• 35kV or Lower XLPE Insulation low smoke& halogen-free flame-retardant Termite-retardant Power Cable System 1
  • 35kV or Lower XLPE Insulation low smoke& halogen-free flame-retardant Termite-retardant Power Cable System 2
35kV or Lower XLPE Insulation low smoke& halogen-free flame-retardant Termite-retardant Power Cable

35kV or Lower XLPE Insulation low smoke& halogen-free flame-retardant Termite-retardant Power Cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.      Application

This product is suitable for termite damage zone in power plants, power stations and long-distance power transmission systems, especially in the high environmental requirements and pipe laying of underground power lines termite. 


2.      Type and Specification

Voltage

6/6 kV、6/10 kV、8.7/10 kV、8.7/15 kV、21/35 kV、26/35 kV

  Type

FYS-WDZ-YJY、FYS-WDZ-YJY23、FYS-WDZ-YJY33、FYS-WDZ-YJY42、FYS-WDZ-YJLY、

FYS-WDZ-YJLY23、FYS-WDZ-YJLY33、FYS-WDZ-YJLY42

Size

(mm2)

1 Core: 25~1000;

3 Core: 25~500

Standard

Q/XLJ 0348


3.      Using features

①      Rated voltage Uo/U includes 0.6/1kV, 1.8/3kV, 3.6/6kV, 6/6kV, 6/10kV, 8.7/10kV, 12/20kV, 18/30kV, 21/35kV,26/35kV.

②      The highest allowed operating temperature of conductor for long-term working is 90℃. In short-circuit (Max. long-term is no more than 250℃)

③      D.C. resistance of the conductor complies with the stipulations of GB/T 3956.

④      Installation ambient temperature should be no lower than 0℃. Otherwise it should be preheated. The Min. bending radius should be no smaller than 15 times of cable outer diameter. 

⑤      The cable is laid without horizontal drop limit.

⑥      Working Frequency Voltage Test::
   For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture;
   For cable with Uo of 3.6kV~18kV or lower: 3.5Uo/5min without puncture;
   For cable with Uo of 21kV and 26kV: 2.5Uo/30min or 3.5Uo/5min without puncture.

⑦      Partial Discharge Test: The discharge volume should be no more than 10Pc under1.73Uo for the cable. There shall be no detectable discharge under the declared sensitivity test.

⑧      Flame-retardant Character:

The flame-retardant characteristics comply with GB/T 1996-2005

⑨      Cable prevention of rat and Termites characteristics comply with GB / T 2951.38-1986.

 

 

4.      Picture of structure


1、Conductor  2、Conductor shield   3、Insulation   4、Insulation shield  

 5、Copper tape shield   6、Filler   7、Tape    8、Inner sheath   9、Armor   10、Outer sheath


Q:If Not What Do I Have To Look Out For Because Im Looking For A New Power Supply Fan.
Power supply fan is fan inside the power supply, which is the box inside the case of your pc that the main power cable to the pc plugs in to. Case fan is the fan inside the case that provides ventillation to the case. In some power supplies, the power supply fan will act as a case fan by sucking air from inside the case and redirecting it through the power supply then outside the case. This type of power supply is unusual though. in most situations the power supply fan does not act as a cooling system for the case. (and therefore does not act as a case fan). If you replace your power supply fan be VERY CAREFUL as they are extremely dangerous to work on because they deal with direct current from your power socket. The fans inside the PSU are attached by 4 screws to the metal enclosure. usually they are attached to the circuit board by a plug. I have teken a few to pieces and hevent seen one which requires soldering. That may be the case with some models though. USE EXTREME CARE if replacing a power supply fan!!!! Replacement power supplies are very cheap and can be picked up for about $25. If its the PSU fan, it may be simpler to just replace the unit (a new fan is by itself about $10) So for about $15 you can have a whole new unit with no risks to your machine or to your health :o)
Q:Hey guys, I noticed that with heavy use of the power cord to my laptop, a part of the rubber surrounding the cord is open near the insertion part and you can see the wires. I'm just curious how dangerous it is. I don't have another power cord for my laptop, so do any of you have a recommendation for what I can do?
The outer layer of laptop power cables below the rubber is the insulating layer. Little risk there. If you want, you can purchase electrical tape from HomeDepot or local electronics store{(probably), and wrap it around the rip.
Q:How many amphs does the us ps3 slim's power cable have? It should be #A?
i don't know why youre trying to find this out but heres a chart. The power cable has different electricity usages depending on what youre doing but the average is 87 ish
Q:the cable for my psp wont plug all the way in anymore so i cant charge it. nothing has happened to the psp. it wasnt dropped or anything, just sat on the table. same with the power cord.anyone else have this problem and if so what did u do about it.and if your thinking about saying quot;contact sonyor anything like that...just leave. i can figure that out for myself ok.
MMMM. im not sure i think you might need to buy a new one if you try to force it in you might break something
Q:Why is my 2 Gage power cable from the battery to my amp is to hot and makes a big spark and burns the wire when you meet one end to the other end?
Too hot means the current is very high. Probably in excess of 200 amps. I suspect there is a short in the amp, specially if you tried to connect it hot and drew a spark. That will kill a lot of electronics. .
Q:Electric power fittings, cable, tax classification code how to choose
Cable distribution box according to its electrical composition is divided into two categories: one is not any switch equipment, the box only the cable end of the processing and connection of the attachment, the structure is relatively simple, smaller, more functional , Can be called ordinary distribution box; the other is not only the general distribution of the box annex, but also contains one or more switchgear, its structure is more complex, larger, more connected devices, manufacturing technology Large, high cost, can be called advanced distribution box
Q:It's the newest ps2 (the thin ps2) I have all cables. Except the power cable isn't the official power cable. Is that a problem?
It's impossible to tell if it's your PS2 or the cable. Best bet is you buy an original PS2 power cable and try it out. If the PS2 still doesn't power up, it's something wrong with your PS2 and you will have to get it repaired or buy a new one.
Q:What is the difference between a YJLV cable and a VLV cable?
. you want to achieve remote switch, right? In fact, from the host side of the original fixed switch button that cut the two lines, and then then you need to extend the extension cable you can, the super simple; . Internet cafes router, through the exchange (or hub) , Can achieve port expansion capabilities, you can access a lot of computers, but the Internet speed is limited by the router exit speed, that is the maximum speed will not exceed the router exit speed, and broadband providers will be on the server side of the uplink and downlink speed (That is, to provide customers with the speed) restrictions.
Q:I have a be quiet! dark power pro 850W. The sleeving is too thick for cable management!! It is a complete mess with the antec 900. its ridiculous as I bought it with cable management in my mind. Can I buy thinner cables on their own? Is there a standard modular fitting size?Thank you.
I got the Coolmaster 1000, all the cables bar the main are disconnecting, very handy plus they supply you with all the cables you will ever need to make a monster of a system.
Q:I have a power adapter that goes to a mixer (Denon DN-MC6000) and reads: INPUT 100-240V ~ 50/60Hz 1.5A, OUTPUT: 12V - 3A. Now I know this is the right adapter but I don't know if I have the right cable that goes from the adapter to the wall. I have one that says 6A 250V~ but I dunno if its the right one. I have a few others but can someone tell me what will be the right one so I don't blow up my mixer :P thanks
Hi, The adapter to the tip is the important part. Whatever fits from the adapter to the wall doesn't have much to do with anything. Anything that fits the adapter, physically.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords