Centrifugal Submersible Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Centrifugal Submersible Pump for Sewage Water
1.Structure of WQ Series Centrifugal Submersible Pump Description
WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.
2.Main Features of the WQ Series Centrifugal Submersible Pump
• Compact structure, good appearance, low construction
•Operation stably, same inlet and outlet
•Convenient installation and maintenance
•Parallel connection and have many models to be chosen for difference flow rate and head
•Horizontally and vertically installation as different pipeline system
3.WQ Series Centrifugal Submersible Pump images
4.WQ Series Centrifugal Submersible Pump Specification
Model | Capacity | Head | Speed | Efficiency | Power | Outlet |
Q(m3/h) | H (m) | n(rpm) | η (%) | Kw | mm | |
40WQ-12-15-1.5 | 12 | 15 | 2900 | 48% | 1.5 | 40 |
50WQ-10-10-0.75 | 10 | 10 | 2900 | 54% | 0.75 | 50 |
50WQ-15-15-1.5 | 15 | 15 | 2900 | 51% | 1.5 | 50 |
50WQ-15-20-2.2 | 15 | 20 | 2900 | 51% | 2.2 | 50 |
50WQ-17-25-3 | 17 | 25 | 2900 | 53% | 3 | 50 |
50WQ-20-7-0.75 | 20 | 7 | 2900 | 62% | 0.75 | 50 |
50WQ-22-20-4 | 22 | 20 | 2900 | 69% | 4 | 50 |
50WQ-25-10-1.5 | 25 | 10 | 2900 | 67% | 1.5 | 50 |
50WQ-25-32-5.5 | 25 | 32 | 2900 | 49% | 5.5 | 50 |
50WQ-40-15-4 | 40 | 15 | 2900 | 76% | 4 | 50 |
50WQ-40-30-7.5 | 40 | 30 | 2900 | 62% | 7.5 | 50 |
65WQ-25-15-2.2 | 25 | 15 | 2900 | 52% | 2.2 | 65 |
65WQ-25-28-4 | 25 | 28 | 2900 | 58% | 4 | 65 |
65WQ-37-13-3 | 37 | 13 | 2900 | 60% | 3 | 65 |
80WQ-29-9-2.2 | 29 | 9 | 2900 | 48% | 2.2 | 80 |
80WQ-40-7-2.2 | 40 | 7 | 2900 | 50% | 2.2 | 80 |
80WQ-40-15-4 | 40 | 15 | 2900 | 57% | 4 | 80 |
80WQ-43-13-3 | 43 | 13 | 2900 | 65% | 3 | 80 |
80WQ-50-10-3 | 50 | 10 | 2900 | 72% | 3 | 80 |
80WQ-50-25-7.5 | 50 | 25 | 2900 | 56% | 7.5 | 80 |
100WQ-50-22-7.5 | 50 | 22 | 1450 | 63% | 7.5 | 100 |
100WQ-50-35-11 | 50 | 35 | 1450 | 62% | 11 | 100 |
100WQ-65-15-5.5 | 65 | 15 | 1450 | 59% | 5.5 | 100 |
100WQ-70-7-3 | 70 | 7 | 1450 | 75% | 3 | 100 |
100WQ-70-22-11 | 70 | 22 | 1450 | 70% | 11 | 100 |
100WQ-80-9-4 | 80 | 9 | 1450 | 62% | 4 | 100 |
100WQ-80-20-7.5 | 80 | 20 | 1450 | 71% | 7.5 | 100 |
100WQ-100-7-4 | 100 | 7 | 1450 | 75% | 4 | 100 |
100WQ-100-15-7.5 | 100 | 15 | 1450 | 70% | 7.5 | 100 |
100WQ-100-22-15 | 100 | 22 | 1450 | 61% | 15 | 100 |
100WQ-110-10-5.5 | 110 | 10 | 1450 | 67% | 5.5 | 100 |
100WQ-110-15-7.5 | 110 | 15 | 1450 | 75% | 7.5 | 100 |
150WQ-130-30-22 | 130 | 30 | 1450 | 69% | 22 | 150 |
150WQ-140-7-5.5 | 140 | 7 | 1450 | 79% | 5.5 | 150 |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- (1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
- Q: The water tank of the fish tank does not air out and only has the water outlet
- The picture above is very clear, but I didn't say anything about it. My problem is solved. The intake pipe and the exhaust pipe are connected by the inverted T type. The intake pipe is upward, but not fixed. It can be rotated. The intake pipe can be rotated to adjust the number of bubbles
- Q: What's the difference between non negative pressure and variable frequency water pump?
- When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
- Q: What is the pump delivery? What's the difference between years and years?
- Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
- Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
- The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
- Q: What are the parts of a pump? How do you classify it?I just want to know
- The liquid ring pump: pumping air, the working medium is generally at room temperature water gas lift pump: simple structure of submersible sewage pump: a form of basic principle, performance parameters of centrifugal pump, with it the same. Underwater installation, sound, water cooling condition, screw pump: spiral lower invasion water medium variety formThere are too many kinds of pumps, such as submersible pumps for wells, centrifugal feed pumps, sewage pumps, etc. the submersible pumps are wet, oil immersed, etc.The water pump for automobiles is divided into oil lubrication and grease lubrication,
- Q: Hydraulic pump displacement refers to the pump shaft what?
- Just as you carry a spoon to the water. How much water can you pump at once (every turn)? That's the displacement.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.
- Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
- The centrifugal pump at a fixed speed, the head is fixed, adjust the outlet valve to adjust the diversion area
Send your message to us
Centrifugal Submersible Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords