Centrifugal Submersible Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Centrifugal Submersible Pump for Sewage Water
1.Structure of WQ Series Centrifugal Submersible Pump Description
WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.
2.Main Features of the WQ Series Centrifugal Submersible Pump
• Compact structure, good appearance, low construction
•Operation stably, same inlet and outlet
•Convenient installation and maintenance
•Parallel connection and have many models to be chosen for difference flow rate and head
•Horizontally and vertically installation as different pipeline system
3.WQ Series Centrifugal Submersible Pump images
4.WQ Series Centrifugal Submersible Pump Specification
Model | Capacity | Head | Speed | Efficiency | Power | Outlet |
Q(m3/h) | H (m) | n(rpm) | η (%) | Kw | mm | |
40WQ-12-15-1.5 | 12 | 15 | 2900 | 48% | 1.5 | 40 |
50WQ-10-10-0.75 | 10 | 10 | 2900 | 54% | 0.75 | 50 |
50WQ-15-15-1.5 | 15 | 15 | 2900 | 51% | 1.5 | 50 |
50WQ-15-20-2.2 | 15 | 20 | 2900 | 51% | 2.2 | 50 |
50WQ-17-25-3 | 17 | 25 | 2900 | 53% | 3 | 50 |
50WQ-20-7-0.75 | 20 | 7 | 2900 | 62% | 0.75 | 50 |
50WQ-22-20-4 | 22 | 20 | 2900 | 69% | 4 | 50 |
50WQ-25-10-1.5 | 25 | 10 | 2900 | 67% | 1.5 | 50 |
50WQ-25-32-5.5 | 25 | 32 | 2900 | 49% | 5.5 | 50 |
50WQ-40-15-4 | 40 | 15 | 2900 | 76% | 4 | 50 |
50WQ-40-30-7.5 | 40 | 30 | 2900 | 62% | 7.5 | 50 |
65WQ-25-15-2.2 | 25 | 15 | 2900 | 52% | 2.2 | 65 |
65WQ-25-28-4 | 25 | 28 | 2900 | 58% | 4 | 65 |
65WQ-37-13-3 | 37 | 13 | 2900 | 60% | 3 | 65 |
80WQ-29-9-2.2 | 29 | 9 | 2900 | 48% | 2.2 | 80 |
80WQ-40-7-2.2 | 40 | 7 | 2900 | 50% | 2.2 | 80 |
80WQ-40-15-4 | 40 | 15 | 2900 | 57% | 4 | 80 |
80WQ-43-13-3 | 43 | 13 | 2900 | 65% | 3 | 80 |
80WQ-50-10-3 | 50 | 10 | 2900 | 72% | 3 | 80 |
80WQ-50-25-7.5 | 50 | 25 | 2900 | 56% | 7.5 | 80 |
100WQ-50-22-7.5 | 50 | 22 | 1450 | 63% | 7.5 | 100 |
100WQ-50-35-11 | 50 | 35 | 1450 | 62% | 11 | 100 |
100WQ-65-15-5.5 | 65 | 15 | 1450 | 59% | 5.5 | 100 |
100WQ-70-7-3 | 70 | 7 | 1450 | 75% | 3 | 100 |
100WQ-70-22-11 | 70 | 22 | 1450 | 70% | 11 | 100 |
100WQ-80-9-4 | 80 | 9 | 1450 | 62% | 4 | 100 |
100WQ-80-20-7.5 | 80 | 20 | 1450 | 71% | 7.5 | 100 |
100WQ-100-7-4 | 100 | 7 | 1450 | 75% | 4 | 100 |
100WQ-100-15-7.5 | 100 | 15 | 1450 | 70% | 7.5 | 100 |
100WQ-100-22-15 | 100 | 22 | 1450 | 61% | 15 | 100 |
100WQ-110-10-5.5 | 110 | 10 | 1450 | 67% | 5.5 | 100 |
100WQ-110-15-7.5 | 110 | 15 | 1450 | 75% | 7.5 | 100 |
150WQ-130-30-22 | 130 | 30 | 1450 | 69% | 22 | 150 |
150WQ-140-7-5.5 | 140 | 7 | 1450 | 79% | 5.5 | 150 |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
- Q: How about the depreciation of vacuum pumps?
- (three) appliances, tools, furniture and so on related to the production and operation activities, for 5 years;(four) aircraft, trains, ships and other means of transport for 4 years;
- Q: What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q: What is double hydraulic pump?
- Two hydraulic pumps installed on one shaft can be connected to increase output flow, and can also be connected to increase output pressure. See how the demand is. The system can change the mode of application at any time.
- Q: What are the application areas of pumps?
- Water pump has different uses, different transmission liquid medium, different flow, lift range, therefore, its structure form is not the same, the material is also different, summed up, can be roughly divided into:
- Q: Operating procedures for measuring pumps
- start-up1. Adjust the stroke indication to zero by adjusting the nut or handle with the rotary stroke.2 open the outlet valve.3. Open the inlet valve, pump, exhaust from the high point, exhaust from the relief valve, the breather valve.4, point motor, check the operation of the pump.5. Start the motor.6, without pressure on the premise, every 15 minutes to improve the stroke 20%, if there is no pressure, do not substantially improve the stroke.Note: (1) whether the sound or vibration of the pump is abnormal (2), whether the stroke adjustment is automatic or not
- Q: What is a positive displacement pump? He Weizheng displacement?
- The principle and structure of displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow
- Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
- Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
- Pigment pressure is less than 0.4mpa,About 0.3. Go up.As the pump diaphragm is in the middle of a connecting rod, equivalent to the cylinder cavity, the pressure will be reduced; and because of the loss of pigment tube pressure will be reduced.
- Q: What is the difference between centrifugal pump and self suction pump? Which is better?
- In order to prevent the filling liquid into the pump shell because of gravity flow in the low groove, in the pump suction pipe at the entrance of a non-return valve (valve); if the location of the pump below the liquid level in the tank, then start without irrigation pump.Self-priming pump is a self-priming centrifugal pump, centrifugal pump is a kind of.Specific choice of a pump, depending on your specific parameters and conditions of use.
Send your message to us
Centrifugal Submersible Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords