• MV VFD AC Motor Drive 3KV 6KV 10KV System 1
  • MV VFD AC Motor Drive 3KV 6KV 10KV System 2
  • MV VFD AC Motor Drive 3KV 6KV 10KV System 3
MV VFD AC Motor Drive 3KV 6KV 10KV

MV VFD AC Motor Drive 3KV 6KV 10KV

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1PC pc
Supply Capability:
10,000pcs/year pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Specifications of MV VFD AC Motor Drive 3KV 6KV 10KV

 

Direct medium voltage input and output 

 

IGBT power units in series to obtain MV by means of overlap wave 

 

Up to 40% saving rate

 

Application Fields of MV VFD AC Motor Drive 3KV 6KV 10KV

  • Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump etc

  • Cement: draft fan, high-temperature fan, air blower, dust collection fan etc.

  • Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc.

  • Petroleum&Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc

  • Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc

  • Minerals & Mining: Mud pump, ventilation fan, slurry pump etc

     

Others: Loads such as fan, pump and compressor in pharmaceutical, paper making and wind tunnel test.

Especially for: Fan and Pump

 

Power Plant

Pump, Fans

Steel Plant

Fans

Cement Plant

Fans

 

   

Product Structure of MV VFD AC Motor Drive 3KV 6KV 10KV

AC Motor Drive Variable Frequency Drive consists of By-pass cabinet, Transformer cabinet, power unit cabinet and controller cabinet from left to right.

 

 

AC Motor Drive MV Variable Frequency Drive

 

 

Technical advantages of MV VFD AC Motor Drive 3KV 6KV 10KV

  • No need of extra output filtering device

  • Directly driving the general medium voltage synchronous or asynchronous motor and the temperature of the motor will not be increased.

  • No need of motor derating operation

  • No dv/dt damage to insulation of motor and cable

  • No torque ripple induced by harmonics, and the service life of motors and mechanism devices can be extended

  • No cable length limited when voltage drop is in the allowable range.

Besides the above advantages, AC Motor Drive MV Variable Frequency Drive has the following functions and features:

  • Protection of overload, overheat, over-current, open-phase, grounding, over-voltage, negative sequence.

  • Current limited function

  • Interlock protection of control power supply

  • Two sets of control power hot standby for redundancy

  • Power cell by-pass function

  • Control cabinet automatic bypass function

  • Cabinet door opening alarm function

  • Lock-phase function

  • Synchronizing switch function between variable frequency and power frequency (optional)

  • Soft start of motors, no impact to mechanical equipment and network

  • Voltage source High-high variable frequency drive, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.

  • High quality power input: By phase shifting of the secondary winding and multi-pulse diode rectifier, isolated powers can be acquired and supplied for power cells. (18 pulses for 3/3.3kV, 30/36 pulses for 6/6.6kV, 48/54 pulses for 10/11kV) By using the technique of multi-pulse rectifier, the harmonic current could be eliminated greatly.

  • Power cell communicate with controller through optic-fiber, completely electric isolated

  • Inner set PID regulator, can realize running in closed-loop

  • Multiple communication methods with host computer, isolated RS485 interface, standard MODBUS RTU, communication protocol, PROFIBUS DP (optional), industrial Ethernet communication protocol (optional)

  • Accurately fault records, can inquiry information and locate fault

  • Compact construction, reasonable layout (can do customer-design)

  • Very good protective design to dust, ferrum pulveratum, acid mist, moisture etc.

  • Bypass cabinethas a function of "five-protection", meanwhile, it has a pressure relief channel to ensure the safety of operators.

  • Modularized design of power units, interchangeable and easy to produce and repair.

Technical parameters of MV VFD AC Motor Drive

Series No

Parameters

Value

1

HVF Capacity(KVA)

250~8750kVA

2

Power of adaptive motor(KW)

200~7000KW

3

Input Frequency(Hz)

45~65Hz

4

Rated input voltage(kV)

3/3.3kV/4.16kV/6/6.6kV/10/11kV (+15%~ -35%)

5

THDi at power grid

<3% (Permissible value≤4%)

6

THDu at output side

<3% (Permissible value≤5%)

7

Input power factor

>0.95%(>20% of rated load)

8

Efficiency

>97%(under a rated load)

9

Output frequency(Hz)

0.5~120Hz

10

Output frequency resolution

0.01Hz

11

Rated output current(A)

36~600A

12

Overload capability

120%(1min), 150%(3s), 200%(Immediate protection)

13

Control mode

V/F control or Vector control

14

Logical control I/O signal

16 channels respectively

15

Analog input

0~10V/4~20mA

16

Analog output

0~10V/4~20mA Optional (2 channels)

17

Boolean input/output

Communications/Default point (expandable)

18

Acc & Dec time (S)

0.1~3000s

19

Communication with host

CAN, Profibus, Modbus, RS232, RS485 etc

20

Cooling mode

Forced air cooling

21

Storage temperature

00C~450C

22

Ambient temperature

-350C~+450C

23

Ambient humidity

95%, no condensation

24

Protection grade

IP40

25

Noise

<70DB

 

Q: 4 pole 380V 4-5.5KW frequency conversion motor and inverter about how much money, such as the use of electromagnetic speed motor comparison
4-5.5KW inverter made about 1300 or so, the frequency conversion motor about 3000 The same power of the electromagnetic governor + motor about 4000, the price is almost
Q: Can different brands of laptop power adapters be generic?
1, strictly speaking, different brands of laptop power adapter is not common. Even if the logo on the voltage and current are the same should not be mixed, will cause the power interface or motherboard failure or even damage. 2, with the same brand of different models of the power can be used temporarily, but should not be used for too long. 3, the cottage power adapter is best not to buy the use of hidden dangers, including spontaneous combustion and explosion, try to use the original power adapter.
Q: Inverter alarm a043, how is it
When there is a signal failure, if necessary, use DTI Board, if necessary, change P215 In addition, for the synchronous motor (P095 = 12): the inverter is released until the motor is at rest
Q: My Lenovo v450 laptop power adapter should be bad how to match?
Lenovo V450 laptop power adapter is broken, the warranty period is not artificially damaged can be directly to the Lenovo aftermarket replacement adapter can be outside the warranty period to pay maintenance, it is recommended to use the original power adapter the best. Laptop charger (Laptop Charger), that is, laptop charger. The traditional notebook charger can only output a single voltage to a type of notebook computer charging, the industry called the traditional notebook power adapter for the single band notebook charger (mainly in order to distinguish between the universal notebook charger.)
Q: The relationship between the power supply of the notebook and the battery
The relationship between the laptop power adapter and the battery should not be called a power supply relationship, both of which are devices that power the notebook host. The basic relationship between the power adapter, the battery, and the host is as follows:
Q: Laptop power adapter bad what is the phenomenon?
Either the power is bad or the machine on the power supply module is bad to repair service
Q: HP laptop power adapter how to open
Adapter is broken is difficult to repair, for a barThe common method is to insert the blade into the gap in the middle of the adapter and then pry open
Q: How to choose a power adapter
Your notebook power part of the compatibility is very good, in a certain voltage range of power can be used long, but still please note on the notebook subject.
Q: Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
Here is not the inverter can solve the problem, you should first 220V single-phase AC rectifier for the DC (full-wave rectifier plus filter about 310 volts),
Q: 400w 6-pole motor should be equipped with much of the inverter?
0.75KW just fine, neither waste the inverter resources, but also to meet the occasional overload. And 0.75KW inverter is the standard model.
As the leader in the field of medium Voltage Variable Frequency Drive, we have been focusing on providing the integrated solutions of automatic control and energy-saving technology etc. for customers, and its skill levels and market impact of medium voltage VFD are in the world-leading positions. We have provided products and services across more than twenty countries in six continents around the world, taking up the first market share (China) in the past nine years.

1. Manufacturer Overview

Location Beijing,China
Year Established 1998
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port TIANJIN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches