Product introduction:
QDX. QX series submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller.Motor which is monophase or three phase is at the upper pa" of pump and seal is used where pump and motor combine, which is a kind of double end mechanical seal "O " rings are applied to all static joints. Floator switch can be equipped to control pump" starting and stopping automatically according to the water level.

Application:
This series pump is small and light, which is widely used in countryside for elevating water from well, irrigation, sprinkling and domestic water supply, and also used in draining off water for fishpond and building site.

Work Conditions:
The pump can work properly and continuouslyunder following operational conditions:
1 .Medium is not corrosive, Sand contents shouldbe max. 0.10% by volume and granular sizeshould be max.0.2mm.
2.Medium temperature shouldn’t be over 40℃ and PH should be6.5-8.5.
3.The pumps should be operated within rated head.
4.The pumps should be fully submerged into water with depth of less than 3m mad max. the pump should be min.0.5m over the water bottom and not be inserted into sludge.
5.Power frequency should be 50Hz, single phase voltage 220V, three-phase voltage 380V, and voltage fluctuation should be 0.9-1.1 times than the rated .


Q: Piston filling and peristaltic pump filling which precision is high?
These two pumps are used as a metering pump to use, so the accuracy is to be on a par with the peristaltic pump has more advantages than the piston pump is the largest energy fluid conveying there are particles, and the piston pump is smaller than the peristaltic pump pulse, so we need to choose according to the material characteristics you need to transport.
Q: Why does the centrifugal pump close the pressure to start?
Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before opening, and the outlet valve is closed. However, the export valve closed time can not be too long, because at this time the medium in the pump cycle, the medium temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q: What is the lift of diaphragm pump?
Tell you: diaphragm pump head is liquid through the pump energy obtained is called lift it, and flow and pump speed, a liquid density is generally 1 kg is 10 meters lift, horizontal pipeline 10 meters 1 meters lift, a 90 degree bend is 1 meters.
Q: Advantages and disadvantages of centrifugal pumps?
Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
Q: What are the basic technical parameters of the pump?
Two, pump head H head is the unit weight of the liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid. Habits referred to as meters. Three, the pump speed is n RPM pump unit time revolutions, represented by the symbol n, the unit is r/min. four, the pump NPSH NPSH NPSH is also called net positive suction head, said main parameters of cavitation performance. Cavitation has been used a h power of five, the power of the pump. And the efficiency of the pump is usually refers to the input power, which is the prime mover on the pump shaft power, it is also known as the shaft power, denoted by P;
Q: Brief description of centrifugal pump on / off operation
Two, centrifugal pump start(1) the pump entrance valve fully open, start motor, outlet valve fully closed, fully check operation of pump.(2) when the pump outlet pressure is higher than the operation pressure, the outlet valve is gradually opened to control the flow and pressure of the pump.(3) check whether the motor current is within the rated value, such as the pump in the rated flow operation, and the motor overload should stop the pump inspection.
Q: How many concrete pump tube diameter
The pump is generally divided into 125 and 150 two, the inner diameter is 125mm and 150mm. And the two kinds of each have high and low pressure points. Low pressure type type 125 pump for the pipeline diameter is phi 133,
Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
The valve opening pump is aimed at the centrifugal pump.From the power curve of the centrifugal pump, the power of the centrifugal pump increases with the increase of the flow rate; the flow curve of the centrifugal pump shows that the flow rate of the centrifugal pump decreases with the increase of the head.
Q: What do you mean by the self coupling device on the pump?
Installation of GAK self coupling device:The installation of automatic coupling submersible sewage pump is mainly the installation of coupling device and the lifting of pump. In the pump before the installation of the rings on the chain, and the pump used for lifting.Installation procedure of coupling device:The coupling frame with four bolts fixed on the pump body; the water outlet pipe is fixed on the substrate; positioning cone mounted on the pipe seat; the lower end of the guide pipe is sleeved in the positioning cone, the upper end is sheathed on the guide rod of the rubber block; the guide rod frame is fixed on the pool wall. The function of the rubber block: the axial compression degree of the rubber block is adjusted by the screw on the guide rod frame, so that the diameter of the rubber block is consistent with the inner diameter of the guide rod, and the guide rod is stable.