Axial Flow Submersible Electric Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description
Axial(fixed)flow submersible electric pump is made up of YQGN type submersible motor and Z(H)LB type vertical axial(fixed)flow pump.It is mainly used in the water supply and drainage of large submersible pump station.It can be installed easily,operates steadily without producing environmental noise or environmental high temperature.
Application Area
The pump can be used in agricultural irrigation,industry&mining,dock,urban construction and water-supply project,and water-supply&drainage of power plant.
Performance Range
Outlet diameter:1000~1600 mm
Capacity:6000~40000 m3/h
Head:1.9~18 m
Speed:250r/min 295r/min 365r/min 490r/min 590r/min
Motor power:60~1600kW(380V、6kV、10kV)
Structural Characteristics
Motor and pump are integrated,so there is no need to assemble motor,driving machine or other parts during assembly.
Installation area can be reduced due to the working under the water,saving 30%~40% project cost.
Noise is low,and there is no high temperature in the pump station.Underground pump station can be built according to requirements.The environmental landscape of ground shall be kept.
Double or triple mechanical seal is used on the submersible motor with F Grade insulation(Temperature resistance 155℃),protection grade IP68(IEC).As for hydraulic model,we absorb the advantages of products home and abroad,using the most advanced Non-constant Circulation,variable axial surface speed method.New hydraulic electrogenerating model is separately designed with high efficiency and energy-saving and better anti-cavitation performance.It is high reliable,and can be changed with traditional pump,which is convenient for users to choose types and to use.
It is operated easily.Remote control and automatic control can be achieved.
The submersible electric pump is used to solve the fluctuation of water,the building of pump station in lake area,etc.The long shaft and middle bearing of pump are saved which makes the machine work steadily and reliably.
- Q: Fire pump and shower pump flow head selection, high resolution.
- 2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
- Q: What are the characteristics of a pipe shield pump?
- Four, high melting point in the pump hydraulic side and the motor side with a jacket, the jacket can be steam or a certain temperature of liquid to prevent high melting liquid crystallization. The outer circulation pipe of the pump should also be insulated (heating) jacket. Five, high pressure shielding pump shell is a high pressure container, so that the pump can withstand high system pressure. In order to support the shield under internal high pressure, the stator coil itself can be used to bear the pressure. Can also be made in high temperature and high pressure under the operation of the canned pump. Six, since the suction port of the pump impeller center is much higher than that in stopping the pump, when inhaled NO liquid in the tube, the impeller and the increase of the pump chamber is filled with liquid, and then start without irrigation, the pump can work. Self-priming pumps are especially suited for extracting liquids from underground containers. In addition, according to different methods can be divided into liquid type, mud type, high pressure pipeline type, as well as for ships, nuclear power plants and absorption refrigeration devices for various types of canned pumps. Can also be divided into vertical, horizontal, online and single-stage, multi-level and other different types.
- Q: How to select metering pump head?
- In metering fluoride, we recommend the use of Viton, sealed PVC pump head. For most chlorination applications, it is better to use EPDM sealed NP (plexiglass) pump head. For hydrogen peroxide mixtures, only PTFE sealed PTFE pump head or stainless steel pump head can be used
- Q: There are second cutting, third cutting, why three times?
- So some pumps are written in the back of XXXX-125A or B, that is, the impeller nominal diameter is 125, A is through a cut, B is the 2 cutting. To reach the applicable conditions, only the calculation is not enough, but also after cutting to test to determine.
- Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
- Product featuresThe integrated structure of motor and pump adopts static seal, so that the pump is completely free of leakage;Full closed and no leakage structure, can transport toxic and harmful liquid substances;The shielded water-cooled motor and the cooling fan are removed to make the pump operate in a low noise and quiet condition. The utility model is suitable for occasions with high environmental noise requirements;
- Q: What is the pump delivery? What's the difference between years and years?
- Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
- Q: What is the liquid pump? What are their categories? What are their strengths and weaknesses?
- The air driven liquid pump adopts compressed air driving method, and has the following advantages:The pressure can be adjusted by manual pressure control valve or air control valveIt is driven by air and is especially suitable for explosion protection applicationsAble to achieve pre-set final pressureAutomatic pressure relief by pumpLong term conservation without consuming energyWhen holding pressure, medium will not overheatThe utility model has the advantages of convenient installation and low maintenance cost, and only needs to connect the gas source, the inlet pipeline and the pressure pipelineReliable operation, low maintenance cost and little noise at the time of operation
- Q: What are the constant pressure pumps?
- CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
- Q: Working principle and structure of external gear pump
- External gear pump is the most widely used gear pump, the general gear pump usually refers to the external gear pump. Its structure as shown in the diagram, there are mainly driving gear, driven gear, pump body, pump cover and safety valve and so on. The seal space of pump body, pump cover and gear is the workshop of gear pump. The wheel shafts of the two gears are respectively arranged in the bearing holes on the two pump cover, and the driving gear shaft extends out of the pump body and is driven by the motor to rotate. The external gear pump is simple in structure, light in weight, low in cost, reliable in operation and wide in application. When the gear pump works, the driving wheel rotates with the motor and drives the driven wheel to rotate
- Q: How to maintain and repair the booster pump of pipeline pump?
- Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.
Send your message to us
Axial Flow Submersible Electric Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords