Those Fluorocarbon Coating Spiders have excellent weather ability and are best used in heavily polluted and coastle areas.
We are the professional manufacturer of producing point-fixed Glass Wall Fittings (Flat Cap Routel, Countersunk Routel, Splice Routel, Connector, Spider for the end Tension Rod, Spider for the Cable Net, Fin Spider, Glass Clamp, The Accessories of the Opening Window for the Point-fixed Glass Curtain Wall, The Strut Bar for the TensionCable, The Strut Bar for the Tension Rod, Tension Rod, Tension Cable etc.).
1 |
Product Name |
Stainless steel point-fixed Glass Wall Fittings |
2 |
Brand |
FITSHY |
5 |
Material |
201, 302, 304, 304L, 316, 316L, according to customers' requirements |
6 |
Standard |
GB, JIS, AISI, BS, DIN |
7 |
Size |
CC=150mm |
CC=160mm | ||
CC=200mm | ||
CC=210mm | ||
CC=220mm | ||
CC=250mm | ||
CC=300mm | ||
8 |
Finishing |
Mirror polished, Matte finish, Fluorocarbon coating(all kinds of colors) |
9 |
Usage |
Glass curtain wall and glass canopy |
10 |
Package |
Bubble bag + Inner box + Carton |
11 |
MOQ |
100 SETS |
12 |
Delivery time |
In stock |
13 |
Price |
0-10000 USD/set |
14 |
Service |
1.Product design drawings (CAD) |
2.Professional engineer advices | ||
3.Installation guiding | ||
4.Product Warranty is offered | ||
5.OEM, ODM , Customer design | ||
15 |
Payment |
L/C, T/T |
16 |
Ability |
30,000 sets |
The recommended value for the loading of single arm of spider
NO. |
Spider Series Code |
Material:304 | |
Permissible axial load (N) (negative pressure) |
Radial Allowable load (N) (dead weight) | ||
1 |
ST-150 Series “X” Shape |
1500 |
1000 |
2 |
ST-160 Series “X” Shape |
2000 |
1200 |
3 |
ST-200 Series “X” Shape |
3000 |
1500 |
4 |
ST-210 Series “X” Shape |
3000 |
2000 |
5 |
ST-220 Series “X” Shape |
3000 |
2000 |
6 |
ST-250 Series “X” Shape |
3500 |
2000 |
7 |
ST-300 Series “X” Shape |
4000 |
2000 |
- Q: Residential stone curtain wall design height of not more than 50m to demonstrate it
- In accordance with the provisions of Article 6, paragraph 1, of Annex II of the "more dangerous part of the project with a greater risk than that of the" more dangerous part of the project safety management approach ", only 50 meters and above Expert argument.
- Q: Curtain wall design documents review how qualified newspaper supervision
- You should say is the curtain wall of the drawings review certificate. Do not need any format, do not have a separate inspection, copy a copy of the supervision to the OK. The The And the original should be given to the Party
- Q: Department of Construction and Construction (2017) 38 on the construction of glass curtain wall what are the requirements
- Personnel-intensive, large-scale commercial center, transportation hub, public cultural and sports facilities and other places, near the road, square and the lower for the entrance, personnel access to the building, is strictly prohibited with the whole frame glass curtain wall. Above the building in the second floor and above the installation of glass curtain wall, should be in the surrounding area below the curtain wall reasonable set of green belt or podium and other buffer areas, can also be used to pick the canopy, anti-impact awning and other protective facilities.
- Q: Building energy efficiency acceptance of what documents
- Technical documents 1.1 through the review of the agency to review the energy-saving design and related technical documents (such as energy-saving design, energy-saving design calculations, etc.); 1.2 exterior wall, roof and hot bridge parts of the insulation construction practices or construction program design and construction plans; 2 Building and insulation materials for the manufacture of specimens 2.1 wall samples: If the ordinary clay hollow brick wall should be asked about 60 ordinary clay hollow brick, such as small hollow block (190 × 190 × 390) wall should obtain 14 blocks and seven small pieces of small hollow block ; Roof test specimen: 0.20 cubic meters of concrete material should be obtained; 2.2 sand: about 200 kg; 2.3, cementing material (cement 30 kg, lime cream 10 kg, etc.); 2.4 insulation materials and installation of insulation materials annex (calculated by 1.5 square meters); 2.5 plaster material and finishes (in 1.5 square meters).
- Q: What is the classification of building materials?
- Construction technology information according to its nature is divided into seven categories: The first category: construction project legal construction procedures necessary documents; Category II: Integrated management information; The third category: engineering quality control information; Including: acceptance of information Construction management information Product quality certification documents Inspection Report Construction record and inspection report The fourth category: engineering safety and functional inspection data and the main function of the record; The fifth category: inspection batch quality acceptance records; Category 6: Construction log; The seventh category: the completion of the map;
- Q: What are the contents of the curtain wall energy conservation project quality acceptance?
- Curtain wall energy-saving project quality acceptance includes the following: 1) hidden acceptance requirements. 2) curtain wall materials, accessories, accessories, components of the quality, including insulation materials, glass, shade components, unit curtain wall panels, seals, insulation profiles. 3) materials, accessories, accessories, components witnessed sampling, re-inspection requirements. 4) curtain wall air tightness requirements, laboratory inspection requirements. 5) curtain wall thermal construction requirements, including insulation material installation, steam layer, curtain wall and wall joints, structural joints, structural joints, hot bridge parts, heat sink joints, unit curtain wall between the joints, Water drainage structure and so on. 6) construction and installation requirements, including insulation material fixed, partition thermal bridge, steam layer, ventilation equipment, glass installation, shade installation, condensate drainage system installation.
- Q: How many calculations for a square meter of material?
- Curtain wall material calculation points: 1. Panel: panel ratio of expansion area * utilization (general 1.03) 2. keel: linear density * per square meter length * utilization (generally 1.05 ~ 1.15, according to material specifications) 3. Attachment: use per square meter (weight or volume number) * Utilization rate (general 1.03) 4. Low-value consumables: 15 ~ 25 (yuan / m2, according to the type of curtain wall to consider) 5. Labor costs: market decisions
- Q: Bidding documents are glass curtain wall, the party has to check the aluminum alloy window, how to do?
- Should be agreed by the contract, if the contract is not agreed, that is, according to the actual settlement of the two sides resolved.
- Q: Whether the civil tender contains the curtain wall and does not contain the curtain wall, behind the owner and the general contract of the contract agreement What is the difference
- If not included, that the curtain wall to a separate tender, not included in the total package management, that curtain wall bid to issue a separate bid notice, the top of the tender to do the chapter, curtain wall units and owners signed a contract, the record is to take both sides of the contract and curtain wall Successful notice of the record.
- Q: What are the curtain wall materials to do? The beginning of the time
- Other quality assurance information.
1. Manufacturer Overview
Location | Shanghai,China (Mainland) |
Year Established | 2012 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | Southeast Asia; Africa; Mid East; Eastern Asia; South Asia; Domestic Market |
Company Certifications | HACCP;ISO 9001:2000;ISO 9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 31% - 40% |
No.of Employees in Trade Department | 1-2 People |
Language Spoken: | |
b) Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered |
Product Price Range | Average |
Send your message to us
Stainless Steel Point-fixed Glass Wall Fittings Fluorocabon Coating Spiders/Glass Spider
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Sets set
- Supply Capability:
- 30000 Sets Per Month set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords