Variable Frequency Drive 11KV 1000KW VFD VSD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Introduction
High-voltage frequency converter based on H bridge series units. High voltage inputs directly. In order to save energy, phase-shifting transformer inputs the low voltage on the second side to each power unit of H bridge and the output series of each phase and all power units connect so it has formed high voltage to drive the motor that. It’s a high-tech, green energy-saving product integrating advanced automatic control technology, high-power electric and electronic technology, fast and reliable fiber communication technology, high voltage technology and digital signal processing technology.
Quality Warranty
We hereby warrant that the new instruments manufactured by the Company are strictly tested for quality, and that we assume the responsibility for free repair if any engineering defect or part fault is found within 1 year of delivery of the instrument.Within one year warranty, please send your faulty unit to the company's service center or designated dealer for proper repair.We, however, provide no free warranty service for any damage caused due to user's modification of circuit, function or repair of the instrument and parts or damaged package. This warranty does not apply to such accessories as auxiliary devices to this instrument which are not produced by the Company.
If this unit is faulty due to misuse, human negligence or force damage factors such as earthquake, flood, riot or fire hazard,the company provides no free warranty service.
Specification
Model | A03/050~ | A03/100~ | A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40°C | ||||
Storage/transport temperature | -40~70°C | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 | 4900×2480×1200 | 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- Three-phase two-pole motor running inverter protection, should be based on the protection of tips, check the corresponding manual to deal with. When the inverter protection has a corresponding protection tips (such as over-current, over-voltage, speeding, stall ... ... etc.), the product manual will generally give the corresponding protection tips. According to these measures to check, deal with, you can solve the problem.
- Q: Is the inverter output current proportional to the output torque?
- When 50HZ or more, the voltage is not increased, the magnetic flux decreases. P = T * n / 9550, if the motor output torque does not change, the current will increase, the motor heat overload
- Q: Laptop power adapter bad what is the phenomenon?
- Either the power is bad or the machine on the power supply module is bad to repair service
- Q: How to lift Yaskawa inverter base blockade?
- Note: the base blockade is to deal with ul or ce such a special application of security agencies, meaning that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop loop more harsh, they will directly cut off the power power supply. In fact, it is a white protection function, if we are not difficult to find the analysis, when over-voltage or undercurrent, the panel will show BB alarm, BB is the base block, is the base blockade.
- Q: The laptop's power adapter is broken how much it costs
- Buy a new, new price of dozens to one hundred. Notebook adapter, as long as the output current is greater than the old, the same voltage, with the brand can be interchangeable, Different brands of adapters to meet the above requirements, that is, insert the notebook connector is different, you can use scissors + tape,
- Q: What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
- So that mainly depends on your application and the frequency of work in the number.
- Q: Will the laptop's power adapter is not the original good?
- Theoretically can be inserted into the use and will not have any obvious damage to the machine But it is best to buy the number of volt and your original consistent Original also has original benefits According to some "professional" sources claim that no original touchpad will have a slight jitter, I was not found
- Q: B2b frequency how to speed
- How does changing the power frequency to change the speed of the motor? When the motor is connected to the power supply to drive the normal operation of the load, at this time to change the power frequency, such as the current frequency down, the motor armature rotating magnetic field speed will decline, the rotor conductor cutting magnetic field speed decreases, turn from the induced potential , The rotor current decreases, the torque decreases, the load on the shaft does not change, the torque will be less than the load resistance torque, the motor rotor speed decreases, the rotor conductor cutting the magnetic field line speed increases, the rotor induced potential increases, the rotor current increases, The torque rises until it is equal to the load resistance torque, and the speed is smaller than the original. After stabilizing the work, the torque of the motor is the same as that of the original. (The motor torque is the same as the load torque, the load is constant and the motor torque is not changed)
- Q: Motor a speed, the inverter will burn what is going on, the inverter is a large yuan
- Note that the quality of the inverter is not ye, and now this situation is already very rare, it is recommended to replace the inverter brand, you can use Bosch Rexroth, the British Witten, Huichuan, Senlan, Haili Pu, Ou Rui, etc. Branded.
- Q: 380V 2 pole motor can use the inverter?
- Special attention, variable frequency motor with the ordinary different, easy winding film damage
Send your message to us
Variable Frequency Drive 11KV 1000KW VFD VSD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches