• Assembled prefabricated branch cable FZ-NHVV-4 System 1
  • Assembled prefabricated branch cable FZ-NHVV-4 System 2
  • Assembled prefabricated branch cable FZ-NHVV-4 System 3
  • Assembled prefabricated branch cable FZ-NHVV-4 System 4
Assembled prefabricated branch cable FZ-NHVV-4

Assembled prefabricated branch cable FZ-NHVV-4

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

I. Characteristics of the cables
1. Using factory prefabrication methods can substantially reduce the site construction labor intensity and shorten the construction laying time;
2. Use of cables can guarantee great length and bending property, and greatly facilitates the construction in a complex place;
3. Use of cables reduces the laying space, and cables can be installed together with gas and hydraulic gas pipelines;
4. Their reliability and reliability can be fully guaranteed, for the cables are manufactured in the factory,
5. Sub-branch parts should use high strength sealed joints, which are waterproof and have properties of moisture protection, long-term maintenance and free for repair;
6. Because the cables are directly connected with households with no need of maintenance and repair and with easy and simple construction, the cables can produce significant comprehensive economic benefits.

 

II. Usage of the cables:
1. To be used for high-rise building;
2. To be used for disaster prevention equipments;
3. To be used for tunnel lighting and disaster prevention equipments;
4. To replace copper bus bar with small or medium capacity in various places.

 

III. Standards of the cables
IEC 60502 Rated Voltage 1 ~ 30KV extruded insulated power cables and accessories (International Electrotechnical Commission standards)
GB 12706 Rated voltage 35KV and below Copper core, Aluminum core plastic insulated power cable (National Standard of the People's Republic of China)
JCS 376 branch cable (Japanese Electric Wire Industry Standard)
General Rules for JIS C2810 indoor wiring electrical connection pipes (Japanese Industrial Standard)

 

Types of the cables:
Standard main cables and branch cables are all low-voltage power cables with XLPE or PVC insulation materials (IEC, GB, JIS, BS ... ...), and PVC materials covered on the outer side. Generally, the main cable is single-core or twisted multi-core cable (cables with two to five cores), the branch cables are single-core cables, and may adopt a fire-resistant, flame retardant cables in accordance with the requirements.

 

Their structures and types are as follows:

No.

Cable Description

Type

single core

three cores twisted type

four cores twisted type

five cores twisted type

1

PVC insulated PVC sheathed branch cables

FZ-W

FZ-W-3

FZ-W-4

FZ-W-5

2

PVC insulated PVC sheathed flame-retardant branch cable

FZ-ZRVV

FZ-ZRVV-3

FZ-ZRVV-4

FZ-ZRVV-5

3

PVC insulated PVC sheathed fire-resistant branch cable

FZ-NHVV

FZ-NHVV-3

FZ-NHVV-4

FZ-NHVV-5

4

Cross-linked polyethylene insulated PVC sheathed branch cables

FZ-YJV

FZ-YJV-3

FZ-YJV-4

FZ-YJV-5

5

Cross-linked polyethylene insulated PVC sheathed flame-retardant branch cables

FZ-ZRYJV

FZ-ZRYJV-3

FZ-ZRYJV-4

FZ-ZRYJV-5

6

Cross-linked polyethylene insulated PVC sheathed fire-resistant branch cable

FZ-NHYJV

FZ-NHYJV-3

FZ-NHYJV-4

FZ-NHYJV-5

 

 

 

Q: most double power cable 2900pros need around 550W.
I would upgrade to 650 watt power supply just to be safe
Q: How to distinguish between high and low voltage power cables
The bottom edge of the bridge after bending (bottom bevel) and the width of the bridge can be the same length, but the range is controlled at 100-400mm, select the length of the two points, in the bridge side to help out on the side Two vertical lines, selected bridge bending direction as the cutting opening side; open the opening side as the bottom edge to draw the two vertical lines were used as two isosceles triangle in the sub-line, the waist triangle Edge length of the formula for the L = 2 × (bridge height × sin22
Q: i herd that 2 cables in a network (ethernet) cable just carry power. and was wondering which 2 colours or on what side the 2 are.also how much voltage they carry.was hoping to make an easy router mod to stop with the head issues.cheers.
Generally there should NEVER be power on cat5, this breaks the low voltage cable regulations of almost every country in the world. The 1 and 2 pair and the 3 and 6 pair are normally data for network. Th 4 and 5 are normally for telephone and should not really be used at the same time. Most network equipment now short circuits this pair as protection against the much higher voltage (up to 90v) of telephone lines, and continuous shorting of these lines can cause equipment damage. The 7 and 8 pair are generally unused, but are sometimes used for rf to rj45 baluns used to pass video down the line. It is possible to use all these on one cable, but makes absolute nonsense of the purpose of structured cabling.
Q: Hi all, I'm moving into a new apartment August 1, and I'm wondering how far in advance I need to call the power company, cable company, etc to set up service. I know this is probably a dumb question, but throughout college I moved into apartments where at least one of the other roommates was staying (I took over someone's lease who was moving out, but the other girls stayed so I was the only new resident). But I'm moving into a one bedroom, and I've never had to set these things up before so I just thought I'd ask what the standard time frame is. Is a month enough advance notice--should I start setting this stuff up in early July? Or sooner? Again, I know this is probably dumb but I have no experience so I wanted to ask some people who've been there and done that what the procedure is. Thanks in advance!
You only need to set up power about a week in advance. As for cable,phone,etc. they can take longer to get setup. Just call and notify them of your move in date and they'll get it scheduled.
Q: Beginner cost, do not know how the calculation of power cable works, is directly from the drawings on the amount of it?
The first is to buy a computer connected to the TV dedicated audio and video lines, length specifications are: 1.8 meters, 5 meters, 10 meters, 15 meters and 20 meters, etc., everywhere sold here do not do a detailed introduction to the first step: , S-terminal video cable connection S plug the end of the line into the video on the S terminal port, while the other end of the S-terminal line into the TV behind the S terminal port, the connection is completed (Figure 1); if you You can use the "S-AV adapter" supplied by OUR to connect the S-terminal connector to the S-terminal cable, and then insert the AV head of the other head into the AV video input after the TV Mouth, the connection is completed (Figure 2). . the audio cable connection will be the audio line of the two Lotus head were inserted into the TV after the left and right channel audio input port, while the audio cable 3.5mm audio head into the audio card audio output port, the connection is completed. If you need to use the "one sub-two audio frequency line", then its 3.5mm audio head into the audio card audio output port, speakers (headphones) and audio lines were inserted into the "one two audio frequency line" 3.5 Encyclopedia of Germany, Germany and Germany Bao Bao mother on the mouth, the connection is completed
Q: Hi, I have a router connected to the internet, but one of the computer is 80 feets away from the router and it can not get 100MBps. I have force the computer to use 10MBps. Could someone please let me know what will impact the speed of cat5 cabling?
Power cables cause interference as well as distance and twists in the wire. I assume you have a cable that you made. Did you try a pre-made cable at a shorter distance to see if the ethernet card will do 100mb at all? If it works with the premade, you might have not wired the 80' cable correctly. Make sure you have the pairs crimped correctly in the connector. Pins 1 and 2 are a pair. Pins 3 and 6 are a pair. Pins 4 and 5 and 7 and 8 are paired as well. Example: Orange/white = pin 1 Orange=pin 2 Green/white=pin 3 Green = pin 6 Blue = pin 4 Blue/White = pin 5 Brown/white = pin 7 Brown = pin 8 I hope this helps.
Q: I just need the console. No controllers, power cables, AV cables, Ethernet cables, Hard Drive, and so on.I checked Google, but the only offers I can find are OKorder and RRoD'd 360s on OKorder. Do any retail stores sell just the console? Or will I have to trust nobody will send me a broken console?
The retail units only come as a set, and you shouldn't trust any unit that doesn't come with accessories, because it's either broken, repaired, or stolen. Just get the best deal and toss or sell the leftovers. (A 360 Arcade will be just fine for your purposes, the only real difference is the accessories included in the box.)
Q: the cable for my psp wont plug all the way in anymore so i cant charge it. nothing has happened to the psp. it wasnt dropped or anything, just sat on the table. same with the power cord.anyone else have this problem and if so what did u do about it.and if your thinking about saying quot;contact sonyor anything like that...just leave. i can figure that out for myself ok.
MMMM. im not sure i think you might need to buy a new one if you try to force it in you might break something
Q: Hi. I have an iBook power cable and I was wondering if there was a way to adapt it so I can use it for my new MacBook Pro that uses a magnetic cable? Thanks!
daily. It took it gradual to comprehend what became into occurring. The Holy Spirit became into guiding me yet i became into no longer following alongside very nicely. yet as quickly as you agree for him totally and thoroughly and renounce your self, then you definitely grow to be an entire new individual and hear and comprehend whats occurring. Yea, i think his potential daily and it somewhat is outstanding!
Q: What does the cable ZR-YJV22-4 * 16 mean?
Copper core flame retardant XLPE insulated PVC sheathed power cable, three core, 6 square

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches