• WQ Series Submersible Centrifugal Sewage Pump System 1
  • WQ Series Submersible Centrifugal Sewage Pump System 2
  • WQ Series Submersible Centrifugal Sewage Pump System 3
WQ Series Submersible Centrifugal Sewage Pump

WQ Series Submersible Centrifugal Sewage Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

PRODUCT INFORMATION

WQ series submersible non-clog sewage pump in the introduction of foreign advanced technology, based on the joint efforts by our researchers, while a wide range of suggestions from pump experts, and after many improvements and successfully developed, tested each Top performance indicators are that the advanced level of similar foreign producing countries. Used in chemical, petroleum, pharmaceutical, mining, paper industry, cement plants, steel mills, power plants, coal processing industry, and urban sewage treatment plant drainage systems, municipal engineering, construction sites etc sewage particles, dirt, can also be used to pump clean water and corrosive media.

Model significance

50WQ (QW) 25-32-5.5

50 caliber 50mm exhaust ----

WQ (QW) --- submersible sewage pump

25 ---- flow of 25m3 / h

32 ---- lift 32m

5.5 --- with motor power 5.5KW

Performance range

Flow: 7-950m3 / h

Head: 7-35m

Features

1. When using a unique monolithic or double blade wheel structure, greatly improving the living creatures capacity, can effectively through five times the diameter of the fiber material and pump caliber pump diameter of about 50% of the solid particles.

2. Mechanical seal with anticorrosive hard softening tungsten materials, can pump more than 8000 hours of continuous operation safety.

3. The overall structure is compact, small size, low noise, energy-saving effect is remarkable, easy maintenance, no need to build pumping stations, poured into the water to work, greatly reducing the project cost.

4. The pump seal oil chamber with high precision interference leakage detection sensors embedded in the stator windings of the thermal components, automatic protection of pump motor.

5. According to user needs with automatic control cabinet, the pump leakage, leakage, overload and overtemperature protection automatically improve product safety and reliability.

6. float switch can change depending on the desired level, the automatic control of pump start and stop, without special care, extremely easy to use.

7.WQ series according to user needs with double rail automatic coupling installation system, install it to bring more convenient maintenance, may not have to get into the sump.

8. be able to use in the whole head, but to ensure that the motor is not overloaded.

9. There are two types of installation, fixed automatic coupling installation system and traveling free installation system.


FAQ

We have organized several common questions for our clients,may help you sincerely: 

①How about your company?

A world class manufacturer & supplier of castings forging in carbon steel and alloy steel,is one of the large-scale professional investment casting production bases in China,consisting of both casting foundry forging and machining factory. Annually more than 8000 tons Precision casting and forging parts are exported to markets in Europe,America and Japan. OEM casting and forging service available according to customer’s requirements.

②How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.

③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The pecific time of receiving is related to the state and position of customers.Commonly 7 to 10 working days can be served.

 

Q: Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
For example: water storage is relatively small, it needs to reduce the temperature of the heat exchanger. If the tank is relatively large, it does not need cooling water circulation pump again when the temperature is very low, there is no need to heat exchanger. So you need to ask how much water this is not OK.In a soda separator problem:
Q: Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q: Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q: What is a positive displacement pump? He Weizheng displacement?
And includes a pump chamber (24) to open and a channel is arranged between the entrance and the pump chamber (26) in the second one-way valve (15), and one for the continuous displacement member (13) in the pump shell (10) in the travel section (S) actuating mechanism reciprocating motion.
Q: Rules for operation of centrifugal pumps
5, before you stop, you should gradually close the outlet valve, then turn off the power supply.6, with the check valve line, in ensuring the check valve intact, without closing the outlet valve, check the pump cavity, no air can be directly switched on.
Q: Household automatic booster pump, how much pressure to work automatically, the water pressure and how many kilograms?
With the pressure does not matter, because the pressure is small, it is necessary to boost the pump, the water pressure with the pipe flow and the size of the booster pump related
Q: What is the difference between centrifugal pump and self suction pump? Which is better?
In order to prevent the filling liquid into the pump shell because of gravity flow in the low groove, in the pump suction pipe at the entrance of a non-return valve (valve); if the location of the pump below the liquid level in the tank, then start without irrigation pump.Self-priming pump is a self-priming centrifugal pump, centrifugal pump is a kind of.Specific choice of a pump, depending on your specific parameters and conditions of use.
Q: What are the characteristics of the piston pump?
main features 1 、 double plunger structure, small pressure pulsation, long life of gem ball.2 、 imported precious stones and precious stones to ensure accurate flow.3, through the RS232 interface and computer communication, can be directly controlled by the computer.
Q: What are the failures and causes of the replacement of the fuel pump assembly?
Failure cause:1) the gasoline pump is too thick with the gasket at the junction of the axle box.2) pump film rupture or pump film and pump shell combination of sealing is not strict.3) the oil inlet valve is stuck or sealed badly.4) severe wear of the rocker arm, reducing the pump film stroke.5) the pipeline from the gasoline tank to the gasoline pump is not smooth, or the pump film spring passes.