• Pure Wave Sine Power Inverter with Charger System 1
Pure Wave Sine Power Inverter with Charger

Pure Wave Sine Power Inverter with Charger

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Units unit
Supply Capability:
100000 Units per Month unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

1) High efficiency

2) Quickly Response

3) Strong load compatibility & stability

4) Over-current & short-circuit protection

5) Built-in fuse

6 ) Low voltage & overload protection

7) Small profile, light weight, green sound

 

Technical Parameters:

Model

100W

150W

300W

500W

1000W

Rated power

100VA

150VA

300VA

500VA

1000VA

Max power

200VA

300VA

600VA

1000VA

2000VA

Conversion Efficiency

≥90.5%

Input voltage

12V or 24V

Low voltage range

12V(10V0.5V)-24V(20V±0.5V)

High voltage range

12V(15V±0.5V)-24V(30V±0.5V)

Overheat rang

60±20%

Output voltage

(220V±10% or 110V±10%) changeable

frequency

(±3Hz/60Hz±3Hz)

Output waveform

Modified sine wave

Input

AC110V-240V

Output voltage(Charge)

13.8V Output±10%

current(Charge)

10A-40A

Dimension(mm)

125*70*46

125*70*46

140*87*47

190*95*55

315*190*70

Weight(Kg)

0.36

0.4

0.64

0.97

2.42

Packing

Blister card

Blister card

Blister card

paper box

paper box

CTN (PCS)

40

40

36

32

8

Net weight(Kg)

15

15

24

32

20

Gross weight(Kg)

16

16

25

33

21

Outside box Dimension(cm)

51*39*39

51*39*39

51*39*39

51*39*39

54*39.5*55.5

Q: How to choose the right inverter?
2, constant torque load Constant torque load equipment requires low frequency inverter torque, dynamic response speed. Inverter 0HZ vector state, to 150% of the torque, to meet the needs of various conditions. For example: a dredger owner bucket inverter system, is a constant torque load, dual motor, and the load overload time is long, so the inverter configuration configuration to enlarge the two models of the G-type machine, while the power supply for the device Machine power supply, the inverter must be configured to input AC reactor.
Q: Ordinary 4-pole motor Under the control of the inverter, the higher the speed, the higher the power or the slower the power
P = UI, that is, power = voltage × current. That is only the voltage of the motor will be faster, so the higher the speed the greater the power
Q: Pump frequency converter instantaneous restart and restart the problem
Speed tracking start, with them better. Speed search time is less than the free downtime, not too small too much, will be over-voltage protection. I do not understand and contact me. Your inverter voltage level, manufacturers.
Q: Acer laptop power adapter
If the computer on the trouble, it is safe on the motherboard, but not for the motherboard for another power on the line,
Q: Variable frequency pump pressure in the very low flow instability, why?
From the performance curve, the flow becomes smaller, the combination of pressure and frequency adjustment flow will only stabilize the flow at a small value, the pressure will be reduced, because the work point will move down.
Q: Notebook plug in the power adapter lights, but can not open the machine
This is a contradictory problem: First, the power adapter lights because the power is good, but does not mean that the computer is good; Second, can not open the machine with the power adapter is lit, it is your computer reasons. Recommendation: Check the computer hardware. Asked: But the battery can be used to start ah answer: Remove the battery plug in the adapter or put the battery installed plug in the adapter, if you can not open the machine, then it is a hardware conflict. The solution to the hardware conflict is that you try another adapter. Asked: the battery removed to die, but as long as there is a battery can answer: it shows that your adapter is bad. Asked: the more magical is plug in the adapter and the battery, the battery will not consume Answer: get you electronic city so that they give you a test. You can say to buy an adapter, and then try, you can use the words to buy, can not use the words and then think of other methods.
Q: Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
It should be the inverter problem, I have encountered before, followed by the inverter upgrade was resolved. Is to replace a set of power board, power board, CPU board.
Q: How to make the motor speed (control speed), can not use frequency
In general, the torque generated by the motor is reduced with decreasing frequency (decrease in speed), and the reduced actual data is given in some frequency converter manuals. By using the flux vector control of the inverter, will improve the motor at low speed torque, even in the low speed area motor can also output enough torque. When the frequency converter to speed up to 60Hz frequency, the motor output torque will reduce the normal motor is designed to 50Hz (60Hz) voltage, the rated torque is given in this voltage range. So the rated frequency under the speed is called constant torque speed, the inverter output frequency is greater than 50Hz frequency, the motor torque to be inversely proportional to the frequency of the relationship between the decline. When the motor is running at a frequency greater than 60 Hz, the magnitude of the motor load must be taken into account to prevent the motor output torque from being insufficient. For example, when the torque generated by the motor at 100 Hz is about to be reduced to about 50 Hz, the torque is generated. So the rated frequency above the speed is called constant power speed.
Q: Is the laptop power adapter hot?
Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.
Q: First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
And the inverter is connected to the positive and negative bk-dk electrical Han Han device,
Our products have obtained CE, FCC and RoHS and other certificates. With professional skills and technology, our monthly production capacity is 100,000 units. We have a strict quality control system to ensure that you receive qualified products. "Creativity and Sincerity" is our tenet. We sincerely hope to cooperate with customers from all over the world.

1. Manufacturer Overview

Location Shenzhen, Guangdong, China (Mainland)
Year Established 2012
Annual Output Value Below US$1 Million
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shenzhen
Export Percentage 91% - 100%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: Below 1,000 square meters
No. of Production Lines 4
Contract Manufacturing OEM Service Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords