Submersible sewage centrifugal water pumpS
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
◊APPLICATION
Applied to pumping such liquid which is not clean, with solid matter or frictional matter, low viscous, lcorrosive, crystallizable, chemically neutral and close to water. Such as:
1. domestic wastewater treatment system
2. School,hospital,community wastewater treatment system
3. Irrigation
◊ Features
1. 100% copper wire
2. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision
3. Double sides mechanical seal graphite&ceramic
4. Demagnetization of stainless steel nuts
5. Anti-rust treatment castings and electrophoresis
6. New testing equipment
◊ OPERATION CONDITION
1.Maximum depth below water: 5m
2.Maximum trans medium temperature up to: 40
3.PH of trans medium is scope from 4-10
◊TECHNICAL DATA
description material | |
motor housing | stainless steel |
pump body | cast iron |
impeller | cast iron |
shaft | AISI420(2GR13) |
stator | DR510 steel |
winding | 100%copper |
seal | mechanical seal graphite&ceramic |
- Q: How to adjust the flow of piston pump?
- For the swashplate valve controlled by the solenoid valve, the swashplate is in an angle with the cylinder body, so the plunger is reciprocating in the pump cylinder when the cylinder rotates. It goes from 0 degrees to 180 degrees, that is, to the upper plunger position, the plunger cylinder volume gradually increased
- Q: What does the pump mortar do?
- 1: 2 cement mortar or cement mortar with the same proportion of other components except coarse aggregate in the concrete, the pump piston and the inner wall of the pipeline are fully lubricated, and a layer of lubricating film is formed
- Q: Concrete pump 125 pipe wall thickness
- Concrete pump, also called concrete pump, consists of pump body and pipe. The utility model relates to a machine for continuously conveying concrete along a pipeline by utilizing pressure, which is mainly used for building, bridges and tunnels
- Q: What are the basic technical parameters of the pump?
- Two, pump head H head is the unit weight of the liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid. Habits referred to as meters. Three, the pump speed is n RPM pump unit time revolutions, represented by the symbol n, the unit is r/min. four, the pump NPSH NPSH NPSH is also called net positive suction head, said main parameters of cavitation performance. Cavitation has been used a h power of five, the power of the pump. And the efficiency of the pump is usually refers to the input power, which is the prime mover on the pump shaft power, it is also known as the shaft power, denoted by P;
- Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
- Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
- Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
- Q: Is vane pump good or gear pump good?
- The main parts of a gear pump are gears that mesh with each other. The meshing driving gear and the driven gear are respectively arranged on two parallel rotating shafts. Because the gear teeth enter and exit the meshes, the volume of the teeth is changed, and the suction and discharge effect is formed.
- Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
- Working pressure - the actual working pressure of the motor, that is, the pressure of the input oil. The difference between the motor inlet pressure and the outlet pressure should be calculated.Rated (nominal) pressure under normal working conditions, according to the test standards for continuous operation of the maximum pressure, that is, the rated pressure, more than the maximum pressure is called overloading.
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
- Q: What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
- A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.
Send your message to us
Submersible sewage centrifugal water pumpS
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords