600/1000V XLPE Insulated Fire Resistent LSZH Power Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Brief Introduction
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE power cable has high electric strength, mechanical strength, high-ageing resisting, environmental stress resisting anti-chemical corrosion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
The flame-retardant and non-flame retardant XLPE cable can be manufactured with three technologies (peroxide, silane and irradiation cross-linking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke non-halogenated and three classes of A,B,C.
Product Description:
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 6/10kV 8.7/15kV 26/35kV.
4. PVC or PE sheathed.
5. Number of cable cores: one core(Single core),two cores(Double cores),three cores,
Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),
Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
6. Standards: IEC 60502. IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.
Application Conditions
1. The long-time permissible operation temperature of conductor shall not be higher than 90oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 250 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5. Light weight, perfect bending properties, installed and maintained easily and conveniently.
Specification
Type | Designation | Applications |
YJV YJLV | Cu conductor, XLPE insulated, PVC sheathed power cable Al conductor, XLPE insulated, PVC sheathed power cable | For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. |
YJY YJLY | Cu conductor, XLPE insulated, PE sheathed power cable Al conductor, XLPE insulated, PE sheathed power cable | |
YJV22 YJLV22 | Cu conductor, XLPE insulated, steel tape armoured, PVC sheathed power cable Al conductor, XLPE insulated, steel tape armoured, PVC sheathed power cable | For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 YJLV23 | Cu conductor, XLPE insulated, steel tape armoured, PE sheathed power cable Al conductor, XLPE insulated, steel tape armoured, PE sheathed power cable | |
YJV32 YJLV32 | Cu conductor, XLPE insulated, steel wire armoured, PVC sheathed power cable Al conductor, XLPE insulated, steel wire armoured, PVC sheathed power cable | For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJV33 YJLV33 | Cu conductor, XLPE insulated, steel wire armoured, PE sheathed power cable Al conductor, XLPE insulated, steel wire armoured, PE sheathed power |
- Q:Hi,I am looking at installing a 8l fridge between the seats of my 4x4 ute, as it doesnt have a console. The problem is that i dont know exactly how to wire it up the way i want. I want to install a 12v plug through a rocker switch, so that when the switch is off, the power to the 12v plug is only on when accessories is on with the stereo etc. But i want it so that when the switch is flicked on, the power to the 12v plug is constantly there, whether the key is on or not, and the blue led in the switch is on as well. is this possible? sorry if it is confusing.thanks for any help
- Your best bet is to find a power source at your fuse block and find a spot that has power when you just have the accessories on. that way the power is on with accessories and off when you turn off the ignition. Hope this helps out?
- Q:What are the test requirements for the power cord?
- Yellow, green, red three colors, or called A, B, C three, or U, V, W phase, is the corresponding, three-phase voltage are 220V, line voltage of 380V, if the load is not balanced , Easy to burn the line. Hope to help you busy, man is a hydropower engineer, what questions, though looking for me.
- Q:Hi Everyone,I live in California. So this is for a California home.I am trying to hook up ceiling fan. The Ceiling fan has two colors: White and black.However, the electrical wire to the house outlet has the following colors: Red, White, and Green.I believe Green is ground. So, would the wire pair connections be:Red-BlackWhite-WhiteGreen - Fan unit chassisAnd input would be great!Thanks!
- Be careful, as you never know what wires were hooked to what. That convention sounds right, but not everyone follows convention. Yes, the green is ground, and it usually connected to a green screw in the appliance meant for that purpose.
- Q:How much per square bus load, how many watts
- In the distribution box to open a bridge with a cross-section of the size of the square hole, the bridge into the line on the line.
- Q:I tried to replace an old outlet with a new one today and I accidently put the white wire into the slot for the black wire and vice versa. I used one of those quickwire outlets. When I turned the power back on, smoke started coming out of the outlet and now all the outlets in my room and in the nest room don't work. What exactly happened and what do I do now?
- You swapped the hot neutral wires coming from your circuit breaker to the outlet you worked on, and other outlets in your room. Not to worry too much - it's repairable. 1. make sure the circuit breaker popped open (or the fuse blew open.) leave alone until step 9. 2. use a voltmeter at your outlet and make sure there is no power carried to the outlet. You should set the meter to AC (alternating currrent) and in the US, the scale you select should be greater than 220 Volts (less than 220 V could fry the meter.) If you have an auto-ranging DVM (digital voltmeter) it will set itself. Plug the black wire into Ground and Red wire into VAC on the meter. To measure the voltage, plug the black wire into one of the wide slots and the red wire into the other wide slot -- you should not measure any voltage. 3. pull out the outlet from the wall and remove all 3 wires, including the ground. I would throw away the outlet and get a new one. 4. check the wires and cut-off any burned insulation, and strip insulation off about 3/8 of an inch. Form each wire into a small question mark shape - a clockwise-facing open loop. 5. attach the bare copper wire (ground) to the green grounding screw, located at the bottom by itself. 6. attach the white wire to the silver screw 7. attach the black wire to the brass screw 8. Reinstall the outlet into the box and coverplate. 9. Reset the circuit breaker (or replace the burned fuse with exact same value.) 10. Use your voltmeter to check power at the outlet. You should measure 110 V across the two blade openings in the outlet. You are good to go.
- Q:Why the wire cut there are many ash, and the copper wire is very easy to break
- Power cable placement capacity of the bridge cross-sectional area of 20%, control cable for the cross-sectional area of 50%
- Q:fore an electric stove of 3000 watts, taking into consideration that the voltage in my country is 220volts
- Follow the link below and go to the theory page. It has all the formulas necessary for you to find what you're looking for. Good luck.
- Q:Rural new house. Do not know is to choose BVV line. Or the first BV line is ready to buy 1.5 square feet. Lighting with 2.5 square feet. Socket 4.0 square main line of electrical appliances are washing machines. Air conditioning and other commonly used appliances ... Let 's get ready to go straight
- Wiring this problem depends on how much of the current you want to use the general 10 square below the wire per square (aluminum) can pass 5 current (copper line l, but I are using copper per square 5 current) current Generally on the school should be considered P = IU (P power I current U voltage
- Q:What is the role of the two-color wire and monochrome wire?
- 1. Birds are just standing on a wire can not form a loop so there is no electric shock. 2. Birds feet from the distance even in the high voltage line will not form a step voltage.
- Q:That is now the new house has that position in the living room sofa wall mosaic of a small iron box, about 40 × 25 cm, which there are many wires called the box? Know friends say ~ thank you! More
- laying in the metal trunking is only the cable itself (not through the tube)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
600/1000V XLPE Insulated Fire Resistent LSZH Power Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches