• steel wire ropes for lifts System 1
steel wire ropes for lifts

steel wire ropes for lifts

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
20000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Steel Grade:carbon constructional quality steel

  • Standard:AISI, ASTM, BS, DIN, GB, JIS

  • Wire Gauge:3.05mm

  • Place of Origin:Zhejiang, China (Mainland)

  • Type:Galvanized

  • Application:Manufacturing

  • Alloy Or Not:Non-alloy

  • Special Use:Free Cutting Steel

  • Model Number:3.05mm

  • Tensile strength:≥1380Mpa

  • 1% elongation:≥1170Mpa

  • Zinc coating:≥275

  • Tolearance:-0.08 +0.1

  • Elongation L=250MM:≥4.0%

  • Joint:No Joint

  • C%:0.50-0.85%

Packaging & Delivery

Packaging Details:Z2 , Coil . Plastic Roll, or wooden reel as the dimension of the reel is according to your requirement
Delivery Detail:Within 15 days after confirmation

Specifications

3.05mm high carbon galvanized steel wire
1.Good quality
2..Professional manufacturer
3.Prompt delivery

3.05mm high carbon galvanized steel wire    

1.Diameter range:0.8-5mm

2.Main application:making spring,mattress,for ACSR,for fence.for optical fibre,for hose

3.Standard: ASTM B498 ASTM B500

4.Type:low carbon,middle carbon,high carbon

5.Z2 packing ,ply-wood reel, Roll packing etc.,or as your requirements

Q: Three parallel wires are each carrying a 4A current. ; wire A) is 6 mm from wire B) which is 3mm from wire C); The current in wires B and C are out of the paper, while A is into the paper. What is the magnitude and direction of the magnetic field halfway between wires A and B?I have tried using Biot-Savart Law but keep getting it wrong can someone please help? I also have an equation for two parallel wires but how do I relate it to two?
You can use the Biot-Savart Law, but it is confusing and kind of a waste of your time and space. For straight wires, someone ALREADY worked out the Biot-Savart Law. See the following link for the result: hyperphysics.phy-astr.gsu.edu/Hba... The formula of interest for us is B = mu0*I/(2*Pi*r) where mu0 is magnetic permeability of free space, I is current, and r is distance from the wire carrying the current. B is the magnetic field due to that PARTICULAR wire. To deal with three wires, use a superposition principle and stack magnetic fields on top of each other. Do be aware of direction: remember the right hand rule. RH rule for magnetic fields in vicinity of wires: point thumb in direction of current, curl fingers to show the magnetic field circulation direction. Use this sign convention: + B is up along page, -B is down along page For Wire A: point of interest is r = d_ab/2 or 0.003 m to the right of wire A Point thumb in to the paper and the finger curl indicates that B_A is downward B_A = -mu0*I_A/(pi*d_ab) For Wire B: point of interest is r = d_ab/2 or 0.003 m to the left of wire B Point thumb out of the paper and the finger curl indicates that B_B is downward B_B = -mu0*I_B/(pi*d_ab) For wire C: point of interest is r = d_ab/2 + d_bc or 0.006 m to the left of wire C Point thumb out of the paper and the finger curl indicates that B_C is downward B_C = -mu0*I_C/(2*pi*(d_ab/2 + d_bc)) Add up: Bnet = B_A + B_B + B_C Bnet = -mu0*I_A/(pi*d_ab) - mu0*I_B/(pi*d_ab) - mu0*I_C/(2*pi*(d_ab/2 + d_bc)) Simplify: Bnet = -mu0/pi*(I_A/d_ab + I_B/d_ab + I_C/(d_ab + 2*d_bc)) data: mu0:=4*Pi*10^(-7) Tesla-m/A; I_A:=4 A; I_B:=4 A; I_C:=4 A; d_ab:=0.006 m;d_bc:=0.003 m; Result: Bnet = -6.667 milliTeslas negative sign indicates downward direction.
Q: So earlier my passenger low beam wouldn't turn on. i went and bought a circuit tester and found out a wire located here _-_ lt;=== (the bottom right plug on the socket) that wire wont light up. i bought a socket at the same time, but i dont know how to replace it. and even if i did.. i don't see how that would fix the wire.It's possible the wire is fine. but i cleaned the socket and all that and still nothing.any advice would be great. i really need to drive at night1994 GMC jimmy
The wire that leads to your socket may be worn or damaged. Find out which wire is not working. Use a meter that has a sharp probe, so you can stab the wire with the probe and see if it is putting out the electricity, up the wire from where you put the socket on. If the wire is not working, but off the part of the wire that is not working and splice in a new piece of wire and attach to the socket. Hopefully this will help you.
Q: I dont' know if quot;a wiremeans phone call, or whatever the original sentene from the story is as follows:quot;Because I had a wire from Hilton Cubittthis morning.quot;
That's from the day of telegraph messages; it was the urgent medium.
Q: How much does it cost to install telephone wires in your household?Does it cost around $200.00 ?
in NYC (718) verizon charges close to 200.... the carrier i work for charges much less.. and when I do freelance work I get about 1/4 that.... you can hire anyone you want to install the telephone wiring inside your home, you do not need to pay your telephone company so much to install a jack... if you are talking about getting new phone service... in NY verizon charges 125....
Q: two straight and parallel wires are separated by 6 cm. there is a 2 A current flowing in the first wire. if the magnetic field strength is found to be zero between the two wires at a distance of 2.2 cm from the first wire, what is the magnitude and direction of the current in the second wire?
If the magnetic field at 2.2cm is zero it means that at that distance the fields produced by the two wires cancel out. At 2.2cm from the first wire the field strength is B= uI/ 2pi r ... . where u is the permitivity of free space, 4.0 x 10^-7 N/A^2 B= (4.0 x 10^-7 N/A^2)( 2 A)/ 2(3.14)(0.022m) B=( 8 x10^-7)/(0.138) B= 5.79 x 10^-6 Tesla The magnitude of the magnetic field from the other wire must be equal in magnitude at 3.8cm away (6- 2.2) and opposite in direction. Using the right hand rule (thumb points in direction of current and fingers curl around the wire to show the direction of the magnetic field) you can see that for the magnetic fields to be in opposite direction between the two wires the current must be flowing in the same direction as the first wire. Using the formula for magnetic field strength you can then determine the current needed. 5.79 x10^-6 T= (4.0 x 10^-7) I/ 2 (3.14)(0.038m) THen solve for I I= (5.79 x 10^-6 T)(2)(3.14)(0.038m)/ 4.0 x 10^-7) I= 3.45 A Therefore there is a current of 3.45A in the wire and it is flowing in the same direction as the first.
Q: i have a 2002 pontiac sunfire where is my ground wire located? what does it look like?
Ground wire for what?
Q: i want to install a new light in a old house.the problem is that there are three black wires coming out of he ceilng.the old light fixture has two black wires. two ceiling wires are connected to one fixture wire and the other ceiling wire i connected to he other fixture wire.i dont know which is the hot wire and which is the comon wire.also the new light has a ground wire ,2 blue wires and 2 white wires but, there is no ground wire coming out of the box. please help
You'll need a multi-meter to test which wire is neutral and which is hot. Technically you don't need to use the ground wire (green), but it would be a good idea for safety to run one from the box to the nearest ground (copper cold water pipe or the fuse panel). Sounds like your fixture has two light sockets? If so, you probably connect the 2 blue wires to the hot wire and the two white to neutral.
Q: But I want to switch it and wire the red ceiling wire to the black fan wire and the black ceiling wire to the black/white fan wire so that the particular switches work the way I want them to. Is this ok, to switch them?
Black wire on the fan is for the fan motor, red wire in the fan is for the light, the white wire is the neutral wire. So if you do want to switch the light off and on you have to tie red wire to the switch and the black wire can be tied to the hot at the ceiling box so you can control the fan with the chain only. If you have one switch leg in your circuit then you cannot do anything but switch them both if you tie them together. I think I am understanding what you are saying here. White Alyse ties to white Black is for the fan motor and the red is for the light. If you have three wires in the switch then you can tie them the same way color to color. Hope this has not confused you You can email me if you need further help
Q: 1 green wire, 1 black with red stripe wire
Green wire = positive Black with red tracer = negative
Q: The spark plug wire on my dirt bike needs to be replaced because it was touching the exhaust and it burned through.I was wondering if the ignition coil and spark plug wire are one piece and need to both be replaced or is there someway to disconnect spark plug wire? They spark plug wire doesn't seem to be pluged in, but it seems to be one piece. Does anyone know?
if okorder

Send your message to us