super products single core flexible rubber cable
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
super products single core flexible rubber cable
Advantage
factory directly provide
fast delivery
Specifications
Long-term allowable working temperature does not exceed 65 ℃
300 / 500V и ниже кабель погружного электродвигателя с водонепроницаемым резиновой оболочке для подключения погружного электродвигателя к сети переменного тока напряжения 300 / 500В и ниже, конец которого в воду, Длительно допустимая рабочая температура не превышает 65 ℃
JHS 6кВ кабель погружного электродвигателя с водонепроницаемым резиновой оболочке для передачи погружных насосов канализации напряжения 6кВ, Длительно допустимая рабочая температура не превышает 85 ℃
Applications
Waterproof rubber cables?apply?for transmission of the submersible motor with?AC voltage 500V and below. suitable for submersible pumps , mining, underwater , underwater landscape lights and other water treatment equipment.
3×2.5 3×2.5+1×1.5 1×4 3×4 3×4+1×2.5 1×6 3×6 3×6+1×4 1×10 3×10 3×10+1×6 1×16 3×16 3×16+1×6 1×25 3×25 3×25+1×6 1×35 3×35 3×35+1×6 1×50 - - 1×70
|
|
Workshop
Package & Shipping
- Q: Basically bought a new graphics card (480 gtx) and im going to install into my computer but i wish to also install a phyx card as well. This seems simple enought but i only have 2 6pin power cables in my pc atm and im am unsure how to install another 2 6pins. Current PSU is a antec 1000w
- You okorder /
- Q: What is the difference between VV22 and VV62?
- Cross-linked power cable heating the main reason there are . the choice of continuous allowable current is less than the load of the maximum continuous current power cable; . the power cable in the implementation of the cable for cold contact, the use of crimping pliers die too large, leading to copper . the air switch input and output and cable copper nose connection, the choice of non-standard flat gasket or no spring gasket; . the air switch input and output side of the cable and cable core crimp is not solid and reliable; When the cable is connected to a strand, the air switch bolts are not tightened. . high-power UPS running, the filter cabinet is not put, n harmonic effects of cable overload, neutral overload, serious lead to cable breakdown, and a fire hazard. . the power cable along the building facade iron cabinet box laying, the surrounding environment is not ventilated, poor heat dissipation. Select the power cable should consider the following factors: . the rated voltage of the cable is greater than or equal to the rated power supply system power supply system; . the cable can continue to allow the current to be equal to or greater than the maximum load current load; . Power supply system short-circuit stability requirements; . according to the length of the cable to determine whether the voltage drop to meet the requirements; . the end of the line minimum short-circuit current should be able to protect the device reliable action. . a high degree of breakdown strength; . low dielectric loss; . a very high insulation resistance; . excellent resistance to discharge performance; . with a certain degree of flexibility and mechanical strength; . long-term stability of insulation.
- Q: What I really just want to know is the equation and basic concept on how to determine the optimal length of power cable needed to connect two poles while knowing only the linear density of the cable.It does not matter how much sag is produced because of limitations due to the strength of the power cable.
- you could connect computers via direct cable get right of entry to on parallel port. you additionally can use a bypass cable for this u could desire to remeber a rule for create a bypass cable it incredibly is 1326 ability connect a million cable with third of different and a pair of with 6 th cable of different. have relaxing
- Q: This type of cable with the armor without expert advice, thank you. More
- Is there a problem driver in Device Manager? Should be driven by the problem
- Q: So I had this monitor I used to use, then didn't use it for a while, now I want to use it again but can't find the power supply cable. I can get a new one, but the thing is I have to know what to ask for, right? I don't know what cable to ask for. I did some google search on it too but still can't seem to find exactly the type of the cable that is specified. Help? Can someone do it for me so I can go to my local electronics score and look for a cable that will do the work?
- yeah man, that 3 prong cable is synonomous with pc's, i used a old imac cable for the longest time because it looks rad.
- Q: Hi All, i have a star sound 1200w 4way amp which i want to use just for my sub for the meanwhile as im waiting on a monoblock, please tell me if i can install the amp without the fuse that connects straight on the power cable?? and what is the main reasons for that fuse? thanks in advance
- Could you install it without a fuse. Yes. Should you install it without a fuse. No. If your power wire ever got shorted out it would melt and catch of fire. Their have been cars that burned to the ground because they did not have fuses.
- Q: i bought a new graphics card a while ago, an nvidia 9400gt (i now realize how LOL that is). i connected it, but i noticed there were no extra power cables hanging around that would fit on the small six pin slot on top of the card. the performance increase has basically been negligible, and i don't really want to mess with the power box. should i take it into a computer shop, or is there an easier solution?yes, i installed it correctly and everything. i'm 100% sure.
- You okorder /
- Q: which cables cant be near each other??(will cause noise radiation if put together)i gotta run some wires through my car and i dont know wich ones to keep away from others. im runnin...4 gauge (eventually will be 2 gauge) power wire for amp2 speaker wires for rear deck speakersrca cables for ampremote turn on wire for amp
- It does not seem likely that you will have a substantial problem with noise from speaker cables going through power cables and then the amp. Besides sheilding, use of capacitors on the power cable at the amp end (follow correct polarity on electrolytic types) will kill noise. A properly-rated, and connected, Zener diode is another step. Such things as antenna-leads are so sensitive that they are always well-shielded. ______________________________________... As for zener diode use, I have never heard of them being used in this application. But then, many new ideas have never been applied before. Sparky has pestered me with not one, but *two* hostile emails and is in some state of jealous frustration. He can't seem to figure how one could supress overvoltage transients using a zener (duh). If he had asked respectfully, I would have told him what I was thinking, but since he is determined to be a jerk about it, then whatever...
- Q: I recently bought a 750watt power inverter and there are two small cables to connect to it that look like small jumper cables. Can i connect my regular (longer/bigger) jumper cables to the car battery and connect the other end to the inverter cables??Ive been told that this will blow the inverter, and i've been told otherwise. Please let me know if you've had any experience doing this.Thanks,
- You'll be fine as long as you don't cross the cables- red to positive, black to negative. If you cross them you'll blow a fuse, or the inverter... Oh, and don't let the cables touch, they'll short out
- Q: types of computer cables and where they are being used?
- For communication between devices in the computer, such as the hard drive and the motherboard, either IDE or SATA cables are used. For power, Its either a 3 or 4-pin power connector, though some things have two pins (like fan connections to the mother board). Also, the SATA devices use SATA power cables.
Send your message to us
super products single core flexible rubber cable
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches