• Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2 System 1
  • Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2 System 2
  • Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2 System 3
  • Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2 System 4
  • Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2 System 5
  • Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2 System 6
Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2

Single Core PVC insulated and PVC sheathed SDI Cable as per AS/NZS 5000.2

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

PVC SDI cable for Australia market 450/750V to AS/NZS 5000.2


Applications:

Double insulated, easy-peel sheath for general wiring, unenclosed, in conduit, or in underground ducts for domestic, commercial and industrial installations where not subject to mechnical damage. Suitable for glanding.



  • Rated voltage: 450/750V

  • Conductor: Copper 1~16 mm2

  • Insulation: PVC, V-90. Black or Red

  • sheath: PVC, 3V-90. White

  • Environmental performance: Normal operating temp. 75℃

  • Standards compliance: AS/NZS 5000.2

  • OEM can be available

  • Remark: Flame retardant or fire resistance or Low Smoking and Halogen free or other property can be available


Parameter sheet





Production  facility



Main Quality Inspection Equipment

Sparker tester,Heating aging Chamber,High resistance machine, Oxygen index equipment, Partial discharge inspection instruments, Fireproof testing device,High-power voltage withstand tester,No-rotor Vulkameter,Pull tester,Analytical balance,Direct current bridge,Plastic tester,Projector, Punch machine,Cross-linked cutting machine,etc.




Company Overview





Certificates



Q: I am trying to change the electrical box to a ceiling fan box. House built in 1959. 4 wires are in the old box 4 white wires are sodered together from 3 of the wires. And one white and 3 black wires are sodered together. I can't take the box out until I cut the wires. What do I do after that? I have a picture I can send.
Why can't you just put a 2X4 support over the box that is there? If that old box is supported with a bar hanger it will support a fan.
Q: 16 square millimeters of wire how rough how to calculate
According to the norms of the words can not. A line of a tube, unless the control line and then wear a tube no problem. Air conditioning line is not very standardized, according to the provisions should be 16 square below, are the same diameter. But the words of their own home can be used. Specifically to see how you set the.
Q: Upstairs toilet water seepage for a long time, my house is a large number of walls, has been unable to discuss the argument, the recent short circuit, and suspected to be the reason for water seepage, but upstairs and his insistence, even if there is a leaking can not affect wire. Because of this ignorant, so here to ask you, leakage of water will lead to short wire inside the wall? Thank you for answering. Question added: 1: is the old house, the wire is replaced seven years ago. 2: upstairs tenants insist on not admit leaking, but also invited his decoration master to see, they say no matter what the situation, even if the water leakage will certainly not lead to short circuit. For his argument doubt, so I would like to ask, is not any case, the leakage of water will not be inside the wall bubble to a short circuit? More
If your wire in the thread when the insulation will break even if it is a little bit, or the existence of quality problems with the wire encountered when the water or moisture will cause a short circuit. (Upstairs tenants do not admit that the water is not admitted, but also invited his decoration master to see, they say no matter what the situation, even if the water leakage will certainly not lead to short circuit.) Is his decoration master? Funny right? First of all, you have to find a professional electrician master to let him use [shake table] or megger to detect whether the line there is a short circuit phenomenon, if there is upstairs in the upstairs and then check, and then consult.
Q: Hi, My house has a wire for a light sticking out of the wall on the outside of the house. Problem is that there is no electrical box, so I have nothing to mount my light too. The outside is wood. Does anyone have any suggestions, that will work, and is safe? Thanks for your timepb4sc
The box that the wire comes too should be mounted inside the wall. The box will have the mounting holes for most fixtures. Be sure to use a gasket between the box and the cover.
Q: How does calculating the number of wires in the construction budget? What line need to take the root number, what line does not need to take the root number?
It is recommended that you buy a TV card price of 100 yuan, with it can watch TV on the computer, it also has a collection function, you can simulate the signal directly to the computer to become a DVD or VCD MPG file, such as the gallbladder There is a need to make a disc. It is recommended to buy PHILIPS chip
Q: If I take 5 wires, all with their own insulating sheath, twist the wires on both ends, will this work as if all the wires were in one single sheath? Will the conductivity combine as if it's one wire in one sheath? Note I'm taking about a 1000 foot line one way.
The theory is good but the practicability just ain't gonna work.just think about what you have written for it to work the wires would have to be twisted the entire length and then sheathed. what do you think you will drive at the end. Time to engage an electrician.
Q: i don't have any more information science class-extra creditt THANKS A MILLION
Copper. It's cheap. It conducts a current (electrical wires) and retains heat (pots and pans).
Q: Going by the chart of wire sizes and how many amps different sizes can handle, here's my question. I see a # 10 guage wire can hold 30-35amps. However, can it hold more amps if it were being used for the neutral?
Your hot and neutral need to be the same size wire, your ground wire can be smaller.
Q: I have a small John Deere tractor i keep at my lake lot. I have a big problem with rats chewing up the wiring. They have gone as far as getting into storage shed, get into the range cubes i keep for cattle feed and make a nest under the hood of the tractor.Is there any kind of electrical tape to wrap the wires with to keep them away. They chew not just threw the insulation, but even the copper wire.
Hi there. I had the same problem near my barn The oly thingthat worked was rat traps and rat bait. But becareful whne you go to use the tractor afterwards. I forgot about a rat trap it hit the cooling fan and . bits of rat flew everywhere I have heard that tractor supply sell a spray for this but i have never been able to find it.
Q: I know what the hot wire and ground wire are but why do you need a neutral wire? The hot wire is black and the ground is green right? So neutral is white? My bigger question though is why do you need a neutral wire--what is its purpose? Thank you!
The neutral is the return for the electricity, The ground is not to be used for this, for safety reasons, it must go to ground. They are not supposed to be connected together the neutral and the ground, although, in some older wiring systems this is the case. In newer installations they are separated. Edit: For the person who says that the neutral is connected to the ground at the service entrance that is incorrect, go read your code book again, I've installed every thing from 3 phase on down and never are the neutral and ground connected.