Vertical Multistage Centrifugal Pumps with high quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
FEATURES:
Vertical Multistage grundfos water Pump is the latest model with the features of energy-saving and less space demand, easy to install and has stable performances.
1. With its 304 stainless steel shell and wear-resistant axle seal, there is no leakage and it can live long service life.
2. With hydraulic equilibrium to balance the axial force, the pump can run more smoothly, less noise, which can be easily installed in same level pipelines, enjoying better installation conditions than DL model.
3. With these features, GDL Pump can easily meet the needs and requirements for water supply and drain foe high building, deep well and firefighting equipments.
Flow range: 1.4-1 94.4CBM/h
Head range: 20-230m
Speed: 2900r/min
Maximal pressure of system: 2.5MPa
Medium temperature: -15~°C+120°C
Environment temperature: ≤+40°C
Motor protection level: IP44, IP54
Insulation grade: B, F rank
Rotation direction: Clockwise
APPLICATIONS:
Domestic water supply for buildings
Fire water supply for buildings
Water supply equipments
Water supply for boilers
Water circulation and boosting for industry
Other clean fluid transportation
- Q: Troubleshooting of diaphragm pump
- In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
- Q: What is the Rhodes pump?
- Work principle editorRoots-type pump is a vacuum pump without internal compression, usually compression ratio is very low, so high and medium vacuum pumps need pre pump.A vacuum pump for pumping air by pumping a gas by the simultaneous rotation of a pair of lobed rotors in a pump cavity and a reverse rotation.Roots vacuum pump is a mechanical vacuum pump with a pair of synchronous and high-speed rotating sole shaped rotors. The pump can not be drawn out separately. The front stage needs to be equipped with an oil seal and a water ring, etc. it can be discharged directly into the atmosphere.
- Q: The distance from the pump button to the ground
- A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
- Q: What is the lift of diaphragm pump?
- Hello, pneumatic diaphragm pump head is liquid, the energy obtained through the pump is called the head, it is related to the flow rate and pump speed, liquid density.Please adopt.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- The dead point head is the measured head after the outlet valve is closed. Mainly on the lower reaches of the pump equipment, such as your dead center, the lift is 300 meters, that is, 3MPa
- Q: How can I buy a pump?
- Selection principle of pump:1, so that the selected pump type and performance parameters meet the unit flow, lift, pressure, temperature and other requirements, the most important thing is to determine the voltage, the maximum lift, and when the head high reached much traffic.
- Q: The working principle of magnetic pump
- Structure characteristics1. permanent magnetPermanent magnet operating temperature range is made of rare earth permanent magnet wide (-45 - 400 DEG C), high coercivity, magnetic anisotropy direction is very good, also won't happen in the same demagnetization phenomenon when is close, is a good source of the magnetic field.2. isolation sleeveIn the metal isolation, isolation sets in a sinusoidal alternating magnetic field, in a cross section perpendicular to the direction of magnetic field lines induced eddy current and converted into heat. Eddy current expression is:. The Pe - K constant; eddy current; rated speed of N - T - pump; magnetic drive torque; F - the pressure inside the sleeve; D sleeve diameter; a material resistivity; and the tensile strength. When the pump design is completed, N, T is the given conditions, to reduce eddy current only from F, D, and so on. Non metallic materials with high resistivity and high strength production isolation, in reducing the eddy current effect is very obvious.
- Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
- The valve opening pump is aimed at the centrifugal pump.From the power curve of the centrifugal pump, the power of the centrifugal pump increases with the increase of the flow rate; the flow curve of the centrifugal pump shows that the flow rate of the centrifugal pump decreases with the increase of the head.
- Q: What's the submersible pump?What is a submersible pump, and what about it?
- Deep well submersible pump is a fountain, drinking water transportation, irrigation, hot springs, high-rise transport facilities, etc., deep well submersible pump excellent performance, so widely used in various fields.
Send your message to us
Vertical Multistage Centrifugal Pumps with high quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches