600/1000V XLPE Insulated Fire Resistent LSZH Power Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Brief Introduction
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE power cable has high electric strength, mechanical strength, high-ageing resisting, environmental stress resisting anti-chemical corrosion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
The flame-retardant and non-flame retardant XLPE cable can be manufactured with three technologies (peroxide, silane and irradiation cross-linking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke non-halogenated and three classes of A,B,C.
Product Description:
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 6/10kV 8.7/15kV 26/35kV.
4. PVC or PE sheathed.
5. Number of cable cores: one core(Single core),two cores(Double cores),three cores,
Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),
Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
6. Standards: IEC 60502. IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.
Application Conditions
1. The long-time permissible operation temperature of conductor shall not be higher than 90oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 250 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5. Light weight, perfect bending properties, installed and maintained easily and conveniently.
Specification
Type | Designation | Applications |
YJV YJLV | Cu conductor, XLPE insulated, PVC sheathed power cable Al conductor, XLPE insulated, PVC sheathed power cable | For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. |
YJY YJLY | Cu conductor, XLPE insulated, PE sheathed power cable Al conductor, XLPE insulated, PE sheathed power cable | |
YJV22 YJLV22 | Cu conductor, XLPE insulated, steel tape armoured, PVC sheathed power cable Al conductor, XLPE insulated, steel tape armoured, PVC sheathed power cable | For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 YJLV23 | Cu conductor, XLPE insulated, steel tape armoured, PE sheathed power cable Al conductor, XLPE insulated, steel tape armoured, PE sheathed power cable | |
YJV32 YJLV32 | Cu conductor, XLPE insulated, steel wire armoured, PVC sheathed power cable Al conductor, XLPE insulated, steel wire armoured, PVC sheathed power cable | For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJV33 YJLV33 | Cu conductor, XLPE insulated, steel wire armoured, PE sheathed power cable Al conductor, XLPE insulated, steel wire armoured, PE sheathed power |
- Q: Wire inside the two lines, red and black, black line is the line of fire or zero line ah?
- Narrow only includes standardized fasteners Domestic standard parts are commonly referred to as standard fasteners, is a narrow concept, but can not rule out the existence of broad concept In addition there are industry standard parts, such as automotive standard parts, mold standard parts, also belong to the general standard parts
- Q: I need to drill into the doorframe which is pre fabricated pressed metal and I don't want to drill into the electrical wires . Is there any chance I could drill into them .
- you should have two 2x4s on both sides of the doorway and a header at the top. If you look where your light switches are, they should be four to four and one half Inch from the inside of the door jam. That's where the wires run through the ceiling and from the floor. So the answer is that you can drill as many holes in your door jam as you want.
- Q: I saw a show about how it can affect the way you feel temperature, and light touches. There were a few cases in which the electrical wiring needed to be fixed, and that ultimately resolved the situation of the supposed paranormal. Anybody experienced this?
- Phyrekis,Ruling out any electrical problems,they do say that spirits are attracted to electromagnetic fields.Most paranormal investigators use an EMF detector to find these fields to rule out these fields that are generated by lights,pipes and any electrical appliances.Most feel when the temperature drops in a room it can indicate a spirit that has manifested it's self.Often there will be cold spots.I've had several experiences over my life time and when a spirit is present you can actually feel a coldness and the hairs on your arms can stand up.That's why investigators try and get readings in a room to rule this out first before they come to any conclusion that this could be spiritual. Tomb Raider
- Q: I am installing an electrical socket on the backside of a wall that already has an electrical socket. Does the electric wiring have a minimum length that I can cut it to or can I go as short as 3 feet?
- In some cases the shorter the better so I would not worry about the length go ahead and make it 3 feet.
- Q: Hi I am installing a pool pump. The pool pump requires a 14 awg and a 15 amp breaker. We have the wires and the breaker but a friend says since we are running it about 80 ft away from the pool it will lose power. What should we do?
- Go on up to a number 12 and keep the 15 amp breaker. The footage does not become an issue for another 50 feet so keep with code and return the 14 and don't worry about the breaker you do not want to increase the size just because you increase the size wire. the motor is the load and will be protected just fine with the 15.
- Q: It hurts, and then you will be detours later, but the poles are still there! What is the original statement of that sentence! The More
- If there is a group of two groups of weak lines, in order to prevent interference, should be more than 200mm distance, the specific requirements should be based on the scope of electromagnetic fields.
- Q: I have a Pioneer DEH-P6600 CD player. I want to connect a rockford detonator 220 W, 4ch (Model# AMP326) to it. The sub is a single 10 inch MA audio. I would also like to make sure I know how to do it so if you could run me through that as well that would be great. I also want to know if electrical wire is safe. Please help as soon as you can. It would be nice to know by the holidays! Thanks!
- If you're talking about those cords on your lamps or TV's, they'll work as speaker cables for small systems. But you should get decent speaker wires for something like yours or bigger systems.
- Q: If I had a 2D shape like a star bent from a single length of wire, how could I 'electrify' it - i.e. pass an electric current through it? I assume that I can't just join the ends straight to the 1.5v battery.I am trying to create a magnetic field and wonder what shape it would have. Would it matter if the wire touched itself as it kept crossing over itself?
- They make TVs just for Hotels. But as for security, usually a wall mounted with a pull down feature. The wall mount will be bolted to the back of the unit. Cant fit a socket and ratchet/hand back there to unbolt it. Swivel it down to unbolt it but having a lock built in or put a lock in a place where it will jam it tryed to be swiveled.
- Q: I have a electrical outlet in my room on a switch. I want to divert the wires in the attic so that I can install a ceiling light.The duplex electrical outlet has black, white, red, and ground wires attached. The wall switch has black, red, and ground attached. I connected black, red, and ground from the switch to my ceiling light. It does not work. What am I doing wrong? Thanks.
- Only half of the outlet is switched, usually the top. The white is a neutral and feeds both top and bottom. If you look at the metal on the side of the outlet you will see that there is a break in it between the black and red screw but no break on the white side.To figure out which wire is switched insert a tester into the outlet with the switch off. When you determine which color stays hot then the other is the switched wire.To wire the light to the switch, use the switch wire and the white.
- Q: can we replaced it with the normal plastic insulated wire?
- Only old appliances did this, and they probably had a lot of a now banned substance, asbestos, in them to handle the heat.
Send your message to us
600/1000V XLPE Insulated Fire Resistent LSZH Power Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches