to connect the third wire. The grounding one. The light did come on which I think means I had the pos and neg connected right. Where do I connect the ground wire and what caused the tingle? by ground wire I mean the third wire that is nothing but copper. I think I just put it to the case or the light or whatever looks like a good spot to get grounded. any extra knowledge or advice is a big help! In the mean time I will be searching the web for how to's.
- Why do you have a clean change with 4 terminals? It seems such as you have a three/way change w/floor rather of a single pole change? verify THIS 4 TERMINAL change until now YOU proceed. A single pole change would desire to have 3 terminals. Line, load and floor. you're saying the change container has only 2 wires. it quite is all you would be able to desire to connect a single pole change working a easy from one region in older installations. interior the change container - the white one is warm to the change and is a runner, (criminal). The black is the load cord lower back to the ceiling easy. Sounds as though the independent is already interior the ceiling junction container ,(2 white wires taped jointly and linked to the lamp). the two black wires are warm and taped jointly to the white to the change. would desire to be waiting to connect the white and black, interior the change container,to the recent change. because there is not any floor on the change - the floor terminal heavily isn't used. Disconnect the breaker or fuse for this circuit until now attempting to connect this change!
- Q: So I know that the neutral wire is the 'return wire'. But why does my textbook say that it has the potential to have the same amount of electricity as the live wire (if the wiring is faulty)? But essentially, if the wiring is not faulty it is technically safe to touch it, it has 0 volts.Could someone explain this to me?
- a million. whilst that is working regularly, Voltage could be present for the time of stay and independent twine. cutting-edge could flow from stay to independent twine. 2. whilst there's a fault, The voltage would be present interior the stay twine and since the circuit isn't closed, No cutting-edge could be flowing. 3. No that is no longer ultimate. yet at times, the earth twine could be transmitted to the sub station the place in its joined with the independent. 4. green 5. The Casing could be linked to earth. for this reason the independent is shorted with earth.
- Q: I recently bought a stereo for my truck. What is a good average gage for a ground wire? Speaker wire? Power wire? Last but not least a speaker control (remote) wire? If it helps, I am running a 760 watt pioneer amp on two 12 inch subs. Thanks
- It depends on the size of the amplifier. Recommended wire size should be no less than 10 gauge wire for power and ground. 4 or 8 Gauge power wire you need 4 or 8 gauge ground wire . Speaker wire depends on the speaker. Door speakers should use14-16 gauage speaker wire. Subwoofers should use no less than 12 Gauge speaker wire. Remote wire doesn't need to be big at all use can use 16-18 gauge wire for the installation.
- Q: pendant wiring hookup. issue: light is always on house wires: red, white, black, ground pendant wires: green, white, black (and a ground wire to the frame) I did connect red to green, white to white, black to black, ground to ground is connecting the red to green the problem causing the light to be always on? do I just disconnect the red to green to fix?
- First of all you need to determine where the switch that controls the box on the ceiling is. It sounds to me as though three conductor wire was used in the event that a ceiling fan might be installed at some future date. Turn off the breaker to that circuit first. Make sure it is off with a circuit tester. Remove the plate from the switch location and unscrew and pull out the switch. There will be a pair of wires ( white black and bare ground ) coming in to the box. This is where power is coming from. There will also be a trio of wires ( black, red and white plus bare ground. Which ever wire from the trio is attached to the switch will determine which hot wire to connect to in the ceiling box. You will attach that to the black wire from the fixture, the white to white and the green to bare ground. If there are two switches in the same box on the wall, choose the one closest to the door, determine wire color, cap the other color wire in the ceiling box with a wire nut and some electrical tape around it. Push it up in to the box first before any of the other wires. Then make the other connections, attach the pendant base to the ceiling box and you're done.
- Q: Its a 3 wire chandelier, 2 are attached like a regular electric cord and the third is separate. all are the same color. the ceiling has 2 wires. one tan/white and the other is red. I am comfortable with doing the connections but unsure what wires to connect
- One of the chandelier wires will go to the red and the other to the white wire--it does not matter which one goes to which. The third wire is likely bare (or green) and is a ground wire. Connect this wire to the ceiling box and to the third wire in the ceiling if there is one.
- Q: I would like to know how to wire my West Marine VHF Radio.Coming out the back of the radio is a red wire, a white wire, and two black wires. The white wire and one of the black wires are a thinner gauge then the other black and red wires. Any solutions out there? Thanks
- You could solder (best), or crimp connect a waterproof In Line fuse to the red wire, then connect it to a terminal Ring, and put over the red + battery post, then ground the black wire, by connecting a Terminal ring to it and put it over the NEG.- battery post. The In-Line fuse is circuit protection, OR you can by-pass this by conecting to a spare fuse on the Panel (red +), then ground the black wire to the Neg on the battery or neg - on the panel (fuse block). Direct connection to the battery is best, the other wires probably go to the Aux. Speaker which you will need as the speakers on the radio are too small to be heard over engine noise. Soldering works BEST, then coat with Liquid Lectric tape, or heat shrink tubing for a water resistant seal on the wires, and a good Marine connection. E-mail is open if further assistance is needed.
- Q: I have a 1997 saturn sc2. In the trunk of my car there was a wire dangling down from the top when i bought it. Asked seller and he didnt know. It is not the trunk light wire or has to do with any of the tailights,blinkers,brake lights. It looks like a factory wire. It has a bunch of holes in the connector.
- what color is the wire? i ask because i have a wiring diagram.
- Q: I bought this ceiling lamp, and there are 4 wires coming out of it. One white and one black (positive and negative), a bare copper wire for grounding, but there's also a yellow striped green wire. I was wondering what's the latter one for ?In my ceiling I have the black, white and bare copper wires.I'm Canadian by the way
- The yellow and green wire is another ground wire. In a house in North America most systems are AC and there is NO positive or negative conductor. The conductors are a ground/bare, white/neutral and any color is a hot wire. The green or yellow green are the exception to the color codes. I suggest you get a book on basic house wiring before you attempt anything besides basic replacement of devices.