Product introduction:
QD/Q series submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump,which is adopted centrifugal impeller.Motor which is monophase or triphase is at the upper part of pump and seal is used where pump and motor combine, which is a kind of double end mechanicalseal,"0" rings are applied to all static joints.
Application:
The motor pump is adopted multistage impellers, and has advantage of high head, which is widely used in countryside and industry for elevating water from well, irrigation, sprinkling and tower water supply, and also used in draining off water for building sites.
Work Conditions:
The pump can work properly and continuously under following op¬erational conditions:
1.Medium is not corrosive. Sand contents should be max.0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40℃ and PH should be
6.5-8.5.
3.The pump should be operated within rated head. The pump should be min.0.5m over the water bottom and not be inserted into sludge.
4.Power frequency should be 50Hz,single phase voltage 220V , three-phase voltage 380V,and voltage fluctuation should be 0.9-1.1 times than the rated.
- Q: Is the diaphragm pump and the drain pump one?
- Therefore, the need to play a liquid discharge pump, if the medium is corrosive liquid, high viscosity, volatile, flammable, highly toxic liquid, you can choose diaphragm pump. Conversely, the general liquid, there is no special requirements, you can use the general centrifugal pump to reduce costs.
- Q: What are the starting and stopping procedures for centrifugal pumps?
- Operation method and operation procedure of self-priming centrifugal pumpClick number: 440 release time: 2011-7-24Centrifugal pump method, centrifugal pump operation steps, centrifugal pump use steps
- Q: Advantages and disadvantages of centrifugal pumps?
- The centrifugal pump has no valve, so it is suitable for conveying suspended liquid, and the special design can also transport large solid suspensionThe pump can be made of chemical resistant material, which is suitable for conveying corrosive solution.The utility model has the advantages of simple structure, few parts, little failures, durability, low maintenance cost, convenient management and reliable work.The output can be adjusted even by the discharge valve fully closed, there is no danger of infinite rising pressure head.The liquid is transferred to a large quantity. And the pressure head does not require large, most suitable for centrifugal pump.
- Q: Why can the centrifugal pump hold down the pressure?
- The centrifugal pump can hold pressure because of the suction pipe in the pump at the entrance of a non-return valve (valve).
- Q: Does the reservoir water heater press the booster pump (high marks)?
- If insufficient pressure really, adding an automatic booster pump in the water inlet, is feasible. Home booster pump, a basic model, to sell the place to ask the next to know, generally 200 yuan or so, traffic 0.3-1.8, 90~150 watts on it. Do not buy too large, too much power, the water will also be too large, but the water heater will not be used.
- Q: Is the flow meter in front of the pump or after the pump?
- After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better
- Q: The working principle of magnetic pump
- Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
- Q: What does "dual purpose" of water pump mean? Please expert advice
- 2, the pump must pay attention to maintenance after use, for example, when the pump is used up, the water pump should be put clean, it is best to remove the water pipe, and then rinse with water.5, the water pump on the tape should be removed, and then rinse with water after drying in the light place, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.6, to carefully check whether there are cracks in the impeller, the impeller fixed to the bearing on whether there is loose, cracks and loose if the phenomenon to be timely maintenance, if the water pump impeller should also be above the earth clean.
- Q: Metering pumps related matters
- Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.
- Q: What is the difference between centrifugal pump and self suction pump? Which is better?
- If the centrifugal pump in full before the start of the shell of the gas, then start after the center of the impeller was thrown in the gas can not be large enough to form the vacuum, so that liquid in the bath can not be sucked, so the centrifugal pump to start before using foreign liquid in the pump housing space filling