General Of MV Voltage 3KV 6KV 10KV Frequency Inverter
CNBM high Voltage Variable Frequency Drives are designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Application Filed Of MV Voltage 3KV 6KV 10KV Frequency Inverter
CMAX- series of medium voltage VFD can usually be applied in these fields:
Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .
Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill
Cement: fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.
Oil & Gas: water injection pump, oil transfer pumps, air compressor.
Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.
Water: water supply pump, circulating pump.
Technology Data Of MV Voltage 3KV 6KV 10KV Frequency Inverter
3KV series VFD
Model | A03/050~ A03/100
| A03/100~ A03/175
| A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40℃ | ||||
Storage/transport temperature | -40~70℃ | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 3900×2480×1200
| 4900×2480×1200 6000×2580×1200
| 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
6KV series VFD
Model | A06/050
| A06/050~ A06/080
| A06/080~ A06/100
| A06/100~ A06/170
| A06/170~ A06/220
| A06/220~ A06/400
| A06/400~ A06/610
|
Capacity(kVA) | ≤500 | 500~800 | 800~1000 | 1000~1750 | 1750~2250 | 2250~4000 | 4000~6250 |
Rated output current (A) | ≤50 | 50~80 | 80~100 | 100~170 | 170~220 | 220~400 | 400~610 |
Motor power (kW) | ≤400 | 400~630 | 630~800 | 800~1400 | 1400~1800 | 1800~3250 | 3250~5000 |
Input frequency | 45Hz~55Hz | ||||||
Rated input voltage | 6000V±10% | ||||||
Power factor | 0.95(>20%load) | ||||||
Efficiency | 0.96with rated load | ||||||
Output frequency | 0.5Hz~120Hz | ||||||
Frequency resolution | 0.01Hz | ||||||
Overload capacity | 120% 1 min, 150% immediately | ||||||
Analogue input | 0~10V/4~20mA | ||||||
Analogue output | 0~10V/4~20mA | ||||||
Acceleration/deceleration time | 0.1~3000s | ||||||
Digital input/output | expanded according to requirement | ||||||
Ambience temperature | 0~40℃ | ||||||
Storage/transport temperature | -40~70℃ | ||||||
Cooling | air cooling | ||||||
Ambience humidity | <90%,without condensation | ||||||
Altitude | <1000m | ||||||
IP class | IP20 | ||||||
Size(mm)(W×H×D) | 3600×2480×1200 | 3900×2480×1200 | 4200×2480×1200 5100×2480×1200
| 5200×2580×1200 | 6600×2580×1300 8700×2780×1400
| ||
Weight (kg) | 3500~4000 | 4000~5000 | 5000~6000 | 6000~8000 | 8000~14000 |
10KV series VFD
Model | A10/080 | A10/080~ A10/150
| A10/150~ A10/210
| A10/210~ A10/400
|
Capacity(kVA) | ≤1250 | 1250~2500 | 2500~3500 | 3500~6250 |
Rated output current (A) | ≤80Rated output current (A) | 80~150 | 150~210 | 210~400 |
Motor power(kW) | ≤1000 | 1000~2000 | 2000~2800 | 2800~5000 |
Input frequency | 45Hz~55Hz | |||
Rated input voltage | 10000V±10% | |||
Power factor | 0.95(>20%load) | |||
Efficiency | 0.96with rated load | |||
Output frequency | 0.5Hz~120Hz | |||
Frequency resolution | 0.01Hz | |||
Overload capacity | 120% 1 min, 150% immediately | |||
Analogue input | 0~10V/4~20mA | |||
Analogue output | 0~10V/4~20mA | |||
Acceleration/deceleration time | 0.1~3000s | |||
Digital input/output | expanded according to requirement | |||
Ambience temperature | 0~40℃ | |||
Storage/transport temperature | -40~70℃ | |||
Cooling | air cooling | |||
Ambience humidity | <90%,without condensation | |||
Altitude | <1000m | |||
IP class | IP20 | |||
Size(mm)(W×H×D) | 4500×2480×1200 | 5700×2480×1200 | 6800×2580×1300 | 10600×2580×1300 |
Weight(kg) | 3500~6000 | 6000~8000 | 8000~15000 | 15000~19000 |
- Q:400w 6-pole motor should be equipped with much of the inverter?
- 400w 6-pole motor with frequency converter, as long as 1kw inverter can be a.
- Q:Laptop power adapter leakage
- You feel, or do not feel is to take the amount of pen? If the feeling after it, then for a, if the amount of pen, then hand touched, it should not be bright. That is a induction, is Virtual electricity, it does not matter.
- Q:How does the spindle drive system of the inverter realize the positive and negative control of the main pole?
- The general inverter has an external terminal control and communication control two modes optional, select one of them can be completed ah
- Q:Motor a speed, the inverter will burn what is going on, the inverter is a large yuan
- Note that the quality of the inverter is not ye, and now this situation is already very rare, it is recommended to replace the inverter brand, you can use Bosch Rexroth, the British Witten, Huichuan, Senlan, Haili Pu, Ou Rui, etc. Branded.
- Q:Why G120 inverter to be equipped with 4-pole motor?
- On the upstairs that the motor parameters to be set on the possible, such as voltage, current, power, power factor, rated efficiency, rated frequency, rated speed, motor overload factor
- Q:If it is 8-pole variable frequency motor, enter the motor nameplate parameters in the inverter input for the 4 pole can?
- Motor brand above all, the general number of wrong is the inverter shows the speed is not right, for the speed control requirements are not high places will not be a problem, you can use
- Q:A water supply project, how to choose electrodes and frequency converters, such as giving a 7-storey water supply
- 4. Set by pressure (0.3-0.4Mpa). Control the inverter can be.
- Q:Does the inverter set the number of poles to match the number of poles of the motor?
- The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.
- Q:Is the number of Amps of the notebook power adapter higher than the original number of security on the computer?
- The current amperage of the power adapter is only experienced at its maximum output power, as long as the power adapter output voltage and your original no problem. For example, when the home circuit from the power supply into the terminal does not limit the size of the current, but to provide a fixed voltage. The more your household appliances, the greater the current through the power supply into your home. And the indoor air break switch is a current limit, this is based on the ability to accept the wire. From the point of view of the meter, you use the power equal to UIt = W, where UI is the voltage and current, two multiplication is equal to power, power multiplied by time equal to power consumption. Say back to your power adapter, the power adapter output voltage is rated, as long as this notebook with your original output voltage is the same as your notebook will not hurt. And the power adapter current is the maximum output, the consciousness is the power adapter output maximum power P will not exceed this value, usually 65W or 90W. Greater than the power of such a computer can not be stable operation. Or a physical point of view, the use of notebook power adapter, in fact, the internal is a number of parallel circuits, secondary knowledge tells us the voltage of the parallel circuit at any end are the same size, and parallel devices, the greater the total current in the circuit The
- Q:The parameters of the inverter is 4, 6 motor can be used
- Inverter parameters are 4, 6 motor can be used. Parameters can be changed, the general inverter has a special number of motor parameters set, as well as the motor speed settings, if the series can not be changed, put the speed out of the necessary amplification of the inverter to enlarge some.
1. Manufacturer Overview |
|
---|---|
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
MV Voltage 3KV 6KV 10KV Frequency Inverter
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000 per year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords