Plastic-insulated control cable Plastic-insulated control cable e
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
The products is manufactured according to the standards of GB9330 《polyvingyl chloride insulated control cable》,IEC60502《Extruded solid dielectric insulated power cables for rated voltages from 1kv to 30kv. We can also produce PVC insulated ,.XLPE insulated and 600/100v control cables according to other standard and customers’ request. Other serial products such as flame resistant, fire proof, screened , armored, rat and termite resistant and Environment-friendly halogen-free low smoke etc.
Type and usage of product in common use
Type | Designation | Main used in paticular situation |
KVV | Copper conductor PVC insulated PVC sheathed control cable | Installed indoor, in cable trench and conduit |
KVVP | Copper conductor PVC insulated PVC sheathed and braided-shield control cable | Installed indoor, in cable trench and conduit and certain place which needs screen |
KVVP2 | Copper conductor PVC insulated PVC sheathed and copper tape screening control cable | ditto |
KVV22 | Copper conductor PVC insulated PVC sheathed and steel tape control cable | Installed indoor, in cable trench and conduit and direct burried certain place which can stand heavy mechanism pressure |
KVV32 | Copper conductor PVC insulated PVC sheathed and steel wire control cable | Installed indoor, in cable trench and cable shaft and certain place which can stand heavy mechanism pressure |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed and copper tape screening steel tape armoured control cable | Installed indoor, conduit and direct buried and such certain place which needs screen and can stand heavy mechanism pressure |
KVVP22 | Copper conductor PVC insulated PVC sheathed and copper tape screening control cable | Installed indoor, conduit and direct buried and such certain place which needs screen and can stand heavy mechanism pressure |
KVVR | Copper conductor PVC insulated PVC sheathed flexible control cable | Installed indoor where needs remotion and soft place |
KVVRP | Copper conductor PVC insulated PVC sheathed and copper tape screening flexible control cable | Installed indoor where needs remotion,soft screening place |
Note: flame retardancy products’type begins with ZR, and fire-proof with NH TYPE Cross-sectional area mm2 0.5 0.75 1.0 1.5 2.5 4 6 10 NO. CORE KVV KVVP -------- 2-61 2-14 2-10 KVVP2 -------- 4-61 4-14 4-10 KVV22 KVVP2-22 -------- 7-61 4-61 4-14 4-10 KVV32 -------- 19-61 7-61 4-14 4-10 KVVR 4-61 ------ ------ KVVRP 4-61 4-48 ------ ------
NOTE: No. of cores adviced: 2、3、4、5、7、8、10、12、14、16、19、24、27、30、37、44、48、52和61
- Q: I'm building another computer to give to someone, i have all the parts and when it got down to installing the CD drive and the Hard drive i plugged the sata cables into the motherboard but when i looked to install them to the power supply mine did not have any of those cables. I had spare cables from my other power supply but they require you to plug them into the power supply but since the other power supply is older it doesn't work. I was wondering if i could get cables that plug into the extra connectors then to the CD drive/ Hard drive instead of plugging them into the power supply then the CD drive/ Hard drive.
- There's 2 types of power connectors, old style 4-pin Molex and Sata power. Adapters are pretty cheap, just check Monoprice.
- Q: keep in mind this is a 6 yr old machine, the old roms connected the old way, I don't even know the name of the old cables.....
- yah! you can buy a SATA power cable converter. but i don't think if there is a IDE cable to SATA cable converter? is your mother board have a SATA socket?
- Q: So I was trying to run wiring for a 220 outlet and I hit a lower leg with the metal cable snake, now a bunch of outlets loose power for a minute or two ever so often, 20 min give or take. What can be the cause? Only the top breaker tripped. How can this be repaired. Please help.
- You may have loosened a connection. With the breaker off, check all the outlets on the circuit that's losing power and make sure all the connections are tight.
- Q: How should connectors for storage device cables and connectors for power supply be described?
- well the storage device cables are called SCSI (Small Computers System Interface) and those power cables don have any special names,,, The power output from smps comprises of four wires.. +12v -12v +5v and -5v
- Q: ive recently opned my external harddrive case so that i could put dat harddrive in my pc ... i was able to take out the ide cable but i cnt take out the power cable... plz help me.. how can i take out the power cable?
- Thats nothing new..Molex connectors often stick do not try to pull it out by the wires! grab it by the sides of the connector and wiggle it back and forth (side to side) it will come out eventually!
- Q: When I plug in my xbox that wire with the box on it has a red light instead of a green and ocassionally it turns yellow and my xbox wont turn on how do I fix this
- lol its not the red ring of death as the first answer said and even if it was that CAN be fixed.its obviously something wrong with the adapter (the box with the wire on it lol) and not the xbox itself so if your xbox is still under warranty then you can just send it back to get fixed.if not then you may need to invest in a new adapter/power cable
- Q: What are the cycles and requirements of the experimental project of the power cable experiment?
- Two should be phase line, generally in the three-phase loop corresponding to the color: A phase is yellow, B phase green, C phase red, neutral (that is, zero line) for the blue. If only in the single-phase loop only red and green when the default is red for the phase line, green for the zero line. But not necessarily, some electricians do not follow the requirements, the specific you have to use the pen to know what the
- Q: The specs say: 350 Watts, DC 12V, 100-240V. It is a Rackable server.Are there special / different power cables to use with servers than desktop PCs?Where can I find the power cable with the above specs. I tried OKorder with not much luck.
- Actually, There is no Different. The Point is make sure that the Cable to use for server is the Proper Cable to use for long term usage, and can plug properly to the Server.
- Q: The green light on the back of the power supply comes on when the power cable is plugged. also, every time i plug in the power cable, the fan on the power supply wants to spin, but it stops. The squeezing noise remains and i push the power button - nothing comes on.Before, it used to come on for a few seconds and then it will turn off by itself. I though it was a virus, so i restarted in safe mode to scan it. The PC stayed on for like 30 minutes and then it turned off by itself. But every since it doesn't wants to come on. Is the power supply gone? If so, how can still the green button comes on and the squeezing noise remains?well, I bought a power supply, and with the new power supply, nothing comes on - not even the squeezing noiseplease help me out! I need my PC! thanx in advanced!
- i believe the unique provide replaced into probable effective.... basically no longer completely 'firing' because the burden is in mistakes. a short or different mistakes on the feed area is undesirable. this way of means provide reacts to, and is managed through, the burden. hard to describe! At any price, the problem would nicely be contained in the workstation and under no circumstances the means provide itself.
- Q: My PC shuts down by itself and even if i push the power button, it won't start again. I have to unplug the power cable and plug it again and then push the power button to start again.... it will work for 30mins-1 hour, and then it will crush again.
- Do a virus scan..
Send your message to us
Plastic-insulated control cable Plastic-insulated control cable e
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords