Product introduction:
QDX. QX series submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller.Motor which is monophase or three phase is at the upper pa" of pump and seal is used where pump and motor combine, which is a kind of double end mechanical seal "O " rings are applied to all static joints. Floator switch can be equipped to control pump" starting and stopping automatically according to the water level.

Application:
This series pump is small and light, which is widely used in countryside for elevating water from well, irrigation, sprinkling and domestic water supply, and also used in draining off water for fishpond and building site.

Work Conditions:
The pump can work properly and continuouslyunder following operational conditions:
1 .Medium is not corrosive, Sand contents shouldbe max. 0.10% by volume and granular sizeshould be max.0.2mm.
2.Medium temperature shouldn’t be over 40℃ and PH should be6.5-8.5.
3.The pumps should be operated within rated head.
4.The pumps should be fully submerged into water with depth of less than 3m mad max. the pump should be min.0.5m over the water bottom and not be inserted into sludge.
5.Power frequency should be 50Hz, single phase voltage 220V, three-phase voltage 380V, and voltage fluctuation should be 0.9-1.1 times than the rated .


Q: Know flow and lift how to calculate the pump power?
P: the density of refrigerant, when the working fluid is water, P =1ETA - pump efficiency, can not find desirable value =0.8N=30x (200/3600) x9.81x1/0.8=20.44 = 20 (kW)(that is, 20kW motors)
Q: 5 floor water pressure is too low, what kind of water pump is better?
The location of the pump is too far away from the pumping pool, the suction of the pump is not enough, cavitation phenomenon, pumping water, this water pump manufacturers, the pump will be placed in a reasonable position
Q: What is double hydraulic pump?
[double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
Q: Water pump can not be pumped out, how to maintain water?
The pipe leaks or leaks:The nut may not pinch well when it is installed. If the leakage is not serious, it can be coated with cement or mixed with asphalt oil in the places where the gas leaks or leaks. Temporary repairs can be done with wet mud or soft soap. If the leakage at the joint, you can tighten the nut by hand. The leak is critical and must be re assembled.
Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
The unit of displacement is the milliliter. How many milliliters does the pump rotate per circle? The displacement is the pump, the individual,The unit of flow is generally a liter, a figure added to the displacement of the pump over a period of time,
Q: What are the parts of a pump? How do you classify it?I just want to know
According to the working principle can be divided into: centrifugal type and volume type centrifugal pump. By the centrifugal force of the impeller will accelerate the refrigerant, through to stay, so as to achieve the purpose of boosting; volume by changing the refrigerant in the flow volume to boost purpose.According to the media and installation conditions, water pump: centrifugal pump used: the impeller pump shaft, a curved blade on the impeller impeller outlet. The central entrance water vertically along the tangential direction of axial flow pump: high speed, large flow, low lift, mixed flow pump and centrifugal pump structure similar to that of the blade outlet angle is different, wide flow channel, close to the performance of axial flow pump displacement pump: safety valve must be opened before the start (metering pump, screw pump)
Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
Centrifugal pump, and is a very common method of centrifugal pump, flow with the head (or pressure) increases, off a small valve resistance increases, the pump head should be increased, then the flow decreased, whereas open valve flow increase
Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
Rated flow refers to the flow under the rated speed and rated pressure input to the motor.Due to leakage loss, the actual flow of the input motor must be greater than its theoretical flow. Actual flow of motor (i.e. inlet flow) leakage flow = theoretical flow of the motor.
Q: What does "dual purpose" of water pump mean? Please expert advice
2, the pump must pay attention to maintenance after use, for example, when the pump is used up, the water pump should be put clean, it is best to remove the water pipe, and then rinse with water.5, the water pump on the tape should be removed, and then rinse with water after drying in the light place, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.6, to carefully check whether there are cracks in the impeller, the impeller fixed to the bearing on whether there is loose, cracks and loose if the phenomenon to be timely maintenance, if the water pump impeller should also be above the earth clean.
Q: What's the submersible pump?What is a submersible pump, and what about it?
Not afraid of water, because it is placed in the water itself to cool themselves, you can use for a long time. The amount of water pumped and the height of the water now basically meets the needs of a small amount of individual and a large number of factories. This is the submersible pump, the water pump in the water. You can see.