QD Series Submersible Water Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product introduction:
QD/Q series submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump,which is adopted centrifugal impeller.Motor which is monophase or triphase is at the upper part of pump and seal is used where pump and motor combine, which is a kind of double end mechanicalseal,"0" rings are applied to all static joints.
Application:
The motor pump is adopted multistage impellers, and has advantage of high head, which is widely used in countryside and industry for elevating water from well, irrigation, sprinkling and tower water supply, and also used in draining off water for building sites.
Work Conditions:
The pump can work properly and continuously under following op¬erational conditions:
1.Medium is not corrosive. Sand contents should be max.0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40℃ and PH should be
6.5-8.5.
3.The pump should be operated within rated head. The pump should be min.0.5m over the water bottom and not be inserted into sludge.
4.Power frequency should be 50Hz,single phase voltage 220V , three-phase voltage 380V,and voltage fluctuation should be 0.9-1.1 times than the rated.
- Q: What are the meanings of the vacuum pump, the front pump and the main pump?
- The main pump and the front pump with the general vacuum unitThe front pump can be understood as a mechanical pump. It can be used by itself, but the pumping rate or the vacuum can not meet the requirements. In this case, we add a booster pump
- Q: What is a water pump coupling device?
- The automatic coupling device of the water pump coupling device has compact structure and small occupation area. The sump pump works because it is submergedThe utility model can be directly installed in a sewage pool, and no special pump house is needed to install a pump and a machine, thereby saving large amounts of land and infrastructure expenses
- Q: Working principle and diagram of axial piston pump with pressure compensation variable
- Working principleThe main part (see section structure) the transmission shaft drives the rotating cylinder, the plunger seven uniform distribution on the cylinder to rotate around the shaft center line through the center of the spring will be slippery boots column components in the variable pressure in the head (or swash plate). In this way, with the rotation of the plunger cylinder for reciprocating motion complete, oil absorption and oil pressure action.
- Q: Fire pump and shower pump flow head selection, high resolution.
- 2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
- Q: What does "anti pump" mean in pump operation?
- Function: anti pump effect when used for pumping concrete pumping occurs overpressure, the pumping pressure is above 25MPA, the concrete conveying pipe out of ash, can be understood as the precursor of pipe blockage, at this time should immediately use the anti pump, the concrete from the conveying pipe in the suction into the hopper, thus preventing plugging happen
- Q: What are the starting and stopping procedures for centrifugal pumps?
- Operation method and operation procedure of self-priming centrifugal pumpClick number: 440 release time: 2011-7-24Centrifugal pump method, centrifugal pump operation steps, centrifugal pump use steps
- Q: Operating procedures for measuring pumps
- start-up1. Adjust the stroke indication to zero by adjusting the nut or handle with the rotary stroke.2 open the outlet valve.3. Open the inlet valve, pump, exhaust from the high point, exhaust from the relief valve, the breather valve.4, point motor, check the operation of the pump.5. Start the motor.6, without pressure on the premise, every 15 minutes to improve the stroke 20%, if there is no pressure, do not substantially improve the stroke.Note: (1) whether the sound or vibration of the pump is abnormal (2), whether the stroke adjustment is automatic or not
- Q: What are the parts of a pump? How do you classify it?I just want to know
- According to the working principle can be divided into: centrifugal type and volume type centrifugal pump. By the centrifugal force of the impeller will accelerate the refrigerant, through to stay, so as to achieve the purpose of boosting; volume by changing the refrigerant in the flow volume to boost purpose.According to the media and installation conditions, water pump: centrifugal pump used: the impeller pump shaft, a curved blade on the impeller impeller outlet. The central entrance water vertically along the tangential direction of axial flow pump: high speed, large flow, low lift, mixed flow pump and centrifugal pump structure similar to that of the blade outlet angle is different, wide flow channel, close to the performance of axial flow pump displacement pump: safety valve must be opened before the start (metering pump, screw pump)
- Q: What is a vacuum pump for?
- In fact, the vacuum pump and high Swiss fan, high Swiss high-pressure blower, high Rui high-pressure pump principle is almost the same
Send your message to us
QD Series Submersible Water Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords