Multistage Centrifugal Pump with High qualities
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
FEATURES:
Vertical Multistage grundfos water Pump is the latest model with the features of energy-saving and less space demand, easy to install and has stable performances.
1. With its 304 stainless steel shell and wear-resistant axle seal, there is no leakage and it can live long service life.
2. With hydraulic equilibrium to balance the axial force, the pump can run more smoothly, less noise, which can be easily installed in same level pipelines, enjoying better installation conditions than DL model.
3. With these features, GDL Pump can easily meet the needs and requirements for water supply and drain foe high building, deep well and firefighting equipments.
Flow range: 1.4-1 94.4CBM/h
Head range: 20-230m
Speed: 2900r/min
Maximal pressure of system: 2.5MPa
Medium temperature: -15~°C+120°C
Environment temperature: ≤+40°C
Motor protection level: IP44, IP54
Insulation grade: B, F rank
Rotation direction: Clockwise
APPLICATIONS:
Domestic water supply for buildings
Fire water supply for buildings
Water supply equipments
Water supply for boilers
Water circulation and boosting for industry
Other clean fluid transportation
- Q:How high can the pneumatic diaphragm pump be?
- If the pump material made of polypropylene (PP) material, corrosion resistance, good chemical resistance using PP material produced by pneumatic diaphragm pump can resist medium low cost, good generality, polypropylene material mainly is especially suitable for general acid-base liquid, using poly propylene made of plastic gas diaphragm pump can only withstand the highest temperature to 65 degrees, more than this number of polypropylene plastic deformation.
- Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- (1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
- Q:What does "anti pump" mean in pump operation?
- The pump again is the pump, the theory is the plugging problem can be solved, but if you are against the pump after pump has been plugging serious, and pump has been unable to solve the plugging problem, finally the worst solution is a split pipe, if the situation under enormous pressure will only exacerbate the plugging
- Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
- [suppression of pumping voltage] the general use of the installation of absorption resistance to absorb the pump voltage rise. The simplest way to control the pump voltage is to connect the DC bus with an energy consumption resistor before releasing the pump voltage.
- Q:How to install, operate and maintain the pipeline booster pump?
- When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
- Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
- Centrifugal pump cavitation phenomenon how to solve?:Measures to improve cavitation resistance of centrifugal pumps(1) improve the design of the suction port of the centrifugal pump to the impeller. Increase flow area; the radius of curvature increases the impeller cover inlet section, reduce the flow accelerated sharply with pressure; reduce the thickness of the blade, and the blade inlet rounded, close to the streamline, can also reduce the acceleration and pressure flow around the blade head portion of the impeller and the blade inlet part; improve surface finish in order to reduce the resistance loss; the blade inlet edge extends to the impeller inlet, the liquid flow in advance to accept work pressure, improve.
- Q:Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- 2. displacement and flowDisplacement refers to the pump (or motor) every turn a week, by the size of the sealing chamber geometry variable discharge (or enter) the volume of liquid, commonly used unit is ml/r (ml / rev). Displacement can be changed as a variable pump (or variable motor), and the displacement can not be changed into a quantitative pump (or a quantitative motor).Actual flow is the amount of flow at the outlet (or inlet) when the pump (or motor) is operating. As the pump itself leaks, the actual flow is less than the theoretical flow. As the motor itself has an internal leakage, to achieve the specified speed, in order to compensate the leakage, the actual flow of input must be greater than the theoretical flow.
- Q:Is the flow meter in front of the pump or after the pump?
- After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better
- Q:I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
- Installation method of hydraulic pump(1) according to the technological requirements and the cavitation conditions of the pump, the installation height check and the civil engineering of the foundation are carried out.(2) prepare a series of flat washers and wedge gaskets of different thickness before installation.(3) according to the characteristics of the pump conveying medium, determine the material of the gasket at the connection and process the gasket.
- Q:Brief description of centrifugal pump on / off operation
- (3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Multistage Centrifugal Pump with High qualities
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches