1. Product Description
This product is suitable for linking the household electrical appliance, small electric tools, Instrument and power lighting devices with the rated voltage equal or less than 450/750V AC. The operation temperature of the wire is 90℃ for BV-90 and RV-90,BV-105 modle not more than 105℃,The other is 90℃.Installation temperature not lower than 0℃.
Standard: IEC60227 or BS, EN, AS.
2. Specification
Nominal seaction(mm2) | Specification | Insulation thickness | sheath | Resistance in 20 |
2X1 | 32/0.20 | 0.6 | 0.8 | 19.5 |
2X1.5 | 30/0.25 | 0.7 | 0.8 | 13.3 |
2X2.5 | 49/0.25 | 0.8 | 1 | 7.98 |
3X1 | 32/0.20 | 0.6 | 0.8 | 19.5 |
3X1.5 | 30/0.25 | 0.7 | 0.9 | 13.3 |
3X2.5 | 49/0.25 | 0.8 | 1.1 | 7.98 |
4X1 | 32/0.20 | 0.6 | 0.9 | 19.5 |
4X1.5 | 30/0.25 | 0.7 | 1 | 13.3 |
4X2.5 | 49/0.25 | 0.8 | 1.1 | 7.98 |
5X1 | 32/0.20 | 0.6 | 0.9 | 19.5 |
5X1.5 | 30/0.25 | 0.7 | 1.1 | 13.3 |
5X2.5 | 49/0.25 | 0.8 | 1.2 | 7.98 |
3.Characteristic
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
4.Pictures
- Q: Can I run a ground wire from and electrical motor to a bolt that is screwed into wood? Will this work? I have a hot tub and replaced the motor, the new motor has the thick copper ground wire mounted on the back so the wire I have is too short now to reach to where it was grounded before. I ran the wire from the motor to a bolt that is screwed into the wood frame of the hot tub. The old ground went from the motor to the metal brain box witch is also attached to wood so I figured my alternative fix is OK?
- Well wood will not provide grounding. If anything attach another wire to the bolt and run it to a metal grounding source. Either way you're going to need more wire. Wood is nonconductive and will not provide a path to ground unless the bolt you're talking about is contacting metal on the other side of the wood or something.
- Q: How much current can the six square copper wire be able to withstand?
- Remove the cable itself. If it is 22kV below the infrastructure project. Laying cables. As long as the cable T is connected to the tower (rod) in the exposed part of the protection tube should be installed. Under normal circumstances: are PE pipe laying cable. If there is a cable trench on the use of PE pipe. Ibid, bridge, overhead, etc. are not used PE pipe.
- Q: I have a 12V electrical device connected with a positive and negative (ground) wire. It is not live. Let's say I connect a second positive cable to the first one. When I turn on the power on the first positive cablee, the device runs fine. What happens if I then also turn on power on the second positive cable? Thanks.
- Thanks for answering my question, busterwasmycat. Yes, the power source is the same for both wires so I guess nothing happens when they're both on. Let me fill you in on my idea to see if you want offer any additional advice. I currently have a dash cam hardwired so that it only turns on with the car. This is fine for most cases, but there are times when I'd like to turn it on discretely after I've parked it. So I'm thinking of hooking it up with a second wire connected to a remote controlled relay that's always live. My concern was, what would happen if I forget to turn off the relay and then turn on the car? Lucky for me, nothing. Thanks!
- Q: I was just doing some investigating to my home's electrical setup, on curiosity. I noticed that I have a room with two electric heat panels, each rated at 2548W. They are on 12AWG wire, and a 20A breaker. I did the math, and came up with a total current draw of 21.23A. How come my breaker isn't tripping? And is this a fire hazard?
- it's marginal. But really rated at 2548 watts? usually they are rated at a more even number, as the power rating is not that exact, certainly not to 1 part in 2000. Where did you get this number? Similarly 21.23 amps is too exact for the conditions. also, your voltage could be lower than 120 volts, which lowers the current. So this is a homework problem? 20 amp breakers will trip very fast for a 100 amp oveload, and fairly fast for, say 30 amps. But for a value only 8% over the limit? they may never trip. Again, it's marginal, but OK. I'd want a better reading on the power rating of the heaters, and the voltage rating. .
- Q: I have an electrical switch that controls a recessed light. I need to move the switch, taking down the wall it is on. My questions is, why are there three wires in there? I understand that one of them is for power into the switch, 2nd one for power out to the light not sure what the third one is for? It is almost impossible for me to trace the line as it goes up into the ceiling.
- In North America a bare or green wire is a ground wire for safety. If it is a red wire then it is probably a traveler that goes to another switch to control the same light. In practice you have 2 switches that can control the same light.
- Q: I recently used some wire that is half as thick as regular wire for electrical. And i am wondering if that will work or should i get some thicker wire?
- Despite what some guys say, bigger is better. Speak to an electrician and get the correct size or go back to whatever you refer to as regular wire or a fire may be the result.
- Q: After taking off the old one, I noticed there are 3 different wires coming into the bracket. One looks like it goes to an outlet, or the breaker. One goes to the switch, and one goes in the direction of the kitchen.There is a single black that was connected to the fan, and that was it. All others were capped off. Now two blacks and a white were pigtailed with each other, while the other two white were pigtailed together. My question is: How do I install the fan?And why are these wires all over?The house was built in the 70s if it helps.
- ok - that sounds slightly unusual actually the owner (are you renting?) has duty to grant authorized and risk-free living? in case you very own, then your community council will examine, and help rectify probably unsafe wiring. positioned in simple terms, the Earth is there just to guard you from being greatly surprised if the casing of the fixture ought to alter into stay. it particularly is why the fairway/Earth oftentimes attaches to the gentle setting up, and to no longer the gentle itself. to respond to your questions: a million. you are able to set up it. it particularly is slightly risky, yet how low is the ceiling? If it particularly is way extreme and not going to be by risk touched, then no real concern. additionally if the casing is plastic, no longer metallic, you would be safer. yet i think the fan veins are metallic(?) 2. you additionally could make an earth via working an earth twine to the setting up from the different Earthed region. usually each and all of the metallic fittings interior the washing room would be Earthed - so radiators / pipes / bathtub / bathe. in case you have get right of entry to to sufficient of the ceiling areas to run that twine, you additionally could make an Earth. How elementary relies upon on the form of the ceilings and the format of the home. individually, i might in simple terms set up without an Earth. in case you install it properly, there is little risk of you desiring the 'lower back-up' of the Earth connection.
- Q: A two-color air-conditioning, a 1.5P air-conditioning, two TV sets, a water heater, a Yuba, a hood, a washing machine, a refrigerator, there are some normal use of lights and other appliances, housing area is 85 square meters (The actual use of the area is 70 square meters), I would like to ask how many holes in the wall of the single-strand copper wire, about how many meters, thank you!
- Because there is no plan to talk about the proportion of air conditioning alone to go to the total gate 2.5X2 + 1.53 Road bathroom outlet single walk 2.5X2 + 1.5 kitchen socket single walk 2.5X2 + 1.5 refrigerator single walk 2.5X2 + 1.5 all lights all the way 2.5X2 + 1.5 remaining socket 2.5X2 + 1.5 money on the 4 square X2 + 2.5 square
- Q: I am changing out my range hood and in the process I realized that my electrical wire will be about a foot short to where I need it to be. Is it ok to just get a piece of wire and extend it using wire nuts? I really dont want to run a whole wire.
- You can but put the connection in a steel electric box with a cover and nut and tape the nuts.
- Q: I never had this happen before. I had pre cooked bacon in the microwave, on a paper towel and cooked it for 135 sec. This is what I do all the time and never smelled like wires burning. It usually smelled good.
- a towel can leave that smell
Send your message to us
Electrical Wire Cable with Good Quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches