General Of MV Voltage 3KV 6KV 10KV Frequency Inverter
CNBM high Voltage Variable Frequency Drives are designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Application Filed Of MV Voltage 3KV 6KV 10KV Frequency Inverter
CMAX- series of medium voltage VFD can usually be applied in these fields:
Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .
Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill
Cement: fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.
Oil & Gas: water injection pump, oil transfer pumps, air compressor.
Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.
Water: water supply pump, circulating pump.
Technology Data Of MV Voltage 3KV 6KV 10KV Frequency Inverter
3KV series VFD
Model | A03/050~ A03/100
| A03/100~ A03/175
| A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40℃ | ||||
Storage/transport temperature | -40~70℃ | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 3900×2480×1200
| 4900×2480×1200 6000×2580×1200
| 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
6KV series VFD
Model | A06/050
| A06/050~ A06/080
| A06/080~ A06/100
| A06/100~ A06/170
| A06/170~ A06/220
| A06/220~ A06/400
| A06/400~ A06/610
|
Capacity(kVA) | ≤500 | 500~800 | 800~1000 | 1000~1750 | 1750~2250 | 2250~4000 | 4000~6250 |
Rated output current (A) | ≤50 | 50~80 | 80~100 | 100~170 | 170~220 | 220~400 | 400~610 |
Motor power (kW) | ≤400 | 400~630 | 630~800 | 800~1400 | 1400~1800 | 1800~3250 | 3250~5000 |
Input frequency | 45Hz~55Hz | ||||||
Rated input voltage | 6000V±10% | ||||||
Power factor | 0.95(>20%load) | ||||||
Efficiency | 0.96with rated load | ||||||
Output frequency | 0.5Hz~120Hz | ||||||
Frequency resolution | 0.01Hz | ||||||
Overload capacity | 120% 1 min, 150% immediately | ||||||
Analogue input | 0~10V/4~20mA | ||||||
Analogue output | 0~10V/4~20mA | ||||||
Acceleration/deceleration time | 0.1~3000s | ||||||
Digital input/output | expanded according to requirement | ||||||
Ambience temperature | 0~40℃ | ||||||
Storage/transport temperature | -40~70℃ | ||||||
Cooling | air cooling | ||||||
Ambience humidity | <90%,without condensation | ||||||
Altitude | <1000m | ||||||
IP class | IP20 | ||||||
Size(mm)(W×H×D) | 3600×2480×1200 | 3900×2480×1200 | 4200×2480×1200 5100×2480×1200
| 5200×2580×1200 | 6600×2580×1300 8700×2780×1400
| ||
Weight (kg) | 3500~4000 | 4000~5000 | 5000~6000 | 6000~8000 | 8000~14000 |
10KV series VFD
Model | A10/080 | A10/080~ A10/150
| A10/150~ A10/210
| A10/210~ A10/400
|
Capacity(kVA) | ≤1250 | 1250~2500 | 2500~3500 | 3500~6250 |
Rated output current (A) | ≤80Rated output current (A) | 80~150 | 150~210 | 210~400 |
Motor power(kW) | ≤1000 | 1000~2000 | 2000~2800 | 2800~5000 |
Input frequency | 45Hz~55Hz | |||
Rated input voltage | 10000V±10% | |||
Power factor | 0.95(>20%load) | |||
Efficiency | 0.96with rated load | |||
Output frequency | 0.5Hz~120Hz | |||
Frequency resolution | 0.01Hz | |||
Overload capacity | 120% 1 min, 150% immediately | |||
Analogue input | 0~10V/4~20mA | |||
Analogue output | 0~10V/4~20mA | |||
Acceleration/deceleration time | 0.1~3000s | |||
Digital input/output | expanded according to requirement | |||
Ambience temperature | 0~40℃ | |||
Storage/transport temperature | -40~70℃ | |||
Cooling | air cooling | |||
Ambience humidity | <90%,without condensation | |||
Altitude | <1000m | |||
IP class | IP20 | |||
Size(mm)(W×H×D) | 4500×2480×1200 | 5700×2480×1200 | 6800×2580×1300 | 10600×2580×1300 |
Weight(kg) | 3500~6000 | 6000~8000 | 8000~15000 | 15000~19000 |
- Q: My Lenovo v450 laptop power adapter should be bad how to match?
- Hello, this is not recommended to go online to buy. The original is too expensive, generally with the domestic voltage instability may occur, so I suggest you go to the computer city to buy. Generally good quality, to about 120. The The As for the model, you can look at the output power, or you take your bad adapter to go, people see a look. The The The You can use a few years no problem, power adapter this kind of thing, online to buy the replacement is not convenient. The Hope to help you
- Q: What is the application of variable frequency speed control?
- Generally used in the need for continuous speed control of the place. With the general exchange of motor than its advantages is able to continuously speed. DC motor, although also continuous speed control, but the price is expensive, the volume weight is too large.
- Q: I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
- Second, the use of low-speed inverter motor. Ordinary motor running for a long time, heat is certainly not work.
- Q: How does the variable frequency motor output torque at very low frequencies?
- 50hz the following frequency, u constant, current and frequency is proportional to the frequency down the output current is also down, and torque and current is proportional to the natural torque is small
- Q: Laptop power supply 20V 3.5A can use 20V 4.5A power adapter Mody, what impact?
- It's ok. As long as the voltage is appropriate on the line. Current value refers to the maximum current that can be output. How much depends on your computer. Or, with a big no harm, can only be better, if you can use a small, but a little longer charging time.
- Q: Do you want to pay attention to the number of poles of the motor when selecting the inverter?
- Inverter is generally selected by the power, do not consider the number of poles, but the inverter output current is controlled by the module, so you can choose in the selection as much as possible in accordance with the rated current to select the inverter. And left redundant party B overload and other phenomena.
- Q: There is no inverter comes with simple PLC programming function
- Inverters are generally digital input, and analog input, a digital output, etc., can also be controlled by means of communication. Digital input can be used as a positive and negative and reset the alarm, the analog input can be given as a speed, and how to use the inverter to see the specific model. Take the Siemens inverter, MicroMaster420,567 terminal 3 digital input, 8 for the 24V, 9 for the 0V, you can usually open the point on the 8th 24V back to 567, as a digital input, you can also directly into the switching power supply Of the 24V, but the switch power supply 0V and 9 terminals connected to the potential, or the inverter may not be able to identify the outside world 24V. (DP communication, USS communication, etc.), with the terminal input on the P0700 = 1, the user can set the command source, the panel can be input, 2, P0701 to P0703 corresponding to the three digital functions: parameters set to 1 forward, 2 for the reverse ... ... a lot of features and control methods, see the corresponding product manual like
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- Frequency converter in the 5-50Hz is constant torque frequency, 50-100Hz is constant power frequency, to see what you want to get the effect
- Q: The laptop's power adapter is too hot to do
- Installed adapter heat should be no problem, I am now under the books, the fan mouth is very hot, the weather may be more and more hot it
- Q: Computer frequency changer to do cd frequency changer how points positive and negative
- . In this circuit, the total capacitance is 6500 microfarads, the voltage is doubled.
1. Manufacturer Overview
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
MV Voltage 3KV 6KV 10KV Frequency Inverter
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000 per year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords