Standard Hot DipGalvanized Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Commercial Galvanized Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: my speaker makes a fuzzy or static noise while the scene has high or low sound. I cut my wire in half because I bought a subwoofer and we didn't get the wires with it. So I cut it. After all I didn't need the wire for the subwoofer. Could my speakers make such noises because of cutting a wire?
- I have no idea what you did. Which speaker(s) makes a static noise? You cut your wire in half. Which wire? Is your subwoofer wired to the speaker outputs or the SUB OUT on the receiver? Did you splice this wire or simply trim it, strip the ends and plug it into the receiver speaker outputs and the terminals on a speaker? What are you powering these speakers and subwoofer with? A receiver or an all in one HTIB unit? The best way to get good answers with any question is to provide as many details as possible - model numbers and the conditions under which the problem occurs. Details please.
- Q: Wire diagram
- Hello there George, It has become common over the past few years that non-residential boilers are wired with EPO (emergency, power off) switches just outside each door to the boiler room. This is similar to having fire alarm pull boxes by the exits. I do not know of any jurisdiction that requires it for a residence. On occassion I've seen the 24 volt circuit for the thermostat being switched, which is a bit sketchy. Normally the 120 volt circuit for the controller is switched. The switches used are of the pushbutton type.
- Q: What method can be used to detect residual impurities and metal particles on the wire surface?
- Remove the metal surface oxide, refers to the removal of the metal itself has been oxidized surface, such as: rust, skin and other materials that originally belong to the material itself.
- Q: I have 2 wires coming up a conduit. i need to put those wires into a timer and then to my pump. can anyone explain or has a website with diagrams
- The timer is just like a light switch, The hot from the power source (black wire) goes to one side of the timer. From the other side of the time it takes a wire to go to the pump. The white (neutral) goes from the power source to the pump. Provided this is 120 volts.
- Q: The resistivity of a 18.0 m long wire is 3.76E-8 Ω.m and its cross sectional area is 6.52E-6 m2. If the wire carries a current of 1.44 A, what is the voltage across the wire?
- R = ( rho x l)/A Where: R is the resistance, rho the resistivity, l the length and A the area Resiatance of wire = (3.76 x 10^-8 x 18)/6.52 x 10^-6 R = 0.1038 Ohms Voltage across wire = current through wire x resistance of wire V = I x R V = 1.44 x 0.1038 V = 0.14947 V = 0.15 Volts
- Q: I need to use quot;insulated copper wireor quot;enamel covered copper wirefor a project...I used normal copper wire and obviously it failed. Can this be like normal copper wire with plastic/rubber coating around it, similar to electrical wire? Or is it something special?
- Insulated copper wire is just another term for electrical wire that has insulation on it. Yes, you use normal copper wire that is insulated with rubber, plastic or enamel. Enamelled wire is the stuff you see in motor windings, comparitively fine and coated with transparent enamel for insulation.
- Q: how do you connect two copper wires together
- You have your choice. Some choices depend on the use of the wire. You can solder them, join them with crimp connectors, use wire nuts, or use screw down terminals. If the wire are for electrical house wiring, wire nuts are requires. If for low voltage inside equipement or the like, any of the listed methods will work fine.
- Q: i already tried wiring this light, but it didn't work. I always thought black wire to black, white to white and ground to ground. i connected the light fixture black wire to the three black wires (as shown in image) and the light fixture white wire to the three white wires, and connected ground wires together.when i flipped on the breaker, the light came on with the switch on off and the breaker tripped. i'm assuming this is wrong and i provided an image as i see in my ceiling mount. Can somebody kindly direct me how to properly connect the light fixture to these wires. thanks!
- without seeing the ceiling fixture container and wiring myself, i may well be hesitant to propose you as to what the greater wires are for. I anticipate which you mean the sector on the ceiling has those wires in them, not the ceiling fixture which you obtain, on account that that could have had a wiring diagram that explains what the wires may well be for. If I had to guess, i might say that the sector contains 3 wires because of the undeniable fact that it is going to have had a ceiling fan that operated on a various substitute than the easy, or possibly the easy is additionally controlled from 2 particular switches on unique aspects of the room, or may well be the two one in each of those. Do you have gotten an AC voltage tester to verify which wires are sizzling (stay) and which at the instant are not? I hate to propose this, although by potential of and massive your great wager is to conform with the wires back to their source to look what they're for. Do you have gotten a faux ceiling you are able to open up? Do the wires pass into the attic or crawlspace the place you ought to look at them jointly as not having to tear open the gypsum board or plaster ceiling? you ought to easily positioned all the whites mutually and all the blacks mutually, and verify the grounds are in place, hoping they have a reason. although now not information what they're there for is a sturdy thank you to rationale an electric fire. and that i'm specific doing that could now not be authorized via your close by electric development codes.
- Q: I have a 2 wire system in my garage and need to update to a 3 wire grounded plug. Can I leave my existed 2 conductor and just run a single 12 gauge insulated ground in the same conduit back to the panel/grounding rod. Or do I need to pull out the 2 wore replace with 3 wire ?
- It will could be tough to pull if there are existing wires in there. You may need to tie a line to what you remove, then lube a new set of wires, and pull the new line and wire back through.
- Q: subs - dvc 4ohm 2 of them 600wattrms on each wiring it to a 1200 watt amp same brand as sub amp is 1 ohm stable to i wire the subs together and then to the amp a 1ohm? that would give each sub 600 watts right?
- The current passing through the wires will cause the wires to heat up if not sufficient guage. Think of the millions of little electrons pushing and shoving back and forth, all this action causes friction on a molecular level and of course we all know friction equals heat. In a bigger guage wire there is more room for the same number of electons. It's really that simple. Use as heavy a guage speaker wire that you can. You will have no signal loss and little heat.