Pure Wave Sine Power Inverter with Charger
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Units unit
- Supply Capability:
- 100000 Units per Month unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1) High efficiency
2) Quickly Response
3) Strong load compatibility & stability
4) Over-current & short-circuit protection
5) Built-in fuse
6 ) Low voltage & overload protection
7) Small profile, light weight, green sound
Technical Parameters:
Model | 100W | 150W | 300W | 500W | 1000W |
Rated power | 100VA | 150VA | 300VA | 500VA | 1000VA |
Max power | 200VA | 300VA | 600VA | 1000VA | 2000VA |
Conversion Efficiency | ≥90.5% | ||||
Input voltage | 12V or 24V | ||||
Low voltage range | 12V(10V0.5V)-24V(20V±0.5V) | ||||
High voltage range | 12V(15V±0.5V)-24V(30V±0.5V) | ||||
Overheat rang | 60±20% | ||||
Output voltage | (220V±10% or 110V±10%) changeable | ||||
frequency | (±3Hz/60Hz±3Hz) | ||||
Output waveform | Modified sine wave | ||||
Input | AC110V-240V | ||||
Output voltage(Charge) | 13.8V Output±10% | ||||
current(Charge) | 10A-40A | ||||
Dimension(mm) | 125*70*46 | 125*70*46 | 140*87*47 | 190*95*55 | 315*190*70 |
Weight(Kg) | 0.36 | 0.4 | 0.64 | 0.97 | 2.42 |
Packing | Blister card | Blister card | Blister card | paper box | paper box |
CTN (PCS) | 40 | 40 | 36 | 32 | 8 |
Net weight(Kg) | 15 | 15 | 24 | 32 | 20 |
Gross weight(Kg) | 16 | 16 | 25 | 33 | 21 |
Outside box Dimension(cm) | 51*39*39 | 51*39*39 | 51*39*39 | 51*39*39 | 54*39.5*55.5 |
- Q: How to choose the right inverter?
- 2, constant torque load Constant torque load equipment requires low frequency inverter torque, dynamic response speed. Inverter 0HZ vector state, to 150% of the torque, to meet the needs of various conditions. For example: a dredger owner bucket inverter system, is a constant torque load, dual motor, and the load overload time is long, so the inverter configuration configuration to enlarge the two models of the G-type machine, while the power supply for the device Machine power supply, the inverter must be configured to input AC reactor.
- Q: Ordinary 4-pole motor Under the control of the inverter, the higher the speed, the higher the power or the slower the power
- P = UI, that is, power = voltage × current. That is only the voltage of the motor will be faster, so the higher the speed the greater the power
- Q: Pump frequency converter instantaneous restart and restart the problem
- Speed tracking start, with them better. Speed search time is less than the free downtime, not too small too much, will be over-voltage protection. I do not understand and contact me. Your inverter voltage level, manufacturers.
- Q: Acer laptop power adapter
- If the computer on the trouble, it is safe on the motherboard, but not for the motherboard for another power on the line,
- Q: Variable frequency pump pressure in the very low flow instability, why?
- From the performance curve, the flow becomes smaller, the combination of pressure and frequency adjustment flow will only stabilize the flow at a small value, the pressure will be reduced, because the work point will move down.
- Q: Notebook plug in the power adapter lights, but can not open the machine
- This is a contradictory problem: First, the power adapter lights because the power is good, but does not mean that the computer is good; Second, can not open the machine with the power adapter is lit, it is your computer reasons. Recommendation: Check the computer hardware. Asked: But the battery can be used to start ah answer: Remove the battery plug in the adapter or put the battery installed plug in the adapter, if you can not open the machine, then it is a hardware conflict. The solution to the hardware conflict is that you try another adapter. Asked: the battery removed to die, but as long as there is a battery can answer: it shows that your adapter is bad. Asked: the more magical is plug in the adapter and the battery, the battery will not consume Answer: get you electronic city so that they give you a test. You can say to buy an adapter, and then try, you can use the words to buy, can not use the words and then think of other methods.
- Q: Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
- It should be the inverter problem, I have encountered before, followed by the inverter upgrade was resolved. Is to replace a set of power board, power board, CPU board.
- Q: How to make the motor speed (control speed), can not use frequency
- In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.
- Q: Is the laptop power adapter hot?
- Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.
- Q: First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
- And the inverter is connected to the positive and negative bk-dk electrical Han Han device,
1. Manufacturer Overview
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2012 |
Annual Output Value | Below US$1 Million |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shenzhen |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | Below 1,000 square meters |
No. of Production Lines | 4 |
Contract Manufacturing | OEM Service Offered |
Product Price Range |
Send your message to us
Pure Wave Sine Power Inverter with Charger
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Units unit
- Supply Capability:
- 100000 Units per Month unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords