• Stainless Steel Vertical Multistage Centrifugal Water Pump System 1
  • Stainless Steel Vertical Multistage Centrifugal Water Pump System 2
  • Stainless Steel Vertical Multistage Centrifugal Water Pump System 3
Stainless Steel Vertical Multistage Centrifugal Water Pump

Stainless Steel Vertical Multistage Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Performance of CDL Series Stainless Steel Vertical Multistage Pump

Flow Range:1-200m3/h

Head Range:11-200m

Power Range:0.37-110KW

Temperature:-20ºC-120ºC

Material:Stainless Steel 304,316

Work Pressure:<1.6mpa< span="">

2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor). 

3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber. 
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC 
Environmental temperature: highest + 40 ºC 
Height: highest 1000m 

4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors. 
Protection grade: IP55 
Insulation grade: F 
Standard voltage: 1Ph 220-230/240V 
3Ph 200-220/346-380V 
3Ph 220-240/380-415V 
3Ph 380-415V 

5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization. 
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system. 
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali. 
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator. 
Irrigation: farm irrigation, sprinkler, drip.

 

6. FAQ

1>  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.


Stainless Steel Vertical Multistage Centrifugal Water Pump

Stainless Steel Vertical Multistage Centrifugal Water Pump





Q:Does vacuum pump oil belong to dangerous goods?
Of flammable substances, but not included in dangerous goods!Does not belong to dangerous goods,
Q:Does the reservoir water heater press the booster pump (high marks)?
60 liters of water storage should be able to drive two bathrooms at the same time bath! Water storage water heater generally does not need booster pump, as long as there is a little pressure, the water heater is filled with water, as long as the tap water can do. You can turn off the hot water valve and see only the amount of water in the cold water. If hot water is much smaller than cold water, it is the reason for the heater. Can you check the water mixer is normal, the one-way valve is installed in reverse.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:There are second cutting, third cutting, why three times?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q:What are the reasons for sealing damage of centrifugal pumps?
Two, cavitation. Cavitation (mainly from a thermal centrifugal pump).Because the medium is hot water, the water temperature is too high to produce steam, the gas in the pipeline enters the pump cavity height, and the part of the gas can not be discharged, thus causing water shortage to run, the machine seal dry grinding is invalid, and the cavitation erosion device is not available.Process: replace the machine seal.
Q:Do you have a suction pump higher than 9 meters?
Since the atmospheric pressure has been basically determined, the theoretical suction degree of the pump is more than 10 meters.
Q:What is the liquid pump? What are their categories? What are their strengths and weaknesses?
The air driven liquid pump adopts compressed air driving method, and has the following advantages:The pressure can be adjusted by manual pressure control valve or air control valveIt is driven by air and is especially suitable for explosion protection applicationsAble to achieve pre-set final pressureAutomatic pressure relief by pumpLong term conservation without consuming energyWhen holding pressure, medium will not overheatThe utility model has the advantages of convenient installation and low maintenance cost, and only needs to connect the gas source, the inlet pipeline and the pressure pipelineReliable operation, low maintenance cost and little noise at the time of operation
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Centrifugal pumps require a vacuum to produce negative pressure, which allows atmospheric pressure to lift the water surfaceAxial flow pump impeller is thrust on water
Q:I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
(8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:What are the general water pump failure, how to repair?
Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches