Variable Frequency Drive 6KV 400KW VFD VSD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
High Voltage 3KV ~11KV AC Driver Inverter
General
CNBM high Voltage Variable Frequency Drives are designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Specification and advantages :
1. Voltage resource VFD, direct input of 3,3.3,4.16,6,606 and 10 kV,direct output of3,4.16, 6,6.6 and10 kV,no output transformer necessary. High input power factor, low harmonic current, no power factor corrective capacities and harmonic filters required.
2. Sinusoidal multi-level PWM output waveform, no output filter required, can be directly connected to standard induction motor,no harm to the insulation of the cable or the motor, low harmonics of the motor, reduction of vibration of the shafts or the vanes,with the maximal length of the output cable of 1000m.
3. Friendly human-machine interface.
4. Modular design of the power circuits simplifies maintenance routine.
5.The medium voltage circuits are linked with the controller by the optical fibers,which keep the controller safe and away from the disturbance.
6. The complete fault monitor circuit, accurate fault alarm and protection.
7. Integrated cooling blower
8. The control logic can be conveniently changed with the help of the integrated PLC.
9. Offer both field control and remote control in monitor station, providing convenient controlling options.
10. Support most of the industrial standard protocols (Profibus, Modbus, TCP/IP, etc.)
11. Compatible with industrial standard signal of 0-10V/4-20mA
12. Able to operate at either open loop control or closed loop control status with the integrated PID regulator.
Specification
Model | A03/050~ | A03/100~ | A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40°C | ||||
Storage/transport temperature | -40~70°C | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 | 4900×2480×1200 | 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
- Q: What is the number of parameters of the motor frequency of the Siemens inverter?
- Siemens inverter motor pole number parameter code is r0313 motor pole pairs. Note that the number of pole pairs.
- Q: East yuan 7200GS inverter start 11KW 4-pole motor and 2-pole motor need to modify what parameters?
- If you use the environment is relatively poor, it is recommended that you use Austrian St. sealed inverter, this inverter can be moisture, dust, water, oil, corrosion.
- Q: Notebook power adapter on how to look at power
- It should be noted that there are many in Japan to buy a notebook or over there in the parallel imports, input only support 110V in China is not used, because the Chinese standard is 220V. Now the subject is 90W 20V. Output voltage and power will be identified, such as the target for the 90W 20V, that output power is 90W, the output voltage is 20V. If only the output voltage and output current are identified,
- Q: Is the speed of the motor controlled?
- Armature for the cast steel made of cylindrical structure, which is connected with the squirrel cage induction motor shaft, commonly known as active part; Pole made of claw-shaped structure, mounted on the load shaft, commonly known as the moving part. The active and slave parts are mechanically free of any contact.
- Q: Inverter signal line analog 4-20mA connection positive and negative can be reversed?
- Analog input signal is particularly vulnerable to external interference, so the general use of twisted shield as a signal line; and wiring as short as possible, generally not more than 20 meters; if some use conditions are vulnerable to external serious interference, the analog signal Side need to add a filter capacitor or ferrite core.
- Q: Is the inverter output current proportional to the output torque?
- When 50HZ or more, the voltage is not increased, the magnetic flux decreases. P = T * n / 9550, if the motor output torque does not change, the current will increase, the motor heat overload
- Q: Laptop power adapter (no power supply, but indicator light)
- Notebook power adapter can not charge, but the indicator light does not light the common reasons are: 1, the power adapter is broken or the connector is broken. 2, the power adapter output problem, no output or output is too low, can not give the computer charge. 3, the notebook charging interface is broken, not into the electricity charge. 4, the notebook power management circuit out of the fault, resulting in can not charge.
- Q: Abb inverter s510 with water circulation pump why the motor fever. The motor is 2 pole
- Whether the motor is abnormal roar, if any, you can adjust the inverter parameters in the motor carrier frequency
- Q: What is the principle and implementation of the inverter?
- AC-DC is relatively simple We know that the diode has a one-way conductivity You can use this feature of the diode into a bridge So that the other end is always flowing into the other end is always out of the way it gets the voltage sinusoidal change of the DC If the need for smooth DC also need to be rectified Simple method is to connect a capacitor
- Q: Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
- May be mechanical part of the card, try idling motor.
Send your message to us
Variable Frequency Drive 6KV 400KW VFD VSD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches