Axial Flow Submersible Electric Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description
Axial(fixed)flow submersible electric pump is made up of YQGN type submersible motor and Z(H)LB type vertical axial(fixed)flow pump.It is mainly used in the water supply and drainage of large submersible pump station.It can be installed easily,operates steadily without producing environmental noise or environmental high temperature.
Application Area
The pump can be used in agricultural irrigation,industry&mining,dock,urban construction and water-supply project,and water-supply&drainage of power plant.
Performance Range
Outlet diameter:1000~1600 mm
Capacity:6000~40000 m3/h
Head:1.9~18 m
Speed:250r/min 295r/min 365r/min 490r/min 590r/min
Motor power:60~1600kW(380V、6kV、10kV)
Structural Characteristics
Motor and pump are integrated,so there is no need to assemble motor,driving machine or other parts during assembly.
Installation area can be reduced due to the working under the water,saving 30%~40% project cost.
Noise is low,and there is no high temperature in the pump station.Underground pump station can be built according to requirements.The environmental landscape of ground shall be kept.
Double or triple mechanical seal is used on the submersible motor with F Grade insulation(Temperature resistance 155℃),protection grade IP68(IEC).As for hydraulic model,we absorb the advantages of products home and abroad,using the most advanced Non-constant Circulation,variable axial surface speed method.New hydraulic electrogenerating model is separately designed with high efficiency and energy-saving and better anti-cavitation performance.It is high reliable,and can be changed with traditional pump,which is convenient for users to choose types and to use.
It is operated easily.Remote control and automatic control can be achieved.
The submersible electric pump is used to solve the fluctuation of water,the building of pump station in lake area,etc.The long shaft and middle bearing of pump are saved which makes the machine work steadily and reliably.
- Q: Double floor sewage pump circuit diagram of a small problem
- Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
- Q: Does the reservoir water heater press the booster pump (high marks)?
- The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
- Q: What's the meaning of the pump head in the water pump, please advise, thank you
- According to China Wikipedia network, the basic components of the water pump: motor, coupling, pump head (body) and chassis (horizontal).Pump is generally composed of pump body and pump head, in which the pump body refers to the spiral case, impeller, bearing, oil shell and sealing assembly, etc., the pump head refers to the impeller, bearings, oil ring and sealing rotating parts (including shaft), etc..
- Q: Rules for operation of centrifugal pumps
- 5, before you stop, you should gradually close the outlet valve, then turn off the power supply.6, with the check valve line, in ensuring the check valve intact, without closing the outlet valve, check the pump cavity, no air can be directly switched on.
- Q: What is the difference between centrifugal pump and positive displacement pump?
- The centrifugal pump is to rely on high-speed rotation of the impeller to do work on the fluid. These two types of pumps are also the most widely used.
- Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- 3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
- Q: The working principle of magnetic pump
- Magnetic pumpBy the pump magnetic pump, magnetic actuators, motors of three parts. The key components of magnetic actuator by the external magnetic rotor sleeve, inner magnetic rotor and non magnetic components. When the motor drives the outer magnetic rotor, the magnetic field can penetrate the air gap and non-magnetic material, driven by the inner magnetic rotor is connected with the impeller for synchronization the rotation, to achieve non-contact power transmission, the dynamic seal into static seal. As the shaft, the rotor is within a magnetic pump, isolated sets of completely closed to completely solve the problem of "run, run, drip, leak, remove the oil refining chemical industry flammable, explosive, toxic and harmful media through the pump seal leakage security risks, effectively ensure the health and safety of workers.
- Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
- And the pump at the start, if the valve opening pump, then the pump outlet pressure (head) is very small, so the pump flow will be great, the pump power is very large, causing the start-up current is very large. In addition, the starting current of the motor itself is also very large. These two factors add up to the possibility of overloading the motor, resulting in failure to start or even burn the motor.
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
- Q: Significance of water pump model ISO50-160
- A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids. Pump performance parameters include flow, suction, lift, shaft power, water power, efficiency and so on;
Send your message to us
Axial Flow Submersible Electric Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords