• bare copper clad steel wire construction System 1
bare copper clad steel wire construction

bare copper clad steel wire construction

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
150mt m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Steel Grade:copper clad steel wire

  • Standard:AISI, ASTM, BS, DIN, GB, JIS

  • Wire Gauge:0.6-16

  • Place of Origin:Jiangsu, China (Mainland)

  • Type:Copper Clad Steel Wire

  • Application:steel wire rope

  • Alloy Or Not:Non-alloy

  • Special Use:Cold Heading Steel

  • Model Number:60#

  • Brand Name:tuoxin

  • packing length:200-2000M/reel

  • Model Number:TXDT009

Packaging & Delivery

Packaging Details:wooden reel,palstic reel,soft coil or as customer's requirtment
Delivery Detail:one month

Specifications

We can support
complete in specifications of
excellent quality steel wire ropes.
Welcome to contact me,
thanks

copper clad steel wire

surface treatment copper

Grade:A

Dia.ranges: 0.5mm ~ 10mm

Advantages:

Characteristics:felixable,mostly used

Easy installation,

enough strong and much more flexible than many types of cable.

High breaking strength,

protective performance is good

good flexibility, high temperature resistance,

erosion endurance, anti-fatigue and long serving life.

Production can be based on DIN, BS, MIL-W-834200 etc.

All wires in all strands have the same or similar core. FC is fiber core.


Our products are widely used in petroleum industry, chemical industry, textile industry, machinery, precision instrument, medical instrument, automobile, decoration, ships and other general areas. We can manufacture as per customer' specific requirements.

According to customers’ requirements,

further production can be  made it.

Fax, or email large order enquiries; We will quote our best prices.

Q: How much wire is required?
google awg wire table and find the resistivity of nichrome wire it will have wire of different diameters listed. 1/32 is .031 or 31 mils in diameter which closely approximates 20awg wire 20awg nichrome60 wire has 659 ohms per thousand feet An example if it says 10,243 ohms/1000' you will need (2.2/10,243) * 1000 feet of wire for your resistor to Neville:--- The wire doesn't know what system of units you used to calculate the answer. It works fine in English units.
Q: I found an old Karavan flatbed utility trailer and am currently converting it into a snowmobile trailer (2 place). Me and a friend riped all the wire off of the trailer and completely rewired it. No matter how we configure it, the lights aren't coordinated. If we hit the left blinker in the car, all the lights flash(like the hazards are on). Right blinker works fine. we wired it first from the diagram on the karavan site. Now once we think about it, they have us wiring the ground into the light. so we searched the web and found this layout.
well first you didnt say what type of plug your going to use, looked at your website and everything looks good there. your next step should be to check the tow vehicle, just to be sure it is wired right
Q: Consider a copper wire 1 mm in diameter providing the power needed to run an appliance drawing a 4.8 kW at 12 V. Assuming that no heat is radiated away from the wire while the current flows:A. What will the temperature of the wire be after the current has run for 1 second through the wire?B. What will the physical condition of the wire be at that time?(The wire was initially at 20 degrees C)
Battery's have their very own resistance (noted as their 'inner resistance'). the cost of the indoors resistance relies upon on the form of battery and its age. the full resistance of your circuit hence would be plenty greater effective than 0.064 ohm, so the present would be decrease than ninety 3.75A.. you will no longer get a electric marvel from 6V (although your tongue can detect it - no longer recommneded!). approximately 30mA around the guts can quit it. yet you may choose a plenty bigger voltage than 6V by way of resistance of the physique. in spite of the shown fact that there is achieveable of overheating the battery and/or the twine, which includes achieveable of hearth in some circumstances. Please do no longer attempt this with AC mains. There are severe detrimental aspects of deadly electric marvel and beginning a hearth. The kin risk-free practices equipment (fuse/circuit breaker/RCD) are meant to shrink the skill if the present is basically too severe or if there is an earth-leak - yet you are able to no longer possibility the risk-free practices of your self and others in this kind.
Q: What good would it do to change my spark plugs and wires would it be a good idea for a 86 year of a car they've never been changed before I was wondering would it help the car out thanks for the help
complicated subject. check out over bing and yahoo. that can help!
Q: In MA. What type of wiring should I use, and do I need any type of protection for the wire.
UF cable 12/2. Get a spade shovel and dig it under ground 12 if it isnt under a driveway(column 4 of table 300.5 of the NEC). The only protection you need for this wire is 12 of dirt and pipe where it comes out of the ground. You will have to use pipe on the side of your house and between the ground and light fixture with schedule 80 PVC or other rigid conduit. Remember before you dig to get a ONE CALL or diggers hotline to check for other buried cables/pipes. They can also tell you how deep the wire is if one is in the area of work.
Q: I have a 1989 Nissan 240sx. Somehow the fan caught a hold of the wiring harness and tore all the wires. any idea how much it's going to cost?
Buying a wiring harness will be prohibitive, and even transplanting one from a wrecking yard can be expensive. The harness can be repaired by splicing in pieces of wire where wire is missing and splicing together damaged pieces of wire. It is tedious but not particularly time consuming - I spliced in a section of harness after an engine fire in about 2 hours, working slowly.
Q: for christmas im getting my dad an outdoor speaker system buttheunder groung wire costs ALOT so i was wondering if regular speaker wire will work fine if i used it and burried?
Regular speaker wire will work for a short time, but the insulation is not designed to be used underground. It will deteriorate and short out. Your other option is to use conduit, but that will probably be more expensive that the underground wire. Wire for low voltage lights will work, but the gauge is fairly small, so not much power can me pushed through the wire. There is voltage present in speaker lines, about 32-40v
Q: ok so i have 3 questions.i have an oldsmobile cuttlas supreme and i have a 0 gauge power wire that is 17 feet is that long enough???? and i have 0 gauge ground that is 17 feet is that long enough....and about the speaker wire..i have 8 gauge speaker wire that is 25 feet..is this a good setup.make sure u answer all these questions please thank you..
the 17 ft of power wire is going to be fine. Just make sure you install an inline fuse by the battery. The 17ft of ground wire is a little bit too much, but you can cut that down. Make sure you ground the amp as close as possible so the voltage drop is minimal. The 8 guage speaker wire is way too high a gauge for speaker wire. You would be fine with 12, 14, or 16 gauge. The length needed depends on what speakers you plan to wire up. If its just subs then I would say thats more than enough. If you're powering components, you will need much more, probable close to 100. Overall it should be a good setup though.
Q: wiring diagram
Just okorder /
Q: During a lab experiment, a straight piece of copper wire is connected across the terminals of an AC generator and the current through the wire was measured. If the wire is removed and a part of it is tightly wound into a loop of many coils and the wire is then reconnected to the generator, will the measured current through the wire be greater, lesser, or the same as it was before the wire was coiled? Explain your answer.
Assuming the generator output voltage (RMS) remains constant the current will be less through the coil. By wrapping the wire into a coil it's resistance doesn't change but it's self inductance increases. AC in a wire produces an alternating (changing) magnetic field that is concentrated into a smaller space as a coil - so increasing it's strength and ability to link with the wire that produced it. When this changing magnetic field links (passes through) it's 'own' coils a self-induced 'back' EMF(voltage) is generated in the wire that opposes the 'forward' current from the generator (Lenz's law). If the geverator provides a pd = Vg and the back EMF = Vb, then the current in the coil is effectively being driven by a reduced pd = (Vg - Vb) .

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords