Cat5e Solid BC Conductor Lan Cable Supply
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Meters m
- Supply Capability:
- 1000000 Meters per Day m/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Specifications
1)Solid BC conductor cat5e cable
2)CE.ULcertified cat5 cable
3) High quality, factory price cable
CAT 5E Cable Assemblies
*Raw material of the conductor solid bare copper
*Conductor Dia 0.575+/-0.003mm23AWG
*2 CENTER CROSS
*3 SHEATH
*Sheath material:LSZH PVC
*Nominal Dia:6.5 +/-0.2mm
*Average thickness:0.60mm
Features:
1)Fast and Reliable Connection
2)Good toughness,long transmission meters
3)Twisted pairs with clear color for Easy Recognition
4)Ripcord for Convenience Use
5)OEM orders are acceptable
- Q:I am looking to do some electrical work and I was thinking of a way to make electrical wiring turn cold. I have a good imagination, so I am thinking I need to remove free negative electron ions from the conductive material. I dont know if this means it neads a load a ground or watever I mean I am guessing blind to electricity. My pops said dip it in liquid nitrogen but I detest this solution. Anyone have ideas? I really am at a loss concerning electrical circuitry, any ideas?
- Simple. Remove power source and you have whats known as a cold wire. That means un hooking wire from power, or removing fuse or breaker for wire.
- Q:First the facts:I think I have a short in an electrical wire in my wall somewhere.The circuit breaker held for 10-15 minute spurts and then would pop. I replaced it and it held for about a week. What does this mean?I installed cabinets and feard I had hit a wire or loosened a connection. I took off the cabinets (UGG) and checked all teh screw holes by cutting the rock. No punctured wires. I unplugged everything and it still popped. How can I find where in this line a short is taking place? I had heard about continuity tests that can determine where shorts are taking place. How do you do this?
- Disconnect the wires at the circuit panel. Use a continuity tester between the white and black wires - there should be no reading. Again between the green and black wires, also no reading. Once more between the white and green wires - there should be a reading (that's your ground). If there is any kind of reading between the black and anything else you have a short. Go to each outlet and disconnect it, eventually you will find the one where the reading drops to zero. If you using a tester with a light, it basically works the same. Any kind of glow means there is a short circuit.
- Q:Do I need to put the foam in the studs where the electrical wiring goes through? This is for Fire codes in MN
- This isn't a fire code, but an energy code. It is to prevent drafts, and is around all holes, not just wiring (like plumbing etc). Expanding polyurethane foam is usually used for that. It should say on the can that it is not harmful to the wiring and PVC pipes etc. It doesn't need any kind of fire rating. I assumed you are talking about a house. I am in Minnesota, and I know that this is an energy code thing and not a fire code thing for houses in Minnesota.
- Q:I am working with electrical currents and I have one battery and one light bulb and one wire. How do I make the light bulb light?
- touch the metal piece on the bottom of the light to + or - no battery then with the wire touch it to the other polarity and touch that to the other metal piece that is left on the light. sorry, its hard for me to make a lot of sense with this.
- Q:I have replaced phone chargers, computer parts,speakers, etc. Sprays don't help, I have tied up the wires, bagged them, put them out of her reach. I can't catch her doing it to spray her with water. I am getting angry, going broke and love my cat too much to get rid of her.
- There is a great product that is about $12. a bottle. This is acutually very cheap, for what damage pets do. This is called Bitter Apple. You can get it at pet supply stores or at the vet office. It is a liquid in a bottle. You squirt it on anything that the cat or dog is tempted to chew on. It has a taste that repels the cat or dog. They will not chew the spayed items any more. We have a dog that is 9 yrs old. When he was a pup, he chewed the legs on the wood dining table. The proof still shows today. We have a pet that chewed a little spot of carpet on the floor a while back. I did not know what to do to stop the chewing. Then I remembered this great product, Bitter Apple. I went and bought a small bottle. I sprayed it directly on the white carpet and bald spot of carpet. No more chewing!!!!! It works great.
- Q:I have an old farm house with 3 out buildings. The main house has electrical service. One out building has a circuit panel that then feeds to an out building and a barn. The out building with a circuit panel used to have separate electrical service but does not any longer. I would like to run a feeder line from the main house to the outbuilding circuit panel which would then provide power to the barn and additional out building. the distance between the two circuit panels is approximately 120'. there is a standard indoor line that runs most of the way. Can these two boxes be tied together at all? With the standard 12/2 line that is in place? What I would be running off this line is basically lights in the barn and 2-3 computers plus a space heater in the outbuilding.Any ideas?
- The 12/2 is not large enough to handle what you want to run in the remote locations. Start from the main panel and install a sub panel in there with room for 6 circuits. Feed the sub with a 50 amp circuit from the main panel and then run a new circuit to each of the out buildings. A 40 or 50 amp circuit to each will give enough power without the nuisance tripping that the 12/2 will develop. At each of the out buildings install a new 4 or 6 circuit panel. A direct burial cable is easy to install just dig more than 3 feet deep. Overhead means trees and equipment may damage the cables. For the direct burial cable run wire that is rated for 50 amps, use a 40 amp breaker to feed them. Trying to salvage the old installation is not worth the time or trouble. Contact a local qualified professional electrician to do the work. This would be much faster and then it will be done to current code specifications.
- Q:I have a live wire in my basement that is just dangling with wire nuts on the wires. It is a 3 wire cable w ground. I also have a wire I disconnected when remodeling that fed an outlet and ceiling light. This was a 2 wire with a ground. Can I use a junction box to tie the two cables together to get power back to my outlet and ceiling light? Would I just put a wire nut on the extra wire from the 3 wire cable? I'm assuming this would be the color wire that the 2 wire doesn't have.Thanks!
- We only have 120 or 240 volts in AMERICA, THAT'S 120 OR 240 Each leg carries 120 Volts What is this 110 you speak of ? If its a 240 line that breaker amp is at least 30 and you will burn your house down, if its a green wire than yes but make sure its a15 or 20 amp breaker, if 20 amp than make sure both cables are 12 Gage. Don't hook up a 20 amp breaker with 12 Gage wire tieing into a14 Gage wire or you will burn your house down.
- Q:i have a honda crv 2006 lately i buy a dvd car player and i install it, all are working fine exept for one thing, i could not connect the steering control to my dvd player and i dont know which wire is for that steering, can anyone help me pls.thank you so much
- Simple answer, it is time to pay an installer, unless you are an electrical engineer. the steering wheel control can be connected using a steering wheel controler. The company that makes this part is called PAC. The part is called a PAC SWIX. The controller comes in several versions (on OKorder). You must buy the Right Part for your DVD Player. If your dvd player is Kenwood/JVC/AlpineClarion you need SWI-JACK. If your DVD player is Pioneer or Sony you need SWI-PS, and Eclipse dvd needs SWI-ECL. If you have a non name brand generic DVD player, then you have a 50/50 chance that nothing will work. You must follow the instructions on the PAC package to locate the correct wire (every car is different), you must use 2 or more resistors that come in the package, wire them together correctly, then spend 10 minutes programing the controler. Or Pay an Installer $200.00 bucks to do the job right.
- Q:hi,i'm doing a preliminary search in buying a house in tucson, az, and have been looking at 1950s homes. none of the electrical is current/updated. does anyone know the year when codes were changed? i think it was in the 70s but i don't know exactly. this would help my first steps in searching, as i'm tired of looking at homes that have no ground or crazy wiring.
- The National Electrical Code and most local electrical codes are revised every few years. Electrical systems started using Romex and 3 prong outlets in the 60's, with additional revisions to how they were used in the 70's. GFI's or GFCI's (ground fault current interrupting) were required in the 90's. I have a couple Victorians in San Francisco with wiring that is almost a century old. Some houses still have gas light fixtures. It all works and is not unsafe if used properly. Each code change is a small incremental improvement to safety. I am fine with my 2-wire knob and tube wiring with fuses instead of circuit breakers in my Victorians and only upgrade the electrical systems for a particular room when I am remodelling the room. Obviously newer systems are nicer. Prior to WWII there was only one receptacle required to be in a room, after that one was required on each of the 4 walls. Now there has to be one within 6' of any point on a wall and within 2' on a kitchen countertop. You sound like you will want an 80's or 90's house. Lead paint is on walls painted before 1978 (in California, not sure about the date in Arizona). Asbestos was no longer an acceptable building material about the same time. ( I think asbestos and lead paint are fine to live with as long as you don't eat the paint and break the asbestos.) Hope this helps.
- Q:Car has electrical smell like when electrical wires burn or something electrical is hot. similar smell as when one of the wall plugs in my house burned up.Smell is inside car while driving. does not smell under hood. noticed it SLIGHTLY about a week ago. Then again, very noticeably yesterday.Headlight blew 2 weeks ago and other headlight blew 1 week ago, i replaced them. I had replaced these less than a year ago. For the past week the passenger window has not worked up or down and there was some clicking noises in that door.
- Wires burn typically when an electrical short circuit is createdIt can have many causes, a wire insulator chaffed by vbration, deteriorated or melted by touching something hot. You should have the car checked by a mechanic soon. This is how car fires start most of the timeyou should see to it before it gets worse This is not the kind of problem that can be solved over the internet
Guaranteeing stable and timely supply, credible quality and sincere service, our products sell well in both domestic and overseas markets. If you are interested in any of our products, or wish to place a customized order, please contact us. We will do our best to meet your needs.
1. Manufacturer Overview |
|
---|---|
Location | Guangdong,China |
Year Established | 2011 |
Annual Output Value | US$50 Million - US$100 Million |
Main Markets | 10.00% North America 10.00% South America 10.00% Eastern Europe 10.00% Southeast Asia 10.00% Domestic Market 10.00% Mid East 10.00% Eastern Asia 5.00% Western Europe 5.00% Central America 5.00% Northern Europe 5.00% Southern Europe 5.00% South Asia 5.00% Africa |
Company Certifications | ISO 9001:2008;ISO 14001:2004;CE;ROHS |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Shenzhen,Hongkong |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese, Japanese, Korean |
b)Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Cat5e Solid BC Conductor Lan Cable Supply
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Meters m
- Supply Capability:
- 1000000 Meters per Day m/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches