Submersible sewage centrifugal water pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
◊APPLICATION
Applied to pumping such liquid which is not clean, with solid matter or frictional matter, low viscous, lcorrosive, crystallizable, chemically neutral and close to water. Such as:
1. domestic wastewater treatment system
2. School,hospital,community wastewater treatment system
3. Irrigation
◊ Features
1. 100% copper wire
2. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision
3. Double sides mechanical seal graphite&ceramic
4. Demagnetization of stainless steel nuts
5. Anti-rust treatment castings and electrophoresis
6. New testing equipment
◊ OPERATION CONDITION
1.Maximum depth below water: 5m
2.Maximum trans medium temperature up to: 40
3.PH of trans medium is scope from 4-10
◊TECHNICAL DATA
description material | |
motor housing | stainless steel |
pump body | cast iron |
impeller | cast iron |
shaft | AISI420(2GR13) |
stator | DR510 steel |
winding | 100%copper |
seal | mechanical seal graphite&ceramic |
- Q: How to adjust the flow of piston pump?
- Changing the size of the current in the solenoid valve can change the angle of the tilting element, and then change the stroke length of the plunger in the pump cylinder, that is to say, to change the flow of the pump. An inclined angle is called a quantitative pump, and the angle of inclination can be changed, which is called a variable pump.
- Q: Working principle and diagram of axial piston pump with pressure compensation variable
- Adjust the flow characteristics, the first limit screw to the top, according to the flow and pressure changes in the required range, adjusting the spring set, the initial flow pressure began to change to meet the requirements, then the limit screw to the ultimate pressure when the flow is no longer changed, the relationship between flow and pressure the changes are determined by the pump itself.
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- 1) oil rotary vane vacuum pump is too low, no effect on the oil seal exhaust valve, rotary plug to refuel after large exhaust sound, and oil mist, that the level is too low, the gas can be eliminated.(2) the vacuum caused by the condensable steam pollution of oil should be changed, and new vacuum pump oil should be replaced.
- Q: The water tank of the fish tank does not air out and only has the water outlet
- The picture above is very clear, but I didn't say anything about it. My problem is solved. The intake pipe and the exhaust pipe are connected by the inverted T type. The intake pipe is upward, but not fixed. It can be rotated. The intake pipe can be rotated to adjust the number of bubbles
- Q: What does "anti pump" mean in pump operation?
- The working process of the main oil cylinder pushing back and forth against the pump when the S valve (C valve or valve or gate valve skirt) reverse swing, so the piston suction concrete cylinder is in the ash conveying pipe is exactly opposite is the pump suction pump (hopper is concrete and push into the hopper, the desizing)
- Q: Operating procedures for measuring pumps
- start-up1. Adjust the stroke indication to zero by adjusting the nut or handle with the rotary stroke.2 open the outlet valve.3. Open the inlet valve, pump, exhaust from the high point, exhaust from the relief valve, the breather valve.4, point motor, check the operation of the pump.5. Start the motor.6, without pressure on the premise, every 15 minutes to improve the stroke 20%, if there is no pressure, do not substantially improve the stroke.Note: (1) whether the sound or vibration of the pump is abnormal (2), whether the stroke adjustment is automatic or not
- Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
- Q: Hydraulic pump displacement refers to the pump shaft what?
- Just as you carry a spoon to the water. How much water can you pump at once (every turn)? That's the displacement.
- Q: How many square cables does the submersible pump for 7.5KW need?
- I=P/ (1.732Ucos phi) =7.5/ (1.732X0.38X0.85) =13A (calculated according to three-phase city power, power factor 0.85).
- Q: How accurate is the metering pump?
- In addition, when the oil supply is too large or the pipeline pressure rises unexpectedly, the volume of the liquid in the hydraulic chamber can be changed, thereby affecting the stability of the flow and reducing the metering accuracy of the pump. In order to solve the problem of how to stabilize the measurement accuracy of metering pump metering pump flow, how stable, the three valve device. The so-called actual refers to the combination of three functions including compensation, discharge and safety protection device or device supporting the hydraulic chamber, according to its action principle is different, is divided into automatic compensation and forced compensation two three valve device.
Send your message to us
Submersible sewage centrifugal water pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords