• QDX.QX Series Submersible Water Pumps System 1
QDX.QX Series Submersible Water Pumps

QDX.QX Series Submersible Water Pumps

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product introduction:
QDX. QX series submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller.Motor which is monophase or three phase is at the upper pa" of pump and seal is used where pump and motor combine, which is a kind of double end mechanical seal "O " rings are applied to all static joints. Floator switch can be equipped to control pump" starting and stopping automatically according to the water level.

Application:
This series pump is small and light, which is widely used in countryside for elevating water from well, irrigation, sprinkling and domestic water supply, and also used in draining off water for fishpond and building site.

Work Conditions:
The pump can work properly and continuouslyunder following operational conditions:
1 .Medium is not corrosive, Sand contents shouldbe max. 0.10% by volume and granular sizeshould be max.0.2mm.
2.Medium temperature shouldn’t be over 40℃ and PH should be6.5-8.5.
3.The pumps should be operated within rated head.
4.The pumps should be fully submerged into water with depth of less than 3m mad max. the pump should be min.0.5m over the water bottom and not be inserted into sludge.
5.Power frequency should be 50Hz, single phase voltage 220V, three-phase voltage 380V, and voltage fluctuation should be 0.9-1.1 times than the rated .


Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: What are the internal losses in centrifugal pumps? How did they come about?
Due to the friction of the bearing, the friction in the stuffing box, and the losses caused by the rotation of the impeller (the loss of the roulette wheel);
Q: What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".
Q: What are the application areas of pumps?
Water pump has different uses, different transmission liquid medium, different flow, lift range, therefore, its structure form is not the same, the material is also different, summed up, can be roughly divided into:
Q: What does "efficiency" mean in a water pump catalog?
The efficiency of the water pump nameplate refers to the maximum efficiency that the pump can reach at the rated speed
Q: What does centrifugal pump mean horizontally?
In other words, pump casing and pump body along the horizontal center of the pump leaves into the upper and lower halves, so that when the pump leaves the pump cover open, you can pump and bearings as a whole pumping out. No need to remove the pipe. I don't know. Do you understand?.
Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
Q: Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.
Q: What do you mean by the self coupling device on the pump?
Auto is an installation of the pump, which comprises a pedestal, self coupling frame, a guide rod and a guide rod support, the bottom fixed coupling frame, vertical installation of two guide rods can easily be brought down without installing the pump, the pump at the bottom of the pool, the outlet of the pump and the discharge tube can automatically lock, don't need to bolt connection, automatic coupling position, so as to achieve the effect of simple and convenient. When you need to repair, pump the pump up without jumping into the sink.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords