Centrifugal Submersible Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Centrifugal Submersible Pump for Sewage Water
1.Structure of WQ Series Centrifugal Submersible Pump Description
WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.
2.Main Features of the WQ Series Centrifugal Submersible Pump
• Compact structure, good appearance, low construction
•Operation stably, same inlet and outlet
•Convenient installation and maintenance
•Parallel connection and have many models to be chosen for difference flow rate and head
•Horizontally and vertically installation as different pipeline system
3.WQ Series Centrifugal Submersible Pump images
4.WQ Series Centrifugal Submersible Pump Specification
Model | Capacity | Head | Speed | Efficiency | Power | Outlet |
Q(m3/h) | H (m) | n(rpm) | η (%) | Kw | mm | |
40WQ-12-15-1.5 | 12 | 15 | 2900 | 48% | 1.5 | 40 |
50WQ-10-10-0.75 | 10 | 10 | 2900 | 54% | 0.75 | 50 |
50WQ-15-15-1.5 | 15 | 15 | 2900 | 51% | 1.5 | 50 |
50WQ-15-20-2.2 | 15 | 20 | 2900 | 51% | 2.2 | 50 |
50WQ-17-25-3 | 17 | 25 | 2900 | 53% | 3 | 50 |
50WQ-20-7-0.75 | 20 | 7 | 2900 | 62% | 0.75 | 50 |
50WQ-22-20-4 | 22 | 20 | 2900 | 69% | 4 | 50 |
50WQ-25-10-1.5 | 25 | 10 | 2900 | 67% | 1.5 | 50 |
50WQ-25-32-5.5 | 25 | 32 | 2900 | 49% | 5.5 | 50 |
50WQ-40-15-4 | 40 | 15 | 2900 | 76% | 4 | 50 |
50WQ-40-30-7.5 | 40 | 30 | 2900 | 62% | 7.5 | 50 |
65WQ-25-15-2.2 | 25 | 15 | 2900 | 52% | 2.2 | 65 |
65WQ-25-28-4 | 25 | 28 | 2900 | 58% | 4 | 65 |
65WQ-37-13-3 | 37 | 13 | 2900 | 60% | 3 | 65 |
80WQ-29-9-2.2 | 29 | 9 | 2900 | 48% | 2.2 | 80 |
80WQ-40-7-2.2 | 40 | 7 | 2900 | 50% | 2.2 | 80 |
80WQ-40-15-4 | 40 | 15 | 2900 | 57% | 4 | 80 |
80WQ-43-13-3 | 43 | 13 | 2900 | 65% | 3 | 80 |
80WQ-50-10-3 | 50 | 10 | 2900 | 72% | 3 | 80 |
80WQ-50-25-7.5 | 50 | 25 | 2900 | 56% | 7.5 | 80 |
100WQ-50-22-7.5 | 50 | 22 | 1450 | 63% | 7.5 | 100 |
100WQ-50-35-11 | 50 | 35 | 1450 | 62% | 11 | 100 |
100WQ-65-15-5.5 | 65 | 15 | 1450 | 59% | 5.5 | 100 |
100WQ-70-7-3 | 70 | 7 | 1450 | 75% | 3 | 100 |
100WQ-70-22-11 | 70 | 22 | 1450 | 70% | 11 | 100 |
100WQ-80-9-4 | 80 | 9 | 1450 | 62% | 4 | 100 |
100WQ-80-20-7.5 | 80 | 20 | 1450 | 71% | 7.5 | 100 |
100WQ-100-7-4 | 100 | 7 | 1450 | 75% | 4 | 100 |
100WQ-100-15-7.5 | 100 | 15 | 1450 | 70% | 7.5 | 100 |
100WQ-100-22-15 | 100 | 22 | 1450 | 61% | 15 | 100 |
100WQ-110-10-5.5 | 110 | 10 | 1450 | 67% | 5.5 | 100 |
100WQ-110-15-7.5 | 110 | 15 | 1450 | 75% | 7.5 | 100 |
150WQ-130-30-22 | 130 | 30 | 1450 | 69% | 22 | 150 |
150WQ-140-7-5.5 | 140 | 7 | 1450 | 79% | 5.5 | 150 |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
- Q: Must the water pump in the tank be all soaked in water?
- Need a submersible pump in the water, but it is not entirely like this, I have to work for a long time no problem in water, but there is a problem you should pay attention to the water pump, at least in half, or stop when the smoke is not on water.
- Q: What is the minimum continuous flow of a pump?
- At'-- the allowable temperature rise of pumping medium,C- pumping medium specific heat, kj/ (kg DEG C);Ho- off dead center lift, M.Minimum continuous flow minimum continuous stable flow and minimum continuous thermal flow and the maximum value in the selection, or use the pump process, the minimum continuous flow process requirements must be greater than the minimum flow rate of the pump, otherwise it will cause the pump cavitation, vibration and noise, so that the pump parts damaged. If the minimum continuous flow the pump can not meet the minimum requirement's process, can install the bypass reflux device or reflux system in the pump pipeline, to ensure that the minimum continuous flow pump.
- Q: What are the causes of pump shock?
- 3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output
- Q: What's the pump? Where can I use it?
- Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.
- Q: Advantages and disadvantages of centrifugal pumps?
- The uniform liquid no pulse phenomenon.(2) shortcomingsBefore running, the pump must be filled with liquid.For the supply of small flow, large pressure head inappropriate, inefficient and limited.Encountered imperfect design or operation is not at the time, such as milk, it is easy to produce foam, affecting the next process production.The installation is wrong. There will be "Qi tie" phenomenon.The efficiency is also lower than the reciprocating pump.The sources of knowledge are absolutely reliable!!!!
- Q: How many kilograms of water pump are there in the automatic washing machine on the market?
- Suitable for supporting high pressure sprayer, portable car washer. Water pump with overflow circuit. And comes with pressure switch, overflow switch double insurance
- Q: What is the pump delivery? What's the difference between years and years?
- 1) integer integer: ~ batch. Sell ~.2) buy in bulk: ~ goods. Sell now.The exchange is, according to the duration of the contract delivery insurance premium, payment is generally in common, 5 years of insurance you every year that time, continuous call five years; general single sex 5 years or even 10 years of premium.Furthermore, the insurance premium is good or good pay period, if a single rate from the point of view, to make cheaper than single period, but considering the one-time payment of the interest cost of funds and the opportunity cost, there is no difference. While the single cross ratio advantage is mainly reflected in its flexibility. First of all, additional premium may be added to the premium. At present, additional risks can only be covered if the main risks and principal risks are covered during the payment period. The single way to buy insurance, even in the primary insurance protection period will no longer be able to purchase additional insurance new; secondly, to pay the premium can enjoy a premium waiver. If the insured in full payment period has not yet had the danger, not pay part of the premium would be exempt from the Qing dynasty. For child insurance, the premium waiver is more advantageous. If parents unfortunate accidents or illness, resulting in death or one or two, three disabled or suffering from severe illness, the insurance company will be exempted after the premium, the insurance contract shall continue to be valid; finally, to pay the premium or additional premium amount can be changed. The policy holder may adjust his insurance plan according to the change in his economic strength. In contrast, single premium has the advantage of a one-time payment more convenient.
- Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
- The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Send your message to us
Centrifugal Submersible Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords