Carbon Spring Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 3000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Steel Grade:45#,60#,65#,70#,72A,72B
Standard:AISI, ASTM, BS, DIN, GB, JIS
Wire Gauge:0.4mm-4mm
Place of Origin:Shandong, China (Mainland)
Type:Drawn Wire
Application:Manufacturing
Alloy Or Not:Non-alloy
Special Use:Cold Heading Steel
Model Number:Carbon Spring Steel Wire
steel wire tensile strength:According to the customers' requirements.
Packaging & Delivery
Packaging Details: | Coils Packing,Spools Packing or according to the customers'requirements. |
---|---|
Delivery Detail: | According to the customers' requirements. |
Specifications
Carbon Spring Steel Wire
Type:Drawn Wire
Gauge:0.4-4.0mm
Steel Grade:45#,55#,65#,70#,72A,72B
Standard:AISI,ASTM,BS,DIN,GB,JI
Carbon Spring Steel Wire
The steel wire we produce are high quality and widely used for making spring,rope,hose, spring mattress,etc.
High carbon spring steel wire specifications:
1.Material:45#,50#,55#,60#,65#,70#,72A,72B,80#
2.Diameter:0.40mm-4.00mm
3.Standard:AISI,ASTM,BS,DIN,GB,JIS
4.Packing: Coils packing,Spools packing or according to the customers' requirements.
5.Weight:According to the customers' requirements.
6. 20"container:loading 20-25 Ton.
7.Tensile strength of steel wire performance table
Tensile strength of steel wire Steel Wire | |||||
Wire Diameter(mm) | Tensile Strength(Mpa) | Wire Diameter(mm) | Tensile Strength(Mpa) | ||
Grade B | Grade C | Grade B | Grade C | ||
0.40 | 1910-2300 | 2250-2650 | 1.40 | 1620-1910 | 1860-2210 |
0.45 | 1860-2260 | 2200-2600 | 1.60 | 1570-1860 | 1810-2160 |
0.50 | 1860-2260 | 2200-2600 | 1.80 | 1520-1810 | 1760-2110 |
0.55 | 1810-2210 | 2200-2550 | 2.00 | 1470-1760 | 1710-2010 |
0.60 | 1760-2160 | 2110-2500 | 2.20 | 1420-1710 | 1660-1960 |
0.65 | 1760-2160 | 2110-2500 | 2.80 | 1370-1670 | 1620-1910 |
0.70 | 1710-2110 | 2060-2450 | 3.00 | 1370-1670 | 1570-1860 |
0.80 | 1710-2060 | 2010-2400 | 3.20 | 1320-1620 | 1570-1810 |
0.90 | 1710-2060 | 2010-2350 | 4.00 | 1320-1620 | 1520-1760 |
1.00 | 1660-2010 | 1960-2300 |
|
|
|
1.20 | 1620-1960 | 1910-2250 |
|
|
|
- Q: I just learned how to do 3-way wiring, so that I can turn a light off from 2 different switches. My question is, how do I add another light to that mix, so that both lights come on/go off at the same time when I turn the switches on and off? (It's for a closet that has 2 lights in it that I want to come on/go off at the same time).
- You have to tie the wires that go to the light together. It is called parallel.
- Q: I had my uncle-in-law hook up my American Bass Pro 800 Watt Amp but he used cheap wiring. The wire is fairly small and he told me it doesnt matter how big the wire is. But what i wanna know is, Is the wire giving the amp enough power or does American Bass Pro Amps suck?? Help please
- your uncle obviously doesn't know what he's talking about. You can tell him I said that. If you want to get a lot of water to your garden, you use a bigger hose. If you want to get a lot of power to your amp, you use a bigger wire.
- Q: I want to connect a fan with light and pull chain only to a box that has the old wiring black and white to the new wiring black,white and green.Is this possible and how do I do it.
- Knob and tube wiring should be replaced - I don't care what the grandfather clause says in the electrical code -- safety first.
- Q: I had gotten 5 commercial solar cells from siliconsolar. But, I need to know where could I get wires to connect to the solar cells, in order to harness the cells energy.
- Your query should be sent to the solar cell dealers, it is a matter of buying and selling industrial materials
- Q: There are two switches – the left is for the fan, the right is for the light. They operate independently. I want to replace the light switch with one that has a motion sensor.There are four sets of bundled wires coming out of the back of the box. Each bundle has a white, a black, and a copper wire.Two black wires come out of each switch. The top wires go into two of the bundles in the back of the box, the bottom wires are connected with each other and with two more black wires coming out of the other two bundles coming out of the back of the box.All the white wires are twisted together with a red cap. All of the copper wires are twisted together with another red cap.My motion sensor has a red, black, green and yellow wire. The directions say the yellow wire is not used, because this is not a 3-way light. Is there a straightforward way to do this?
- Sure is!. You wire it exactly the way the instructions say to. Which is to use the 2 wires on the existing switch. The bare wire on the switch (if present) is the ground and goes to the green. Just like the instructions say. You are apparently letting all those other wires scare you. The motion sensor is nothing more than an automatic switch. It does the same thing the existing switch does, using the exact same wires. Do Not touch any of the existing splices. Look again at the instructions. Take a deep breath and have at. I've been in control cabinets with Hundreds of wires in them. I ignored all but the ones I need to work on. Other wise I would still be there trying to figure it out! (chuckle)
- Q: I'm wiring up a kenwood sub and amp. Everything is connected except for a quot;power control wirequot;. Not sure what this does or where I should connect it to. Any help?
- power control wire from were the amp or the stereo if its from the amp then it might be eighter the remote or the power but you said that its all wired up all ready so im thinking it might be the remote if so you run a wire from (power control wire) to the blue wire coming out of your stereo im not sure if we are talking about the same thing here but be more specific so our answers can be more accurate good luck
- Q: I no longer have enough 0 gauge wire would it be bad to use 0 gauge power wire to the amp and 4 gauge wire to ground the amp?
- all okorder /... or going into your audio dealer store asking for 3 to 5 ft of the 0 gauge wire for around 15 to 20 dollars at the max. you can also asking your friends for if the person has some extra wire willing to sale it for cheap, I totally would do it, and I have done that before.
- Q: If 46 m of nichrome wire is to have a resistance of 12.0 Ω at 20°C, what diameter wire should be used? in mm
- Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m resistivity Nichrome 150e-8 Ω-m 12 = (150e-8 Ω-m)(46m)/(πr?) solve for r, which would be the radius of the wire in meters. change to mm, and multiply by 2 to get diameter. .
- Q: I want two lights on two 3-way switches.1. Power from basement box into light #1 with 12-2 wire. 2. Another 12-2 wire from light #1 to light #2.3. A 12-3 wire from light #1 to switch #1.4. Another 12-3 wire from light #2 to switch #2. Will this do it?
- nevermind what I think....the guy under me knows EXACTLY what he is talking about! Do it exactly like he says. His way is better than mine was, honestly, because he has more experience. Thats why I deleted my own answer----we call that professional courtesy to seniority and its what electricians do when someone has more experience than we have speaks up. Now it doesnt matter what I think....I only have 22 years experience and someone with more experience than I has given better, sounder advice than I did. You should listen to him, not me.......or anybody else whom cannot match or exceed his experience. Or didnt you know that all Electricians are part of the same Brotherhood? This is why we always agree (or agree to be wrong). I was wrong, obviously, and my advice, second rate, compared to the advice you are about to get. So.....Pay attention! Wisdom follows!!!!
- Q: I have a 2 wire system in my garage and need to update to a 3 wire grounded plug. Can I leave my existed 2 conductor and just run a single 12 gauge insulated ground in the same conduit back to the panel/grounding rod. Or do I need to pull out the 2 wore replace with 3 wire ?
- You can just add a wire. If you have metal conduit and metal j-boxes all you have to do is connect a ground to the box. NEC 250.118 Types of Equipment Grounding Conductors. The equipment grounding conductor run with or enclosing the circuit conductors shall be one or more or a combination of the following: (1) A copper, aluminum, or copper-clad aluminum conductor. This conductor shall be solid or stranded; insulated, covered, or bare; and in the form of a wire or a busbar of any shape. (2) Rigid metal conduit. (3) Intermediate metal conduit. (4) Electrical metallic tubing... But if not in metal conduit then you can connect it to the first 5 feet of metal water pipe, the ground rod, the wire leading to the ground rod/metal water pipe, or the ground bar in the source electrical panel. NEC 250.130(C) Nongrounding Receptacle Replacement or Branch Circuit Extensions. The equipment grounding conductor of a grounding-type receptacle or a branch-circuit extension shall be permitted to be connected to any of the following: (1) Any accessible point on the grounding electrode system as described in 250.50 (2) Any accessible point on the grounding electrode conductor (3) The equipment grounding terminal bar within the enclosure where the branch circuit for the receptacle or branch circuit originates (4) For grounded systems, the grounded service conductor within the service equipment enclosure
Send your message to us
Carbon Spring Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 3000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords